Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

[Peripheral anterior synechiae overlying the haptics of posterior chamber lenses].

Identifieur interne : 004586 ( Ncbi/Merge ); précédent : 004585; suivant : 004587

[Peripheral anterior synechiae overlying the haptics of posterior chamber lenses].

Auteurs : M. Li ; Y. Yin ; J. Chen

Source :

RBID : pubmed:8706576

English descriptors

Abstract

To study the changes of the anterior chamber angle after intraocular lens implantation, 111 patients (130 eyes) with posterior chamber intraocular lens implantation at different post-operative periods were examined by gonioscopy. Peripheral anterior synechia overlying the position of the lens haptic (lens haptic PAS) was observed in up to 50.8% of eyes implanted with haptics vaulted anteriorly by 10%. The lens haptic PAS is easy to be identified, it is a broad based forward displacement of the peripheral iris adhesive to the anterior wall of the anterior chamber angle. The size of the PAS was of half to one o'clock position and occasionally it was of one and a half to two o'clock position. The differences between the rates of occurrence of lens haptic PAS were not significant at different post-operative periods (P > 0.05). 55.9% of the sulcus fixated and 42.3% of the capsular fixated eyes had lens haptic PAS (P > 0.05). There were more lens haptic PAS in eyes with horizontally oriented lens haptics (62.7%) than with lens haptics at vertical position (41.4%, P < 0.05). Regular gonioscopy for posterior chamber lens implantation was recommended.

