Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

A motorized hand piece for injectable lenses

Identifieur interne : 001672 ( PascalFrancis/Corpus ); précédent : 001671; suivant : 001673

A motorized hand piece for injectable lenses

Auteurs : A. Scialdone ; P. G. Gobbi ; R. Brancato

Source :

RBID : Pascal:97-0327893

Descripteurs français

English descriptors

Abstract

Foldable lenses represent a major breakthrough in the effort to achieve ever smaller incisions. The plate-haptic or "taco-style" lenses are folded and implanted by a device called an injector. Although customized for each manufacturer's lens, the injectors all have a common design principle: the intraocular lens (IOL) is folded within a funnel-like structure of the tip and is advanced by a plunger that pushes and delivers the lens. To maintain optimal hand stabilization and injector management, both hands are usually required. This does not leave a hand to help with IOL positioning. To improve handling, a simple, mechanized system has been created for a new injector system that allows the delivery of the plate-haptic lens with one hand, in a pen-like fashion.

Notice en format standard (ISO 2709)

Pour connaître la documentation sur le format Inist Standard.

pA  
A01 01  1    @0 1082-3069
A03   1    @0 Ophthalmic surg. lasers
A05       @2 28
A06       @2 6
A08 01  1  ENG  @1 A motorized hand piece for injectable lenses
A11 01  1    @1 SCIALDONE (A.)
A11 02  1    @1 GOBBI (P. G.)
A11 03  1    @1 BRANCATO (R.)
A14 01      @1 Department of Ophthalmology and Visual Science, Scientific Institute H. S. Raffaele, University of Milan @2 Milan @3 ITA @Z 1 aut. @Z 3 aut.
A14 02      @1 Laser Medicine Research, Scientific Institute H. S. Raffaele, University of Milan @2 Milan @3 ITA @Z 2 aut.
A20       @1 518-519
A21       @1 1997
A23 01      @0 ENG
A43 01      @1 INIST @2 14946 @5 354000061623670120
A44       @0 0000 @1 © 1997 INIST-CNRS. All rights reserved.
A47 01  1    @0 97-0327893
A60       @1 P
A61       @0 A
A64 01  1    @0 Ophthalmic surgery and lasers
A66 01      @0 USA
C01 01    ENG  @0 Foldable lenses represent a major breakthrough in the effort to achieve ever smaller incisions. The plate-haptic or "taco-style" lenses are folded and implanted by a device called an injector. Although customized for each manufacturer's lens, the injectors all have a common design principle: the intraocular lens (IOL) is folded within a funnel-like structure of the tip and is advanced by a plunger that pushes and delivers the lens. To maintain optimal hand stabilization and injector management, both hands are usually required. This does not leave a hand to help with IOL positioning. To improve handling, a simple, mechanized system has been created for a new injector system that allows the delivery of the plate-haptic lens with one hand, in a pen-like fashion.
C02 01  X    @0 002B25B
C03 01  X  FRE  @0 Lentille intraoculaire @5 01
C03 01  X  ENG  @0 Intraocular lens @5 01
C03 01  X  SPA  @0 Lente intraocular @5 01
C03 02  X  FRE  @0 Structure en voile plissé @5 02
C03 02  X  ENG  @0 Folded structure @5 02
C03 02  X  SPA  @0 Estructura plegada @5 02
C03 03  X  FRE  @0 Implantation @5 03
C03 03  X  ENG  @0 Implantation @5 03
C03 03  X  SPA  @0 Implantación @5 03
C03 04  X  FRE  @0 Injecteur @5 04
C03 04  X  ENG  @0 Injector @5 04
C03 04  X  SPA  @0 Inyector @5 04
C03 05  X  FRE  @0 Appareil @5 05
C03 05  X  ENG  @0 Apparatus @5 05
C03 05  X  SPA  @0 Aparato @5 05
C03 06  X  FRE  @0 Technique @5 07
C03 06  X  ENG  @0 Technique @5 07
C03 06  X  SPA  @0 Técnica @5 07
C03 07  X  FRE  @0 Homme @5 10
C03 07  X  ENG  @0 Human @5 10
C03 07  X  SPA  @0 Hombre @5 10
C07 01  X  FRE  @0 Chirurgie @5 37
C07 01  X  ENG  @0 Surgery @5 37
C07 01  X  SPA  @0 Cirugía @5 37
N21       @1 188

Format Inist (serveur)

