Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Predictive factor and kappa angle analysis for visual satisfactions in patients with multifocal IOL implantation

Identifieur interne : 001A93 ( Ncbi/Merge ); précédent : 001A92; suivant : 001A94

Predictive factor and kappa angle analysis for visual satisfactions in patients with multifocal IOL implantation

Auteurs : G. Prakash [Inde] ; D R Prakash [Inde] ; A. Agarwal [Inde] ; D A Kumar [Inde] ; A. Agarwal [Inde] ; S. Jacob [Inde]

Source :

RBID : PMC:3178249

Abstract

Purpose

To evaluate the visual acuity and quality-related satisfaction of patients implanted with a refractive design multifocal intraocular lens (IOL), and evaluate the factors predicting it including angle kappa.

Setting

Dr Agarwal's Eye Hospital and Eye Research Centre, Chennai.

Methods

In this prospective trial, 50 eyes of 44 consecutive patients were included. All patients underwent phacoemulsification with multifocal IOL implantation (Rezoom IOL, Abbott Medical Optics). The preoperative and postoperative assessment included slit lamp biomicroscopy, uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA) and kappa angle assessment. At 1 year, 37 patients (43 eyes), who finished follow-up, were asked to rate their symptoms on a graded questionnaire (0–5 for five queries).

Results

The decimal scores for UCVA and BCVA were 0.38±0.21 and 0.47±0.17 (preoperative), and 0.75±0.22 and 0.99±0.11 (postoperative), respectively. Symptom scores were haloes 0.98±1.7, glare 0.69±1.48, blurred distance 1.0±1.7, intermediate 1.34±1.6, near 1.06±1.8. On regression analysis haloes depended on angle kappa and distance UCVA (R2=0.26, P=0.029), and glare on angle kappa (R2=0.26, P=0.033). Poor satisfactions with distance, intermediate, and near vision were linked with distance UCVA (R2=0.17, P=2.3 × 10−4), distance UCVA (R2=0.1, P=0.04), and near UCVA (R2=0.12, P=0.03), respectively. The strongest predictor, however, for overall visual discomfort was distance UCVA (R2=0.1, P=0.04).

Conclusions

Our study suggests that there may be a role of misalignment between the visual and pupillary axis (angle kappa) in the occurrence of photic phenomenon after refractive multifocal IOL implantation.


Url:
DOI: 10.1038/eye.2011.150
PubMed: 21681216
PubMed Central: 3178249

Links toward previous steps (curation, corpus...)


