Suture fixation of a foldable acrylic intraocular lens for ectopia lentis

Identifieur interne : 001295 ( PascalFrancis/Corpus ); précédent : 001294; suivant : 001296

Suture fixation of a foldable acrylic intraocular lens for ectopia lentis

Auteurs : Mark Packer ; I. Howard Fine ; Richard S. Hoffman

Source :

RBID : Pascal:02-0258721

Descripteurs français

English descriptors

Abstract

A 5-year-old boy with severe ectopia lentis had bilateral lensectomy and suture fixation of a foldable acrylic intraocular lens (IOL) through a 3.0 mm clear corneal incision. Sodium hyaluronate (Healon GV®) enhanced stability of the crystalline lens during aspiration and maintenance of the anterior chamber during passage of the needles through the ciliary sulcus. The haptic design of the single-piece AcrySof® (Alcon) IOL permitted secure fixation of the suture to the haptic. The patient experienced rapid visual rehabilitation, achieving an uncorrected visual acuity of 20/40 in both eyes.

Notice en format standard (ISO 2709)

Pour connaître la documentation sur le format Inist Standard.

pA  
A01 01  1    @0 0886-3350
A02 01      @0 JCSUEV
A03   1    @0 J. cataract refractive surg.
A05       @2 28
A06       @2 1
A08 01  1  ENG  @1 Suture fixation of a foldable acrylic intraocular lens for ectopia lentis
A11 01  1    @1 PACKER (Mark)
A11 02  1    @1 FINE (I. Howard)
A11 03  1    @1 HOFFMAN (Richard S.)
A20       @1 182-185
A21       @1 2002
A23 01      @0 ENG
A43 01      @1 INIST @2 20937 @5 354000094809070260
A44       @0 0000 @1 © 2002 INIST-CNRS. All rights reserved.
A45       @0 9 ref.
A47 01  1    @0 02-0258721
A60       @1 P @3 EC
A61       @0 A
A64 01  1    @0 Journal of cataract and refractive surgery
A66 01      @0 USA
C01 01    ENG  @0 A 5-year-old boy with severe ectopia lentis had bilateral lensectomy and suture fixation of a foldable acrylic intraocular lens (IOL) through a 3.0 mm clear corneal incision. Sodium hyaluronate (Healon GV®) enhanced stability of the crystalline lens during aspiration and maintenance of the anterior chamber during passage of the needles through the ciliary sulcus. The haptic design of the single-piece AcrySof® (Alcon) IOL permitted secure fixation of the suture to the haptic. The patient experienced rapid visual rehabilitation, achieving an uncorrected visual acuity of 20/40 in both eyes.
C02 01  X    @0 002B25B
C03 01  X  FRE  @0 Ectopie @5 01
C03 01  X  ENG  @0 Ectopia @5 01
C03 01  X  SPA  @0 Ectopia @5 01
C03 02  X  FRE  @0 Cristallin @5 02
C03 02  X  ENG  @0 Lens @5 02
C03 02  X  SPA  @0 Cristalino @5 02
C03 03  X  FRE  @0 Traitement @5 03
C03 03  X  ENG  @0 Treatment @5 03
C03 03  X  SPA  @0 Tratamiento @5 03
C03 04  X  FRE  @0 Extraction @5 04
C03 04  X  ENG  @0 Extraction @5 04
C03 04  X  SPA  @0 Extracción @5 04
C03 05  X  FRE  @0 Fixation @5 05
C03 05  X  ENG  @0 Fixation @5 05
C03 05  X  SPA  @0 Fijación @5 05
C03 06  X  FRE  @0 Suture chirurgicale @5 06
C03 06  X  ENG  @0 Suturation @5 06
C03 06  X  SPA  @0 Sutura quirúrgica @5 06
C03 07  X  FRE  @0 Lentille intraoculaire @5 07
C03 07  X  ENG  @0 Intraocular lens @5 07
C03 07  X  SPA  @0 Lente intraocular @5 07
C03 08  X  FRE  @0 Acrylique dérivé polymère @2 NK @5 08
C03 08  X  ENG  @0 Acrylic polymer @2 NK @5 08
C03 08  X  SPA  @0 Acrilico derivado polímero @2 NK @5 08
C03 09  X  FRE  @0 Biomatériau @5 09
C03 09  X  ENG  @0 Biomaterial @5 09
C03 09  X  SPA  @0 Biomaterial @5 09
C03 10  X  FRE  @0 Structure en voile plissé @5 10
C03 10  X  ENG  @0 Folded structure @5 10
C03 10  X  SPA  @0 Estructura plegada @5 10
C03 11  X  FRE  @0 Technique @5 11
C03 11  X  ENG  @0 Technique @5 11
C03 11  X  SPA  @0 Técnica @5 11
C03 12  X  FRE  @0 Oeil @5 12
C03 12  X  ENG  @0 Eye @5 12
C03 12  X  SPA  @0 Ojo @5 12
C03 13  X  FRE  @0 Etude cas @5 13
C03 13  X  ENG  @0 Case study @5 13
C03 13  X  SPA  @0 Estudio caso @5 13
C03 14  X  FRE  @0 Enfant @5 17
C03 14  X  ENG  @0 Child @5 17
C03 14  X  SPA  @0 Niño @5 17
C07 01  X  FRE  @0 Homme
C07 01  X  ENG  @0 Human
C07 01  X  SPA  @0 Hombre
C07 02  X  FRE  @0 Oeil pathologie @5 37
C07 02  X  ENG  @0 Eye disease @5 37
C07 02  X  SPA  @0 Ojo patología @5 37
C07 03  X  FRE  @0 Malformation @5 38
C07 03  X  ENG  @0 Malformation @5 38
C07 03  X  SPA  @0 Malformación @5 38
C07 04  X  FRE  @0 Maladie congénitale @5 39
C07 04  X  ENG  @0 Congenital disease @5 39
C07 04  X  SPA  @0 Enfermedad congénita @5 39
C07 05  X  FRE  @0 Cristallin pathologie @5 40
C07 05  X  ENG  @0 Lens disease @5 40
C07 05  X  SPA  @0 Cristalino patología @5 40
C07 06  X  FRE  @0 Chirurgie @5 45
C07 06  X  ENG  @0 Surgery @5 45
C07 06  X  SPA  @0 Cirugía @5 45
N21       @1 154
N82       @1 PSI