NO : PASCAL 97-0327893 INIST
ET : A motorized hand piece for injectable lenses
AU : SCIALDONE (A.); GOBBI (P. G.); BRANCATO (R.)
AF : Department of Ophthalmology and Visual Science, Scientific Institute H. S. Raffaele, University of Milan/Milan/Italie (1 aut., 3 aut.); Laser Medicine Research, Scientific Institute H. S. Raffaele, University of Milan/Milan/Italie (2 aut.)
DT : Publication en série; Niveau analytique
SO : Ophthalmic surgery and lasers; ISSN 1082-3069; Etats-Unis; Da. 1997; Vol. 28; No. 6; Pp. 518-519
LA : Anglais
EA : Foldable lenses represent a major breakthrough in the effort to achieve ever smaller incisions. The plate-haptic or "taco-style" lenses are folded and implanted by a device called an injector. Although customized for each manufacturer's lens, the injectors all have a common design principle: the intraocular lens (IOL) is folded within a funnel-like structure of the tip and is advanced by a plunger that pushes and delivers the lens. To maintain optimal hand stabilization and injector management, both hands are usually required. This does not leave a hand to help with IOL positioning. To improve handling, a simple, mechanized system has been created for a new injector system that allows the delivery of the plate-haptic lens with one hand, in a pen-like fashion.
CC : 002B25B
FD : Lentille intraoculaire; Structure en voile plissé; Implantation; Injecteur; Appareil; Technique; Homme
FG : Chirurgie
ED : Intraocular lens; Folded structure; Implantation; Injector; Apparatus; Technique; Human
EG : Surgery
SD : Lente intraocular; Estructura plegada; Implantación; Inyector; Aparato; Técnica; Hombre
LO : INIST-14946.354000061623670120
ID : 97-0327893