Links to Exploration step

PMC:3178249

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Predictive factor and kappa angle analysis for visual satisfactions in patients with multifocal IOL implantation</title>
<author>
<name sortKey="Prakash, G" sort="Prakash, G" uniqKey="Prakash G" first="G" last="Prakash">G. Prakash</name>
<affiliation wicri:level="1">
<nlm:aff id="aff1">
<institution>Dr Agarwal's Eye Hospital and Eye Research Centre</institution>
, Chennai,
<country>India</country>
</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Prakash, D R" sort="Prakash, D R" uniqKey="Prakash D" first="D R" last="Prakash">D R Prakash</name>
<affiliation wicri:level="1">
<nlm:aff id="aff1">
<institution>Dr Agarwal's Eye Hospital and Eye Research Centre</institution>
, Chennai,
<country>India</country>
</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Agarwal, A" sort="Agarwal, A" uniqKey="Agarwal A" first="A" last="Agarwal">A. Agarwal</name>
<affiliation wicri:level="1">
<nlm:aff id="aff1">
<institution>Dr Agarwal's Eye Hospital and Eye Research Centre</institution>
, Chennai,
<country>India</country>
</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Kumar, D A" sort="Kumar, D A" uniqKey="Kumar D" first="D A" last="Kumar">D A Kumar</name>
<affiliation wicri:level="1">
<nlm:aff id="aff1">
<institution>Dr Agarwal's Eye Hospital and Eye Research Centre</institution>
, Chennai,
<country>India</country>
</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Agarwal, A" sort="Agarwal, A" uniqKey="Agarwal A" first="A" last="Agarwal">A. Agarwal</name>
<affiliation wicri:level="1">
<nlm:aff id="aff1">
<institution>Dr Agarwal's Eye Hospital and Eye Research Centre</institution>
, Chennai,
<country>India</country>
</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Jacob, S" sort="Jacob, S" uniqKey="Jacob S" first="S" last="Jacob">S. Jacob</name>
<affiliation wicri:level="1">
<nlm:aff id="aff1">
<institution>Dr Agarwal's Eye Hospital and Eye Research Centre</institution>
, Chennai,
<country>India</country>
</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">21681216</idno>
<idno type="pmc">3178249</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3178249</idno>
<idno type="RBID">PMC:3178249</idno>
<idno type="doi">10.1038/eye.2011.150</idno>
<date when="2011">2011</date>
<idno type="wicri:Area/Pmc/Corpus">000009</idno>
<idno type="wicri:Area/Pmc/Curation">000009</idno>
<idno type="wicri:Area/Pmc/Checkpoint">001A29</idno>
<idno type="wicri:Area/Ncbi/Merge">001A93</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Predictive factor and kappa angle analysis for visual satisfactions in patients with multifocal IOL implantation</title>
<author>
<name sortKey="Prakash, G" sort="Prakash, G" uniqKey="Prakash G" first="G" last="Prakash">G. Prakash</name>
<affiliation wicri:level="1">
<nlm:aff id="aff1">
<institution>Dr Agarwal's Eye Hospital and Eye Research Centre</institution>
, Chennai,
<country>India</country>
</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Prakash, D R" sort="Prakash, D R" uniqKey="Prakash D" first="D R" last="Prakash">D R Prakash</name>
<affiliation wicri:level="1">
<nlm:aff id="aff1">
<institution>Dr Agarwal's Eye Hospital and Eye Research Centre</institution>
, Chennai,
<country>India</country>
</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Agarwal, A" sort="Agarwal, A" uniqKey="Agarwal A" first="A" last="Agarwal">A. Agarwal</name>
<affiliation wicri:level="1">
<nlm:aff id="aff1">
<institution>Dr Agarwal's Eye Hospital and Eye Research Centre</institution>
, Chennai,
<country>India</country>
</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Kumar, D A" sort="Kumar, D A" uniqKey="Kumar D" first="D A" last="Kumar">D A Kumar</name>
<affiliation wicri:level="1">
<nlm:aff id="aff1">
<institution>Dr Agarwal's Eye Hospital and Eye Research Centre</institution>
, Chennai,
<country>India</country>
</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Agarwal, A" sort="Agarwal, A" uniqKey="Agarwal A" first="A" last="Agarwal">A. Agarwal</name>
<affiliation wicri:level="1">
<nlm:aff id="aff1">
<institution>Dr Agarwal's Eye Hospital and Eye Research Centre</institution>
, Chennai,
<country>India</country>
</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Jacob, S" sort="Jacob, S" uniqKey="Jacob S" first="S" last="Jacob">S. Jacob</name>
<affiliation wicri:level="1">