PubMed: 8706576

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:8706576

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">[Peripheral anterior synechiae overlying the haptics of posterior chamber lenses].</title>
<author>
<name sortKey="Li, M" sort="Li, M" uniqKey="Li M" first="M" last="Li">M. Li</name>
<affiliation>
<nlm:affiliation>Department of Ophthalmology, First Hospital, Beijing Medical University.</nlm:affiliation>
<wicri:noCountry code="subField">Beijing Medical University</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Yin, Y" sort="Yin, Y" uniqKey="Yin Y" first="Y" last="Yin">Y. Yin</name>
</author>
<author>
<name sortKey="Chen, J" sort="Chen, J" uniqKey="Chen J" first="J" last="Chen">J. Chen</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1995">1995</date>
<idno type="RBID">pubmed:8706576</idno>
<idno type="pmid">8706576</idno>
<idno type="wicri:Area/PubMed/Corpus">002096</idno>
<idno type="wicri:Area/PubMed/Curation">002096</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001E26</idno>
<idno type="wicri:Area/Ncbi/Merge">004586</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">[Peripheral anterior synechiae overlying the haptics of posterior chamber lenses].</title>
<author>
<name sortKey="Li, M" sort="Li, M" uniqKey="Li M" first="M" last="Li">M. Li</name>
<affiliation>
<nlm:affiliation>Department of Ophthalmology, First Hospital, Beijing Medical University.</nlm:affiliation>
<wicri:noCountry code="subField">Beijing Medical University</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Yin, Y" sort="Yin, Y" uniqKey="Yin Y" first="Y" last="Yin">Y. Yin</name>
</author>
<author>
<name sortKey="Chen, J" sort="Chen, J" uniqKey="Chen J" first="J" last="Chen">J. Chen</name>
</author>
</analytic>
<series>
<title level="j">[Zhonghua yan ke za zhi] Chinese journal of ophthalmology</title>
<idno type="ISSN">0412-4081</idno>
<imprint>
<date when="1995" type="published">1995</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Female</term>
<term>Gonioscopy</term>
<term>Humans</term>
<term>Iris Diseases (etiology)</term>
<term>Iris Diseases (pathology)</term>
<term>Lenses, Intraocular (adverse effects)</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Tissue Adhesions (etiology)</term>
<term>Tissue Adhesions (pathology)</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en">
<term>Lenses, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Iris Diseases</term>
<term>Tissue Adhesions</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Iris Diseases</term>
<term>Tissue Adhesions</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Female</term>
<term>Gonioscopy</term>
<term>Humans</term>
<term>Male</term>
<term>Middle Aged</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To study the changes of the anterior chamber angle after intraocular lens implantation, 111 patients (130 eyes) with posterior chamber intraocular lens implantation at different post-operative periods were examined by gonioscopy. Peripheral anterior synechia overlying the position of the lens haptic (lens haptic PAS) was observed in up to 50.8% of eyes implanted with haptics vaulted anteriorly by 10%. The lens haptic PAS is easy to be identified, it is a broad based forward displacement of the peripheral iris adhesive to the anterior wall of the anterior chamber angle. The size of the PAS was of half to one o'clock position and occasionally it was of one and a half to two o'clock position. The differences between the rates of occurrence of lens haptic PAS were not significant at different post-operative periods (P > 0.05). 55.9% of the sulcus fixated and 42.3% of the capsular fixated eyes had lens haptic PAS (P > 0.05). There were more lens haptic PAS in eyes with horizontally oriented lens haptics (62.7%) than with lens haptics at vertical position (41.4%, P < 0.05). Regular gonioscopy for posterior chamber lens implantation was recommended.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">8706576</PMID>
<DateCreated>
<Year>1996</Year>
<Month>09</Month>
<Day>06</Day>
</DateCreated>
<DateCompleted>
<Year>1996</Year>
<Month>09</Month>
<Day>06</Day>
</DateCompleted>
<DateRevised>
<Year>2008</Year>
<Month>11</Month>
<Day>21</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0412-4081</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>31</Volume>
<Issue>5</Issue>
<PubDate>
<Year>1995</Year>
<Month>Sep</Month>
</PubDate>
</JournalIssue>
<Title>[Zhonghua yan ke za zhi] Chinese journal of ophthalmology</Title>
<ISOAbbreviation>Zhonghua Yan Ke Za Zhi</ISOAbbreviation>
</Journal>
<ArticleTitle>[Peripheral anterior synechiae overlying the haptics of posterior chamber lenses].</ArticleTitle>
<Pagination>
<MedlinePgn>323-9</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>To study the changes of the anterior chamber angle after intraocular lens implantation, 111 patients (130 eyes) with posterior chamber intraocular lens implantation at different post-operative periods were examined by gonioscopy. Peripheral anterior synechia overlying the position of the lens haptic (lens haptic PAS) was observed in up to 50.8% of eyes implanted with haptics vaulted anteriorly by 10%. The lens haptic PAS is easy to be identified, it is a broad based forward displacement of the peripheral iris adhesive to the anterior wall of the anterior chamber angle. The size of the PAS was of half to one o'clock position and occasionally it was of one and a half to two o'clock position. The differences between the rates of occurrence of lens haptic PAS were not significant at different post-operative periods (P > 0.05). 55.9% of the sulcus fixated and 42.3% of the capsular fixated eyes had lens haptic PAS (P > 0.05). There were more lens haptic PAS in eyes with horizontally oriented lens haptics (62.7%) than with lens haptics at vertical position (41.4%, P < 0.05). Regular gonioscopy for posterior chamber lens implantation was recommended.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Li</LastName>
<ForeName>M</ForeName>
<Initials>M</Initials>
<AffiliationInfo>
<Affiliation>Department of Ophthalmology, First Hospital, Beijing Medical University.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Yin</LastName>
<ForeName>Y</ForeName>
<Initials>Y</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Chen</LastName>
<ForeName>J</ForeName>
<Initials>J</Initials>
</Author>
</AuthorList>
<Language>chi</Language>
<PublicationTypeList>
<PublicationType UI="D004740">English Abstract</PublicationType>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>CHINA</Country>
<MedlineTA>Zhonghua Yan Ke Za Zhi</MedlineTA>
<NlmUniqueID>16210540R</NlmUniqueID>
<ISSNLinking>0412-4081</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000328">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000369">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006068">Gonioscopy</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007499">Iris Diseases</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000209">etiology</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000473">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007910">Lenses, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000009">adverse effects</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000267">Tissue Adhesions</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000209">etiology</QualifierName>
<QualifierName MajorTopicYN="N" UI="Q000473">pathology</QualifierName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1995</Year>
<Month>9</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1995</Year>
<Month>9</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1995</Year>
<Month>9</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">8706576</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Chen, J" sort="Chen, J" uniqKey="Chen J" first="J" last="Chen">J. Chen</name>
<name sortKey="Li, M" sort="Li, M" uniqKey="Li M" first="M" last="Li">M. Li</name>
<name sortKey="Yin, Y" sort="Yin, Y" uniqKey="Yin Y" first="Y" last="Yin">Y. Yin</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004586 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 004586 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Ncbi
   |étape=   Merge
   |type=    RBID
   |clé=     pubmed:8706576
   |texte=   [Peripheral anterior synechiae overlying the haptics of posterior chamber lenses].
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i   -Sk "pubmed:8706576" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024