Format Inist (serveur)

NO : PASCAL 02-0258721 INIST
ET : Suture fixation of a foldable acrylic intraocular lens for ectopia lentis
AU : PACKER (Mark); FINE (I. Howard); HOFFMAN (Richard S.)
DT : Publication en série; Etude de cas, cas et faits cliniques; Niveau analytique
SO : Journal of cataract and refractive surgery; ISSN 0886-3350; Coden JCSUEV; Etats-Unis; Da. 2002; Vol. 28; No. 1; Pp. 182-185; Bibl. 9 ref.
LA : Anglais
EA : A 5-year-old boy with severe ectopia lentis had bilateral lensectomy and suture fixation of a foldable acrylic intraocular lens (IOL) through a 3.0 mm clear corneal incision. Sodium hyaluronate (Healon GV®) enhanced stability of the crystalline lens during aspiration and maintenance of the anterior chamber during passage of the needles through the ciliary sulcus. The haptic design of the single-piece AcrySof® (Alcon) IOL permitted secure fixation of the suture to the haptic. The patient experienced rapid visual rehabilitation, achieving an uncorrected visual acuity of 20/40 in both eyes.
CC : 002B25B
FD : Ectopie; Cristallin; Traitement; Extraction; Fixation; Suture chirurgicale; Lentille intraoculaire; Acrylique dérivé polymère; Biomatériau; Structure en voile plissé; Technique; Oeil; Etude cas; Enfant
FG : Homme; Oeil pathologie; Malformation; Maladie congénitale; Cristallin pathologie; Chirurgie
ED : Ectopia; Lens; Treatment; Extraction; Fixation; Suturation; Intraocular lens; Acrylic polymer; Biomaterial; Folded structure; Technique; Eye; Case study; Child
EG : Human; Eye disease; Malformation; Congenital disease; Lens disease; Surgery
SD : Ectopia; Cristalino; Tratamiento; Extracción; Fijación; Sutura quirúrgica; Lente intraocular; Acrilico derivado polímero; Biomaterial; Estructura plegada; Técnica; Ojo; Estudio caso; Niño
LO : INIST-20937.354000094809070260
ID : 02-0258721