Links to Exploration step

Pascal:97-0327893

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en" level="a">A motorized hand piece for injectable lenses</title>
<author>
<name sortKey="Scialdone, A" sort="Scialdone, A" uniqKey="Scialdone A" first="A." last="Scialdone">A. Scialdone</name>
<affiliation>
<inist:fA14 i1="01">
<s1>Department of Ophthalmology and Visual Science, Scientific Institute H. S. Raffaele, University of Milan</s1>
<s2>Milan</s2>
<s3>ITA</s3>
<sZ>1 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author>
<name sortKey="Gobbi, P G" sort="Gobbi, P G" uniqKey="Gobbi P" first="P. G." last="Gobbi">P. G. Gobbi</name>
<affiliation>
<inist:fA14 i1="02">
<s1>Laser Medicine Research, Scientific Institute H. S. Raffaele, University of Milan</s1>
<s2>Milan</s2>
<s3>ITA</s3>
<sZ>2 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author>
<name sortKey="Brancato, R" sort="Brancato, R" uniqKey="Brancato R" first="R." last="Brancato">R. Brancato</name>
<affiliation>
<inist:fA14 i1="01">
<s1>Department of Ophthalmology and Visual Science, Scientific Institute H. S. Raffaele, University of Milan</s1>
<s2>Milan</s2>
<s3>ITA</s3>
<sZ>1 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">INIST</idno>
<idno type="inist">97-0327893</idno>
<date when="1997">1997</date>
<idno type="stanalyst">PASCAL 97-0327893 INIST</idno>
<idno type="RBID">Pascal:97-0327893</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">001672</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a">A motorized hand piece for injectable lenses</title>
<author>
<name sortKey="Scialdone, A" sort="Scialdone, A" uniqKey="Scialdone A" first="A." last="Scialdone">A. Scialdone</name>
<affiliation>
<inist:fA14 i1="01">
<s1>Department of Ophthalmology and Visual Science, Scientific Institute H. S. Raffaele, University of Milan</s1>
<s2>Milan</s2>
<s3>ITA</s3>
<sZ>1 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author>
<name sortKey="Gobbi, P G" sort="Gobbi, P G" uniqKey="Gobbi P" first="P. G." last="Gobbi">P. G. Gobbi</name>
<affiliation>
<inist:fA14 i1="02">
<s1>Laser Medicine Research, Scientific Institute H. S. Raffaele, University of Milan</s1>
<s2>Milan</s2>
<s3>ITA</s3>
<sZ>2 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
<author>
<name sortKey="Brancato, R" sort="Brancato, R" uniqKey="Brancato R" first="R." last="Brancato">R. Brancato</name>
<affiliation>
<inist:fA14 i1="01">
<s1>Department of Ophthalmology and Visual Science, Scientific Institute H. S. Raffaele, University of Milan</s1>
<s2>Milan</s2>
<s3>ITA</s3>
<sZ>1 aut.</sZ>
<sZ>3 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
</analytic>
<series>
<title level="j" type="main">Ophthalmic surgery and lasers</title>
<title level="j" type="abbreviated">Ophthalmic surg. lasers</title>
<idno type="ISSN">1082-3069</idno>
<imprint>
<date when="1997">1997</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<title level="j" type="main">Ophthalmic surgery and lasers</title>
<title level="j" type="abbreviated">Ophthalmic surg. lasers</title>
<idno type="ISSN">1082-3069</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Apparatus</term>
<term>Folded structure</term>
<term>Human</term>
<term>Implantation</term>
<term>Injector</term>
<term>Intraocular lens</term>
<term>Technique</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Lentille intraoculaire</term>
<term>Structure en voile plissé</term>
<term>Implantation</term>
<term>Injecteur</term>
<term>Appareil</term>
<term>Technique</term>
<term>Homme</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Foldable lenses represent a major breakthrough in the effort to achieve ever smaller incisions. The plate-haptic or "taco-style" lenses are folded and implanted by a device called an injector. Although customized for each manufacturer's lens, the injectors all have a common design principle: the intraocular lens (IOL) is folded within a funnel-like structure of the tip and is advanced by a plunger that pushes and delivers the lens. To maintain optimal hand stabilization and injector management, both hands are usually required. This does not leave a hand to help with IOL positioning. To improve handling, a simple, mechanized system has been created for a new injector system that allows the delivery of the plate-haptic lens with one hand, in a pen-like fashion.</div>
</front>
</TEI>
<inist>
<standard h6="B">
<pA>
<fA01 i1="01" i2="1">
<s0>1082-3069</s0>
</fA01>
<fA03 i2="1">
<s0>Ophthalmic surg. lasers</s0>
</fA03>
<fA05>
<s2>28</s2>
</fA05>
<fA06>
<s2>6</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG">
<s1>A motorized hand piece for injectable lenses</s1>
</fA08>
<fA11 i1="01" i2="1">
<s1>SCIALDONE (A.)</s1>
</fA11>
<fA11 i1="02" i2="1">
<s1>GOBBI (P. G.)</s1>
</fA11>
<fA11 i1="03" i2="1">
<s1>BRANCATO (R.)</s1>
</fA11>
<fA14 i1="01">
<s1>Department of Ophthalmology and Visual Science, Scientific Institute H. S. Raffaele, University of Milan</s1>
<s2>Milan</s2>
<s3>ITA</s3>
<sZ>1 aut.</sZ>
<sZ>3 aut.</sZ>
</fA14>
<fA14 i1="02">
<s1>Laser Medicine Research, Scientific Institute H. S. Raffaele, University of Milan</s1>
<s2>Milan</s2>
<s3>ITA</s3>
<sZ>2 aut.</sZ>
</fA14>
<fA20>
<s1>518-519</s1>
</fA20>
<fA21>
<s1>1997</s1>
</fA21>
<fA23 i1="01">
<s0>ENG</s0>
</fA23>
<fA43 i1="01">
<s1>INIST</s1>
<s2>14946</s2>