<nlm:aff id="aff1">
<institution>Dr Agarwal's Eye Hospital and Eye Research Centre</institution>
, Chennai,
<country>India</country>
</nlm:aff>
<country xml:lang="fr">Inde</country>
<wicri:regionArea># see nlm:aff country strict</wicri:regionArea>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Eye</title>
<idno type="ISSN">0950-222X</idno>
<idno type="eISSN">1476-5454</idno>
<imprint>
<date when="2011">2011</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec>
<title>Purpose</title>
<p>To evaluate the visual acuity and quality-related satisfaction of patients implanted with a refractive design multifocal intraocular lens (IOL), and evaluate the factors predicting it including angle kappa.</p>
</sec>
<sec>
<title>Setting</title>
<p>Dr Agarwal's Eye Hospital and Eye Research Centre, Chennai.</p>
</sec>
<sec sec-type="methods">
<title>Methods</title>
<p>In this prospective trial, 50 eyes of 44 consecutive patients were included. All patients underwent phacoemulsification with multifocal IOL implantation (Rezoom IOL, Abbott Medical Optics). The preoperative and postoperative assessment included slit lamp biomicroscopy, uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA) and kappa angle assessment. At 1 year, 37 patients (43 eyes), who finished follow-up, were asked to rate their symptoms on a graded questionnaire (0–5 for five queries).</p>
</sec>
<sec>
<title>Results</title>
<p>The decimal scores for UCVA and BCVA were 0.38±0.21 and 0.47±0.17 (preoperative), and 0.75±0.22 and 0.99±0.11 (postoperative), respectively. Symptom scores were haloes 0.98±1.7, glare 0.69±1.48, blurred distance 1.0±1.7, intermediate 1.34±1.6, near 1.06±1.8. On regression analysis haloes depended on angle kappa and distance UCVA (
<italic>R</italic>
<sup>2</sup>
=0.26,
<italic>P</italic>
=0.029), and glare on angle kappa (
<italic>R</italic>
<sup>2</sup>
=0.26,
<italic>P</italic>
=0.033). Poor satisfactions with distance, intermediate, and near vision were linked with distance UCVA (
<italic>R</italic>
<sup>2</sup>
=0.17,
<italic>P</italic>
=2.3 × 10
<sup>−4</sup>
), distance UCVA (
<italic>R</italic>
<sup>2</sup>
=0.1,
<italic>P</italic>
=0.04), and near UCVA (
<italic>R</italic>
<sup>2</sup>
=0.12,
<italic>P</italic>
=0.03), respectively. The strongest predictor, however, for overall visual discomfort was distance UCVA (
<italic>R</italic>
<sup>2</sup>
=0.1,
<italic>P</italic>
=0.04).</p>
</sec>
<sec>
<title>Conclusions</title>
<p>Our study suggests that there may be a role of misalignment between the visual and pupillary axis (angle kappa) in the occurrence of photic phenomenon after refractive multifocal IOL implantation.</p>
</sec>
</div>
</front>
</TEI>
<pmc article-type="other">
<pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Eye (Lond)</journal-id>
<journal-title-group>
<journal-title>Eye</journal-title>
</journal-title-group>
<issn pub-type="ppub">0950-222X</issn>
<issn pub-type="epub">1476-5454</issn>
<publisher>
<publisher-name>Nature Publishing Group</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">21681216</article-id>
<article-id pub-id-type="pmc">3178249</article-id>
<article-id pub-id-type="pii">eye2011150</article-id>
<article-id pub-id-type="doi">10.1038/eye.2011.150</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Clinical Study</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Predictive factor and kappa angle analysis for visual satisfactions in patients with multifocal IOL implantation</article-title>
<alt-title alt-title-type="running">Analysis in patients with multifocal IOL implantation</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Prakash</surname>
<given-names>G</given-names>
</name>
<xref ref-type="aff" rid="aff1">1</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Prakash</surname>
<given-names>D R</given-names>
</name>
<xref ref-type="aff" rid="aff1">1</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Agarwal</surname>
<given-names>A</given-names>
</name>
<xref ref-type="aff" rid="aff1">1</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Kumar</surname>
<given-names>D A</given-names>
</name>
<xref ref-type="aff" rid="aff1">1</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Agarwal</surname>
<given-names>A</given-names>
</name>
<xref ref-type="aff" rid="aff1">1</xref>
<xref ref-type="corresp" rid="caf1">*</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Jacob</surname>