Links to Exploration step

Pascal:02-0258721

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en" level="a">Suture fixation of a foldable acrylic intraocular lens for ectopia lentis</title>
<author>
<name sortKey="Packer, Mark" sort="Packer, Mark" uniqKey="Packer M" first="Mark" last="Packer">Mark Packer</name>
<affiliation>
<wicri:noCountry>no AF</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Fine, I Howard" sort="Fine, I Howard" uniqKey="Fine I" first="I. Howard" last="Fine">I. Howard Fine</name>
<affiliation>
<wicri:noCountry>no AF</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Hoffman, Richard S" sort="Hoffman, Richard S" uniqKey="Hoffman R" first="Richard S." last="Hoffman">Richard S. Hoffman</name>
<affiliation>
<wicri:noCountry>no AF</wicri:noCountry>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">INIST</idno>
<idno type="inist">02-0258721</idno>
<date when="2002">2002</date>
<idno type="stanalyst">PASCAL 02-0258721 INIST</idno>
<idno type="RBID">Pascal:02-0258721</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">001295</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a">Suture fixation of a foldable acrylic intraocular lens for ectopia lentis</title>
<author>
<name sortKey="Packer, Mark" sort="Packer, Mark" uniqKey="Packer M" first="Mark" last="Packer">Mark Packer</name>
<affiliation>
<wicri:noCountry>no AF</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Fine, I Howard" sort="Fine, I Howard" uniqKey="Fine I" first="I. Howard" last="Fine">I. Howard Fine</name>
<affiliation>
<wicri:noCountry>no AF</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Hoffman, Richard S" sort="Hoffman, Richard S" uniqKey="Hoffman R" first="Richard S." last="Hoffman">Richard S. Hoffman</name>
<affiliation>
<wicri:noCountry>no AF</wicri:noCountry>
</affiliation>
</author>
</analytic>
<series>
<title level="j" type="main">Journal of cataract and refractive surgery</title>
<title level="j" type="abbreviated">J. cataract refractive surg.</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="2002">2002</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<title level="j" type="main">Journal of cataract and refractive surgery</title>
<title level="j" type="abbreviated">J. cataract refractive surg.</title>
<idno type="ISSN">0886-3350</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Acrylic polymer</term>
<term>Biomaterial</term>
<term>Case study</term>
<term>Child</term>
<term>Ectopia</term>
<term>Extraction</term>
<term>Eye</term>
<term>Fixation</term>
<term>Folded structure</term>
<term>Intraocular lens</term>
<term>Lens</term>
<term>Suturation</term>
<term>Technique</term>
<term>Treatment</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Ectopie</term>
<term>Cristallin</term>
<term>Traitement</term>
<term>Extraction</term>
<term>Fixation</term>
<term>Suture chirurgicale</term>
<term>Lentille intraoculaire</term>
<term>Acrylique dérivé polymère</term>
<term>Biomatériau</term>
<term>Structure en voile plissé</term>
<term>Technique</term>
<term>Oeil</term>
<term>Etude cas</term>
