Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Using the lens haptic plane concept and thick-lens ray tracing to calculate intraocular lens power

Identifieur interne : 000F94 ( PascalFrancis/Corpus ); précédent : 000F93; suivant : 000F95

Using the lens haptic plane concept and thick-lens ray tracing to calculate intraocular lens power

Auteurs : Sverker Norrby

Source :

RBID : Pascal:04-0296953

Descripteurs français

English descriptors

Abstract

Purpose: To develop a methodology for intraocular lens (IOL) power calculation in which the task of predicting the postoperative position of the IOL Is separated from the calculation itself. Setting: Pharmacia, Groningen, The Netherlands. Methods: The minimum biometry input needed for IOL power calculation is the mean anterior corneal radius and axial length of the eye. The lens haptic plane (LHP) is the plane where the IOL haptics make contact with eye tissue. It is an anatomical site (eg, the equator of the capsular bag) and is independent of the IOL model. The position of the IOL optic in relation to the LHP is determined from the exact design of the IOL. Gullstrand's eye model is adopted to obtain the posterior corneal radius, thickness of the cornea, and refractive indices of the eye media. Thick-lens ray tracing in the paraxial limit is used for the optical calculation. Results: A spreadsheet is given for the calculation. Conclusions: The methodology developed allows for IOL power calculation from first principles (ie, using true physical distances, radii, and refractive indices as input for the optical calculation).

Notice en format standard (ISO 2709)

Pour connaître la documentation sur le format Inist Standard.

pA  
A01 01  1    @0 0886-3350
A02 01      @0 JCSUEV
A03   1    @0 J. cataract refractive surg.
A05       @2 30
A06       @2 5
A08 01  1  ENG  @1 Using the lens haptic plane concept and thick-lens ray tracing to calculate intraocular lens power
A11 01  1    @1 NORRBY (Sverker)
A14 01      @1 Pharmacia @2 Groningen @3 NLD @Z 1 aut.
A20       @1 1000-1005
A21       @1 2004
A23 01      @0 ENG
A43 01      @1 INIST @2 20937 @5 354000114546840080
A44       @0 0000 @1 © 2004 INIST-CNRS. All rights reserved.
A45       @0 28 ref.
A47 01  1    @0 04-0296953
A60       @1 P
A61       @0 A
A64 01  1    @0 Journal of cataract and refractive surgery
A66 01      @0 USA
C01 01    ENG  @0 Purpose: To develop a methodology for intraocular lens (IOL) power calculation in which the task of predicting the postoperative position of the IOL Is separated from the calculation itself. Setting: Pharmacia, Groningen, The Netherlands. Methods: The minimum biometry input needed for IOL power calculation is the mean anterior corneal radius and axial length of the eye. The lens haptic plane (LHP) is the plane where the IOL haptics make contact with eye tissue. It is an anatomical site (eg, the equator of the capsular bag) and is independent of the IOL model. The position of the IOL optic in relation to the LHP is determined from the exact design of the IOL. Gullstrand's eye model is adopted to obtain the posterior corneal radius, thickness of the cornea, and refractive indices of the eye media. Thick-lens ray tracing in the paraxial limit is used for the optical calculation. Results: A spreadsheet is given for the calculation. Conclusions: The methodology developed allows for IOL power calculation from first principles (ie, using true physical distances, radii, and refractive indices as input for the optical calculation).
C02 01  X    @0 002B25B
C03 01  X  FRE  @0 Cristallin @5 02
C03 01  X  ENG  @0 Lens @5 02
C03 01  X  SPA  @0 Cristalino @5 02
C03 02  X  FRE  @0 Plan @5 03
C03 02  X  ENG  @0 Plane @5 03
C03 02  X  SPA  @0 Plano @5 03
C03 03  X  FRE  @0 Lentille épaisse @5 05
C03 03  X  ENG  @0 Thick lens @5 05
C03 03  X  SPA  @0 Lente grueso @5 05
C03 04  X  FRE  @0 Tracé rayon @5 06
C03 04  X  ENG  @0 Ray tracing @5 06
C03 04  X  SPA  @0 Trazado rayos @5 06
C03 05  X  FRE  @0 Lentille intraoculaire @5 08
C03 05  X  ENG  @0 Intraocular lens @5 08
C03 05  X  SPA  @0 Lente intraocular @5 08
C03 06  X  FRE  @0 Puissance @5 09
C03 06  X  ENG  @0 Power @5 09
C03 06  X  SPA  @0 Potencia @5 09
C03 07  X  FRE  @0 Chirurgie @5 11
C03 07  X  ENG  @0 Surgery @5 11
C03 07  X  SPA  @0 Cirugía @5 11
C03 08  X  FRE  @0 Ophtalmologie @5 12
C03 08  X  ENG  @0 Ophthalmology @5 12
C03 08  X  SPA  @0 Oftalmología @5 12
C03 09  X  FRE  @0 Traitement @5 25
C03 09  X  ENG  @0 Treatment @5 25
C03 09  X  SPA  @0 Tratamiento @5 25
N21       @1 180
N44 01      @1 OTO
N82       @1 OTO