<s5>354000061623670120</s5>
</fA43>
<fA44>
<s0>0000</s0>
<s1>© 1997 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA47 i1="01" i2="1">
<s0>97-0327893</s0>
</fA47>
<fA60>
<s1>P</s1>
</fA60>
<fA61>
<s0>A</s0>
</fA61>
<fA64 i1="01" i2="1">
<s0>Ophthalmic surgery and lasers</s0>
</fA64>
<fA66 i1="01">
<s0>USA</s0>
</fA66>
<fC01 i1="01" l="ENG">
<s0>Foldable lenses represent a major breakthrough in the effort to achieve ever smaller incisions. The plate-haptic or "taco-style" lenses are folded and implanted by a device called an injector. Although customized for each manufacturer's lens, the injectors all have a common design principle: the intraocular lens (IOL) is folded within a funnel-like structure of the tip and is advanced by a plunger that pushes and delivers the lens. To maintain optimal hand stabilization and injector management, both hands are usually required. This does not leave a hand to help with IOL positioning. To improve handling, a simple, mechanized system has been created for a new injector system that allows the delivery of the plate-haptic lens with one hand, in a pen-like fashion.</s0>
</fC01>
<fC02 i1="01" i2="X">
<s0>002B25B</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE">
<s0>Lentille intraoculaire</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG">
<s0>Intraocular lens</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA">
<s0>Lente intraocular</s0>
<s5>01</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE">
<s0>Structure en voile plissé</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG">
<s0>Folded structure</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA">
<s0>Estructura plegada</s0>
<s5>02</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE">
<s0>Implantation</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG">
<s0>Implantation</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA">
<s0>Implantación</s0>
<s5>03</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE">
<s0>Injecteur</s0>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG">
<s0>Injector</s0>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA">
<s0>Inyector</s0>
<s5>04</s5>
</fC03>
<fC03 i1="05" i2="X" l="FRE">
<s0>Appareil</s0>
<s5>05</s5>
</fC03>
<fC03 i1="05" i2="X" l="ENG">
<s0>Apparatus</s0>
<s5>05</s5>
</fC03>
<fC03 i1="05" i2="X" l="SPA">
<s0>Aparato</s0>
<s5>05</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE">
<s0>Technique</s0>
<s5>07</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG">
<s0>Technique</s0>
<s5>07</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA">
<s0>Técnica</s0>
<s5>07</s5>
</fC03>
<fC03 i1="07" i2="X" l="FRE">
<s0>Homme</s0>
<s5>10</s5>
</fC03>
<fC03 i1="07" i2="X" l="ENG">
<s0>Human</s0>
<s5>10</s5>
</fC03>
<fC03 i1="07" i2="X" l="SPA">
<s0>Hombre</s0>
<s5>10</s5>
</fC03>
<fC07 i1="01" i2="X" l="FRE">
<s0>Chirurgie</s0>
<s5>37</s5>
</fC07>
<fC07 i1="01" i2="X" l="ENG">
<s0>Surgery</s0>
<s5>37</s5>
</fC07>
<fC07 i1="01" i2="X" l="SPA">
<s0>Cirugía</s0>
<s5>37</s5>
</fC07>
<fN21>
<s1>188</s1>
</fN21>
</pA>
</standard>
<server>
<NO>PASCAL 97-0327893 INIST</NO>
<ET>A motorized hand piece for injectable lenses</ET>
<AU>SCIALDONE (A.); GOBBI (P. G.); BRANCATO (R.)</AU>
<AF>Department of Ophthalmology and Visual Science, Scientific Institute H. S. Raffaele, University of Milan/Milan/Italie (1 aut., 3 aut.); Laser Medicine Research, Scientific Institute H. S. Raffaele, University of Milan/Milan/Italie (2 aut.)</AF>
<DT>Publication en série; Niveau analytique</DT>
<SO>Ophthalmic surgery and lasers; ISSN 1082-3069; Etats-Unis; Da. 1997; Vol. 28; No. 6; Pp. 518-519</SO>
<LA>Anglais</LA>
<EA>Foldable lenses represent a major breakthrough in the effort to achieve ever smaller incisions. The plate-haptic or "taco-style" lenses are folded and implanted by a device called an injector. Although customized for each manufacturer's lens, the injectors all have a common design principle: the intraocular lens (IOL) is folded within a funnel-like structure of the tip and is advanced by a plunger that pushes and delivers the lens. To maintain optimal hand stabilization and injector management, both hands are usually required. This does not leave a hand to help with IOL positioning. To improve handling, a simple, mechanized system has been created for a new injector system that allows the delivery of the plate-haptic lens with one hand, in a pen-like fashion.</EA>
<CC>002B25B</CC>
<FD>Lentille intraoculaire; Structure en voile plissé; Implantation; Injecteur; Appareil; Technique; Homme</FD>
<FG>Chirurgie</FG>
<ED>Intraocular lens; Folded structure; Implantation; Injector; Apparatus; Technique; Human</ED>
<EG>Surgery</EG>
<SD>Lente intraocular; Estructura plegada; Implantación; Inyector; Aparato; Técnica; Hombre</SD>
<LO>INIST-14946.354000061623670120</LO>
<ID>97-0327893</ID>
</server>
</inist>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PascalFrancis/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001672 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Corpus/biblio.hfd -nk 001672 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PascalFrancis
   |étape=   Corpus
   |type=    RBID
   |clé=     Pascal:97-0327893
   |texte=   A motorized hand piece for injectable lenses
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024