<term>Enfant</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">A 5-year-old boy with severe ectopia lentis had bilateral lensectomy and suture fixation of a foldable acrylic intraocular lens (IOL) through a 3.0 mm clear corneal incision. Sodium hyaluronate (Healon GV®) enhanced stability of the crystalline lens during aspiration and maintenance of the anterior chamber during passage of the needles through the ciliary sulcus. The haptic design of the single-piece AcrySof® (Alcon) IOL permitted secure fixation of the suture to the haptic. The patient experienced rapid visual rehabilitation, achieving an uncorrected visual acuity of 20/40 in both eyes.</div>
</front>
</TEI>
<inist>
<standard h6="B">
<pA>
<fA01 i1="01" i2="1">
<s0>0886-3350</s0>
</fA01>
<fA02 i1="01">
<s0>JCSUEV</s0>
</fA02>
<fA03 i2="1">
<s0>J. cataract refractive surg.</s0>
</fA03>
<fA05>
<s2>28</s2>
</fA05>
<fA06>
<s2>1</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG">
<s1>Suture fixation of a foldable acrylic intraocular lens for ectopia lentis</s1>
</fA08>
<fA11 i1="01" i2="1">
<s1>PACKER (Mark)</s1>
</fA11>
<fA11 i1="02" i2="1">
<s1>FINE (I. Howard)</s1>
</fA11>
<fA11 i1="03" i2="1">
<s1>HOFFMAN (Richard S.)</s1>
</fA11>
<fA20>
<s1>182-185</s1>
</fA20>
<fA21>
<s1>2002</s1>
</fA21>
<fA23 i1="01">
<s0>ENG</s0>
</fA23>
<fA43 i1="01">
<s1>INIST</s1>
<s2>20937</s2>
<s5>354000094809070260</s5>
</fA43>
<fA44>
<s0>0000</s0>
<s1>© 2002 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45>
<s0>9 ref.</s0>
</fA45>
<fA47 i1="01" i2="1">
<s0>02-0258721</s0>
</fA47>
<fA60>
<s1>P</s1>
<s3>EC</s3>
</fA60>
<fA61>
<s0>A</s0>
</fA61>
<fA64 i1="01" i2="1">
<s0>Journal of cataract and refractive surgery</s0>
</fA64>
<fA66 i1="01">
<s0>USA</s0>
</fA66>
<fC01 i1="01" l="ENG">
<s0>A 5-year-old boy with severe ectopia lentis had bilateral lensectomy and suture fixation of a foldable acrylic intraocular lens (IOL) through a 3.0 mm clear corneal incision. Sodium hyaluronate (Healon GV®) enhanced stability of the crystalline lens during aspiration and maintenance of the anterior chamber during passage of the needles through the ciliary sulcus. The haptic design of the single-piece AcrySof® (Alcon) IOL permitted secure fixation of the suture to the haptic. The patient experienced rapid visual rehabilitation, achieving an uncorrected visual acuity of 20/40 in both eyes.</s0>
</fC01>
<fC02 i1="01" i2="X">
<s0>002B25B</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE">
<s0>Ectopie</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG">
<s0>Ectopia</s0>
<s5>01</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA">
<s0>Ectopia</s0>
<s5>01</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE">
<s0>Cristallin</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG">
<s0>Lens</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA">
<s0>Cristalino</s0>
<s5>02</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE">
<s0>Traitement</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG">
<s0>Treatment</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA">
<s0>Tratamiento</s0>
<s5>03</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE">