Format Inist (serveur)

NO : PASCAL 04-0296953 INIST
ET : Using the lens haptic plane concept and thick-lens ray tracing to calculate intraocular lens power
AU : NORRBY (Sverker)
AF : Pharmacia/Groningen/Pays-Bas (1 aut.)
DT : Publication en série; Niveau analytique
SO : Journal of cataract and refractive surgery; ISSN 0886-3350; Coden JCSUEV; Etats-Unis; Da. 2004; Vol. 30; No. 5; Pp. 1000-1005; Bibl. 28 ref.
LA : Anglais
EA : Purpose: To develop a methodology for intraocular lens (IOL) power calculation in which the task of predicting the postoperative position of the IOL Is separated from the calculation itself. Setting: Pharmacia, Groningen, The Netherlands. Methods: The minimum biometry input needed for IOL power calculation is the mean anterior corneal radius and axial length of the eye. The lens haptic plane (LHP) is the plane where the IOL haptics make contact with eye tissue. It is an anatomical site (eg, the equator of the capsular bag) and is independent of the IOL model. The position of the IOL optic in relation to the LHP is determined from the exact design of the IOL. Gullstrand's eye model is adopted to obtain the posterior corneal radius, thickness of the cornea, and refractive indices of the eye media. Thick-lens ray tracing in the paraxial limit is used for the optical calculation. Results: A spreadsheet is given for the calculation. Conclusions: The methodology developed allows for IOL power calculation from first principles (ie, using true physical distances, radii, and refractive indices as input for the optical calculation).
CC : 002B25B
FD : Cristallin; Plan; Lentille épaisse; Tracé rayon; Lentille intraoculaire; Puissance; Chirurgie; Ophtalmologie; Traitement
ED : Lens; Plane; Thick lens; Ray tracing; Intraocular lens; Power; Surgery; Ophthalmology; Treatment
SD : Cristalino; Plano; Lente grueso; Trazado rayos; Lente intraocular; Potencia; Cirugía; Oftalmología; Tratamiento
LO : INIST-20937.354000114546840080
ID : 04-0296953