<s0>Extraction</s0>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG">
<s0>Extraction</s0>
<s5>04</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA">
<s0>Extracción</s0>
<s5>04</s5>
</fC03>
<fC03 i1="05" i2="X" l="FRE">
<s0>Fixation</s0>
<s5>05</s5>
</fC03>
<fC03 i1="05" i2="X" l="ENG">
<s0>Fixation</s0>
<s5>05</s5>
</fC03>
<fC03 i1="05" i2="X" l="SPA">
<s0>Fijación</s0>
<s5>05</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE">
<s0>Suture chirurgicale</s0>
<s5>06</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG">
<s0>Suturation</s0>
<s5>06</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA">
<s0>Sutura quirúrgica</s0>
<s5>06</s5>
</fC03>
<fC03 i1="07" i2="X" l="FRE">
<s0>Lentille intraoculaire</s0>
<s5>07</s5>
</fC03>
<fC03 i1="07" i2="X" l="ENG">
<s0>Intraocular lens</s0>
<s5>07</s5>
</fC03>
<fC03 i1="07" i2="X" l="SPA">
<s0>Lente intraocular</s0>
<s5>07</s5>
</fC03>
<fC03 i1="08" i2="X" l="FRE">
<s0>Acrylique dérivé polymère</s0>
<s2>NK</s2>
<s5>08</s5>
</fC03>
<fC03 i1="08" i2="X" l="ENG">
<s0>Acrylic polymer</s0>
<s2>NK</s2>
<s5>08</s5>
</fC03>
<fC03 i1="08" i2="X" l="SPA">
<s0>Acrilico derivado polímero</s0>
<s2>NK</s2>
<s5>08</s5>
</fC03>
<fC03 i1="09" i2="X" l="FRE">
<s0>Biomatériau</s0>
<s5>09</s5>
</fC03>
<fC03 i1="09" i2="X" l="ENG">
<s0>Biomaterial</s0>
<s5>09</s5>
</fC03>
<fC03 i1="09" i2="X" l="SPA">
<s0>Biomaterial</s0>
<s5>09</s5>
</fC03>
<fC03 i1="10" i2="X" l="FRE">
<s0>Structure en voile plissé</s0>
<s5>10</s5>
</fC03>
<fC03 i1="10" i2="X" l="ENG">
<s0>Folded structure</s0>
<s5>10</s5>
</fC03>
<fC03 i1="10" i2="X" l="SPA">
<s0>Estructura plegada</s0>
<s5>10</s5>
</fC03>
<fC03 i1="11" i2="X" l="FRE">
<s0>Technique</s0>
<s5>11</s5>
</fC03>
<fC03 i1="11" i2="X" l="ENG">
<s0>Technique</s0>
<s5>11</s5>
</fC03>
<fC03 i1="11" i2="X" l="SPA">
<s0>Técnica</s0>
<s5>11</s5>
</fC03>
<fC03 i1="12" i2="X" l="FRE">
<s0>Oeil</s0>
<s5>12</s5>
</fC03>
<fC03 i1="12" i2="X" l="ENG">
<s0>Eye</s0>
<s5>12</s5>
</fC03>
<fC03 i1="12" i2="X" l="SPA">
<s0>Ojo</s0>
<s5>12</s5>
</fC03>
<fC03 i1="13" i2="X" l="FRE">
<s0>Etude cas</s0>
<s5>13</s5>
</fC03>
<fC03 i1="13" i2="X" l="ENG">
<s0>Case study</s0>
<s5>13</s5>
</fC03>
<fC03 i1="13" i2="X" l="SPA">
<s0>Estudio caso</s0>
<s5>13</s5>
</fC03>
<fC03 i1="14" i2="X" l="FRE">
<s0>Enfant</s0>
<s5>17</s5>
</fC03>
<fC03 i1="14" i2="X" l="ENG">
<s0>Child</s0>
<s5>17</s5>
</fC03>
<fC03 i1="14" i2="X" l="SPA">
<s0>Niño</s0>
<s5>17</s5>
</fC03>
<fC07 i1="01" i2="X" l="FRE">
<s0>Homme</s0>
</fC07>
<fC07 i1="01" i2="X" l="ENG">
<s0>Human</s0>
</fC07>
<fC07 i1="01" i2="X" l="SPA">
<s0>Hombre</s0>
</fC07>
<fC07 i1="02" i2="X" l="FRE">
<s0>Oeil pathologie</s0>
<s5>37</s5>
</fC07>
<fC07 i1="02" i2="X" l="ENG">
<s0>Eye disease</s0>
<s5>37</s5>
</fC07>
<fC07 i1="02" i2="X" l="SPA">
<s0>Ojo patología</s0>
<s5>37</s5>
</fC07>
<fC07 i1="03" i2="X" l="FRE">
<s0>Malformation</s0>
<s5>38</s5>
</fC07>
<fC07 i1="03" i2="X" l="ENG">
<s0>Malformation</s0>
<s5>38</s5>
</fC07>
<fC07 i1="03" i2="X" l="SPA">
<s0>Malformación</s0>
<s5>38</s5>
</fC07>
<fC07 i1="04" i2="X" l="FRE">