Links to Exploration step

Pascal:04-0296953

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en" level="a">Using the lens haptic plane concept and thick-lens ray tracing to calculate intraocular lens power</title>
<author>
<name sortKey="Norrby, Sverker" sort="Norrby, Sverker" uniqKey="Norrby S" first="Sverker" last="Norrby">Sverker Norrby</name>
<affiliation>
<inist:fA14 i1="01">
<s1>Pharmacia</s1>
<s2>Groningen</s2>
<s3>NLD</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">INIST</idno>
<idno type="inist">04-0296953</idno>
<date when="2004">2004</date>
<idno type="stanalyst">PASCAL 04-0296953 INIST</idno>
<idno type="RBID">Pascal:04-0296953</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000F94</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a">Using the lens haptic plane concept and thick-lens ray tracing to calculate intraocular lens power</title>
<author>
<name sortKey="Norrby, Sverker" sort="Norrby, Sverker" uniqKey="Norrby S" first="Sverker" last="Norrby">Sverker Norrby</name>
<affiliation>
<inist:fA14 i1="01">
<s1>Pharmacia</s1>
<s2>Groningen</s2>
<s3>NLD</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
</affiliation>
</author>
</analytic>
<series>
<title level="j" type="main">Journal of cataract and refractive surgery</title>
<title level="j" type="abbreviated">J. cataract refractive surg.</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="2004">2004</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<title level="j" type="main">Journal of cataract and refractive surgery</title>
<title level="j" type="abbreviated">J. cataract refractive surg.</title>
<idno type="ISSN">0886-3350</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Intraocular lens</term>
<term>Lens</term>
<term>Ophthalmology</term>
<term>Plane</term>
<term>Power</term>
<term>Ray tracing</term>
<term>Surgery</term>
<term>Thick lens</term>
<term>Treatment</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Cristallin</term>
<term>Plan</term>
<term>Lentille épaisse</term>
<term>Tracé rayon</term>
<term>Lentille intraoculaire</term>
<term>Puissance</term>
<term>Chirurgie</term>
<term>Ophtalmologie</term>
<term>Traitement</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Purpose: To develop a methodology for intraocular lens (IOL) power calculation in which the task of predicting the postoperative position of the IOL Is separated from the calculation itself. Setting: Pharmacia, Groningen, The Netherlands. Methods: The minimum biometry input needed for IOL power calculation is the mean anterior corneal radius and axial length of the eye. The lens haptic plane (LHP) is the plane where the IOL haptics make contact with eye tissue. It is an anatomical site (eg, the equator of the capsular bag) and is independent of the IOL model. The position of the IOL optic in relation to the LHP is determined from the exact design of the IOL. Gullstrand's eye model is adopted to obtain the posterior corneal radius, thickness of the cornea, and refractive indices of the eye media. Thick-lens ray tracing in the paraxial limit is used for the optical calculation. Results: A spreadsheet is given for the calculation. Conclusions: The methodology developed allows for IOL power calculation from first principles (ie, using true physical distances, radii, and refractive indices as input for the optical calculation).</div>
</front>
</TEI>
<inist>
<standard h6="B">