<s0>Maladie congénitale</s0>
<s5>39</s5>
</fC07>
<fC07 i1="04" i2="X" l="ENG">
<s0>Congenital disease</s0>
<s5>39</s5>
</fC07>
<fC07 i1="04" i2="X" l="SPA">
<s0>Enfermedad congénita</s0>
<s5>39</s5>
</fC07>
<fC07 i1="05" i2="X" l="FRE">
<s0>Cristallin pathologie</s0>
<s5>40</s5>
</fC07>
<fC07 i1="05" i2="X" l="ENG">
<s0>Lens disease</s0>
<s5>40</s5>
</fC07>
<fC07 i1="05" i2="X" l="SPA">
<s0>Cristalino patología</s0>
<s5>40</s5>
</fC07>
<fC07 i1="06" i2="X" l="FRE">
<s0>Chirurgie</s0>
<s5>45</s5>
</fC07>
<fC07 i1="06" i2="X" l="ENG">
<s0>Surgery</s0>
<s5>45</s5>
</fC07>
<fC07 i1="06" i2="X" l="SPA">
<s0>Cirugía</s0>
<s5>45</s5>
</fC07>
<fN21>
<s1>154</s1>
</fN21>
<fN82>
<s1>PSI</s1>
</fN82>
</pA>
</standard>
<server>
<NO>PASCAL 02-0258721 INIST</NO>
<ET>Suture fixation of a foldable acrylic intraocular lens for ectopia lentis</ET>
<AU>PACKER (Mark); FINE (I. Howard); HOFFMAN (Richard S.)</AU>
<DT>Publication en série; Etude de cas, cas et faits cliniques; Niveau analytique</DT>
<SO>Journal of cataract and refractive surgery; ISSN 0886-3350; Coden JCSUEV; Etats-Unis; Da. 2002; Vol. 28; No. 1; Pp. 182-185; Bibl. 9 ref.</SO>
<LA>Anglais</LA>
<EA>A 5-year-old boy with severe ectopia lentis had bilateral lensectomy and suture fixation of a foldable acrylic intraocular lens (IOL) through a 3.0 mm clear corneal incision. Sodium hyaluronate (Healon GV®) enhanced stability of the crystalline lens during aspiration and maintenance of the anterior chamber during passage of the needles through the ciliary sulcus. The haptic design of the single-piece AcrySof® (Alcon) IOL permitted secure fixation of the suture to the haptic. The patient experienced rapid visual rehabilitation, achieving an uncorrected visual acuity of 20/40 in both eyes.</EA>
<CC>002B25B</CC>
<FD>Ectopie; Cristallin; Traitement; Extraction; Fixation; Suture chirurgicale; Lentille intraoculaire; Acrylique dérivé polymère; Biomatériau; Structure en voile plissé; Technique; Oeil; Etude cas; Enfant</FD>
<FG>Homme; Oeil pathologie; Malformation; Maladie congénitale; Cristallin pathologie; Chirurgie</FG>
<ED>Ectopia; Lens; Treatment; Extraction; Fixation; Suturation; Intraocular lens; Acrylic polymer; Biomaterial; Folded structure; Technique; Eye; Case study; Child</ED>
<EG>Human; Eye disease; Malformation; Congenital disease; Lens disease; Surgery</EG>
<SD>Ectopia; Cristalino; Tratamiento; Extracción; Fijación; Sutura quirúrgica; Lente intraocular; Acrilico derivado polímero; Biomaterial; Estructura plegada; Técnica; Ojo; Estudio caso; Niño</SD>
<LO>INIST-20937.354000094809070260</LO>
<ID>02-0258721</ID>
</server>
</inist>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PascalFrancis/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001295 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Corpus/biblio.hfd -nk 001295 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PascalFrancis
   |étape=   Corpus
   |type=    RBID
   |clé=     Pascal:02-0258721
   |texte=   Suture fixation of a foldable acrylic intraocular lens for ectopia lentis
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024