<pA>
<fA01 i1="01" i2="1">
<s0>0886-3350</s0>
</fA01>
<fA02 i1="01">
<s0>JCSUEV</s0>
</fA02>
<fA03 i2="1">
<s0>J. cataract refractive surg.</s0>
</fA03>
<fA05>
<s2>30</s2>
</fA05>
<fA06>
<s2>5</s2>
</fA06>
<fA08 i1="01" i2="1" l="ENG">
<s1>Using the lens haptic plane concept and thick-lens ray tracing to calculate intraocular lens power</s1>
</fA08>
<fA11 i1="01" i2="1">
<s1>NORRBY (Sverker)</s1>
</fA11>
<fA14 i1="01">
<s1>Pharmacia</s1>
<s2>Groningen</s2>
<s3>NLD</s3>
<sZ>1 aut.</sZ>
</fA14>
<fA20>
<s1>1000-1005</s1>
</fA20>
<fA21>
<s1>2004</s1>
</fA21>
<fA23 i1="01">
<s0>ENG</s0>
</fA23>
<fA43 i1="01">
<s1>INIST</s1>
<s2>20937</s2>
<s5>354000114546840080</s5>
</fA43>
<fA44>
<s0>0000</s0>
<s1>© 2004 INIST-CNRS. All rights reserved.</s1>
</fA44>
<fA45>
<s0>28 ref.</s0>
</fA45>
<fA47 i1="01" i2="1">
<s0>04-0296953</s0>
</fA47>
<fA60>
<s1>P</s1>
</fA60>
<fA61>
<s0>A</s0>
</fA61>
<fA64 i1="01" i2="1">
<s0>Journal of cataract and refractive surgery</s0>
</fA64>
<fA66 i1="01">
<s0>USA</s0>
</fA66>
<fC01 i1="01" l="ENG">
<s0>Purpose: To develop a methodology for intraocular lens (IOL) power calculation in which the task of predicting the postoperative position of the IOL Is separated from the calculation itself. Setting: Pharmacia, Groningen, The Netherlands. Methods: The minimum biometry input needed for IOL power calculation is the mean anterior corneal radius and axial length of the eye. The lens haptic plane (LHP) is the plane where the IOL haptics make contact with eye tissue. It is an anatomical site (eg, the equator of the capsular bag) and is independent of the IOL model. The position of the IOL optic in relation to the LHP is determined from the exact design of the IOL. Gullstrand's eye model is adopted to obtain the posterior corneal radius, thickness of the cornea, and refractive indices of the eye media. Thick-lens ray tracing in the paraxial limit is used for the optical calculation. Results: A spreadsheet is given for the calculation. Conclusions: The methodology developed allows for IOL power calculation from first principles (ie, using true physical distances, radii, and refractive indices as input for the optical calculation).</s0>
</fC01>
<fC02 i1="01" i2="X">
<s0>002B25B</s0>
</fC02>
<fC03 i1="01" i2="X" l="FRE">
<s0>Cristallin</s0>
<s5>02</s5>
</fC03>
<fC03 i1="01" i2="X" l="ENG">
<s0>Lens</s0>
<s5>02</s5>
</fC03>
<fC03 i1="01" i2="X" l="SPA">
<s0>Cristalino</s0>
<s5>02</s5>
</fC03>
<fC03 i1="02" i2="X" l="FRE">
<s0>Plan</s0>
<s5>03</s5>
</fC03>
<fC03 i1="02" i2="X" l="ENG">
<s0>Plane</s0>
<s5>03</s5>
</fC03>
<fC03 i1="02" i2="X" l="SPA">
<s0>Plano</s0>
<s5>03</s5>
</fC03>
<fC03 i1="03" i2="X" l="FRE">
<s0>Lentille épaisse</s0>
<s5>05</s5>
</fC03>
<fC03 i1="03" i2="X" l="ENG">
<s0>Thick lens</s0>
<s5>05</s5>
</fC03>
<fC03 i1="03" i2="X" l="SPA">
<s0>Lente grueso</s0>
<s5>05</s5>
</fC03>
<fC03 i1="04" i2="X" l="FRE">
<s0>Tracé rayon</s0>
<s5>06</s5>
</fC03>
<fC03 i1="04" i2="X" l="ENG">
<s0>Ray tracing</s0>
<s5>06</s5>
</fC03>
<fC03 i1="04" i2="X" l="SPA">
<s0>Trazado rayos</s0>
<s5>06</s5>
</fC03>
<fC03 i1="05" i2="X" l="FRE">
<s0>Lentille intraoculaire</s0>
<s5>08</s5>
</fC03>
<fC03 i1="05" i2="X" l="ENG">
<s0>Intraocular lens</s0>
<s5>08</s5>
</fC03>
<fC03 i1="05" i2="X" l="SPA">
<s0>Lente intraocular</s0>
<s5>08</s5>
</fC03>
<fC03 i1="06" i2="X" l="FRE">
<s0>Puissance</s0>
<s5>09</s5>
</fC03>
<fC03 i1="06" i2="X" l="ENG">
<s0>Power</s0>
<s5>09</s5>
</fC03>
<fC03 i1="06" i2="X" l="SPA">
<s0>Potencia</s0>
<s5>09</s5>
</fC03>
<fC03 i1="07" i2="X" l="FRE">
<s0>Chirurgie</s0>
<s5>11</s5>
</fC03>
<fC03 i1="07" i2="X" l="ENG">
<s0>Surgery</s0>
<s5>11</s5>
</fC03>
<fC03 i1="07" i2="X" l="SPA">
<s0>Cirugía</s0>
<s5>11</s5>
</fC03>
<fC03 i1="08" i2="X" l="FRE">
<s0>Ophtalmologie</s0>
<s5>12</s5>
</fC03>
<fC03 i1="08" i2="X" l="ENG">
<s0>Ophthalmology</s0>
<s5>12</s5>
</fC03>
<fC03 i1="08" i2="X" l="SPA">
<s0>Oftalmología</s0>
<s5>12</s5>
</fC03>
<fC03 i1="09" i2="X" l="FRE">
<s0>Traitement</s0>
<s5>25</s5>
</fC03>
<fC03 i1="09" i2="X" l="ENG">
<s0>Treatment</s0>
<s5>25</s5>
</fC03>
<fC03 i1="09" i2="X" l="SPA">
<s0>Tratamiento</s0>
<s5>25</s5>
</fC03>
<fN21>
<s1>180</s1>
</fN21>
<fN44 i1="01">
<s1>OTO</s1>
</fN44>
<fN82>
<s1>OTO</s1>
</fN82>
</pA>
</standard>
<server>
<NO>PASCAL 04-0296953 INIST</NO>
<ET>Using the lens haptic plane concept and thick-lens ray tracing to calculate intraocular lens power</ET>
<AU>NORRBY (Sverker)</AU>
<AF>Pharmacia/Groningen/Pays-Bas (1 aut.)</AF>
<DT>Publication en série; Niveau analytique</DT>
<SO>Journal of cataract and refractive surgery; ISSN 0886-3350; Coden JCSUEV; Etats-Unis; Da. 2004; Vol. 30; No. 5; Pp. 1000-1005; Bibl. 28 ref.</SO>
<LA>Anglais</LA>
<EA>Purpose: To develop a methodology for intraocular lens (IOL) power calculation in which the task of predicting the postoperative position of the IOL Is separated from the calculation itself. Setting: Pharmacia, Groningen, The Netherlands. Methods: The minimum biometry input needed for IOL power calculation is the mean anterior corneal radius and axial length of the eye. The lens haptic plane (LHP) is the plane where the IOL haptics make contact with eye tissue. It is an anatomical site (eg, the equator of the capsular bag) and is independent of the IOL model. The position of the IOL optic in relation to the LHP is determined from the exact design of the IOL. Gullstrand's eye model is adopted to obtain the posterior corneal radius, thickness of the cornea, and refractive indices of the eye media. Thick-lens ray tracing in the paraxial limit is used for the optical calculation. Results: A spreadsheet is given for the calculation. Conclusions: The methodology developed allows for IOL power calculation from first principles (ie, using true physical distances, radii, and refractive indices as input for the optical calculation).</EA>
<CC>002B25B</CC>
<FD>Cristallin; Plan; Lentille épaisse; Tracé rayon; Lentille intraoculaire; Puissance; Chirurgie; Ophtalmologie; Traitement</FD>
<ED>Lens; Plane; Thick lens; Ray tracing; Intraocular lens; Power; Surgery; Ophthalmology; Treatment</ED>
<SD>Cristalino; Plano; Lente grueso; Trazado rayos; Lente intraocular; Potencia; Cirugía; Oftalmología; Tratamiento</SD>
<LO>INIST-20937.354000114546840080</LO>
<ID>04-0296953</ID>
</server>
</inist>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/PascalFrancis/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000F94 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/PascalFrancis/Corpus/biblio.hfd -nk 000F94 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    PascalFrancis
   |étape=   Corpus
   |type=    RBID
   |clé=     Pascal:04-0296953
   |texte=   Using the lens haptic plane concept and thick-lens ray tracing to calculate intraocular lens power
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024