<given-names>S</given-names>
</name>
<xref ref-type="aff" rid="aff1">1</xref>
</contrib>
<aff id="aff1">
<label>1</label>
<institution>Dr Agarwal's Eye Hospital and Eye Research Centre</institution>
, Chennai,
<country>India</country>
</aff>
</contrib-group>
<author-notes>
<corresp id="caf1">
<label>*</label>
<institution>Dr Agarwal's Eye Hospital and Eye Research Centre</institution>
, 19, Cathedral Road, Chennai 600086, Tamilnadu,
<country>India</country>
. Tel: +91 44 2811 6233; Fax: +91 44 2811 5871. E-mail:
<email>dragarwal@vsnl.com</email>
</corresp>
</author-notes>
<pub-date pub-type="ppub">
<month>09</month>
<year>2011</year>
</pub-date>
<pub-date pub-type="epub">
<day>17</day>
<month>06</month>
<year>2011</year>
</pub-date>
<volume>25</volume>
<issue>9</issue>
<fpage>1187</fpage>
<lpage>1193</lpage>
<history>
<date date-type="received">
<day>08</day>
<month>10</month>
<year>2010</year>
</date>
<date date-type="rev-recd">
<day>01</day>
<month>05</month>
<year>2011</year>
</date>
<date date-type="accepted">
<day>01</day>
<month>05</month>
<year>2011</year>
</date>
</history>
<permissions>
<copyright-statement>Copyright © 2011 Royal College of Ophthalmologists</copyright-statement>
<copyright-year>2011</copyright-year>
<copyright-holder>Royal College of Ophthalmologists</copyright-holder>
</permissions>
<abstract>
<sec>
<title>Purpose</title>
<p>To evaluate the visual acuity and quality-related satisfaction of patients implanted with a refractive design multifocal intraocular lens (IOL), and evaluate the factors predicting it including angle kappa.</p>
</sec>
<sec>
<title>Setting</title>
<p>Dr Agarwal's Eye Hospital and Eye Research Centre, Chennai.</p>
</sec>
<sec sec-type="methods">
<title>Methods</title>
<p>In this prospective trial, 50 eyes of 44 consecutive patients were included. All patients underwent phacoemulsification with multifocal IOL implantation (Rezoom IOL, Abbott Medical Optics). The preoperative and postoperative assessment included slit lamp biomicroscopy, uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA) and kappa angle assessment. At 1 year, 37 patients (43 eyes), who finished follow-up, were asked to rate their symptoms on a graded questionnaire (0–5 for five queries).</p>
</sec>
<sec>
<title>Results</title>
<p>The decimal scores for UCVA and BCVA were 0.38±0.21 and 0.47±0.17 (preoperative), and 0.75±0.22 and 0.99±0.11 (postoperative), respectively. Symptom scores were haloes 0.98±1.7, glare 0.69±1.48, blurred distance 1.0±1.7, intermediate 1.34±1.6, near 1.06±1.8. On regression analysis haloes depended on angle kappa and distance UCVA (
<italic>R</italic>
<sup>2</sup>
=0.26,
<italic>P</italic>
=0.029), and glare on angle kappa (
<italic>R</italic>
<sup>2</sup>
=0.26,
<italic>P</italic>
=0.033). Poor satisfactions with distance, intermediate, and near vision were linked with distance UCVA (
<italic>R</italic>
<sup>2</sup>
=0.17,
<italic>P</italic>
=2.3 × 10
<sup>−4</sup>
), distance UCVA (
<italic>R</italic>
<sup>2</sup>
=0.1,
<italic>P</italic>
=0.04), and near UCVA (
<italic>R</italic>
<sup>2</sup>
=0.12,
<italic>P</italic>
=0.03), respectively. The strongest predictor, however, for overall visual discomfort was distance UCVA (
<italic>R</italic>
<sup>2</sup>
=0.1,
<italic>P</italic>
=0.04).</p>
</sec>
<sec>
<title>Conclusions</title>
<p>Our study suggests that there may be a role of misalignment between the visual and pupillary axis (angle kappa) in the occurrence of photic phenomenon after refractive multifocal IOL implantation.</p>
</sec>
</abstract>
<kwd-group>
<kwd>multifocal intraocular lens</kwd>
<kwd>visual satisfaction</kwd>
<kwd>kappa angle</kwd>
</kwd-group>
</article-meta>
</front>
</pmc>
<affiliations>
<list>
<country>
<li>Inde</li>
</country>
</list>
<tree>
<country name="Inde">
<noRegion>
<name sortKey="Prakash, G" sort="Prakash, G" uniqKey="Prakash G" first="G" last="Prakash">G. Prakash</name>
</noRegion>
<name sortKey="Agarwal, A" sort="Agarwal, A" uniqKey="Agarwal A" first="A" last="Agarwal">A. Agarwal</name>
<name sortKey="Agarwal, A" sort="Agarwal, A" uniqKey="Agarwal A" first="A" last="Agarwal">A. Agarwal</name>
<name sortKey="Jacob, S" sort="Jacob, S" uniqKey="Jacob S" first="S" last="Jacob">S. Jacob</name>
<name sortKey="Kumar, D A" sort="Kumar, D A" uniqKey="Kumar D" first="D A" last="Kumar">D A Kumar</name>
<name sortKey="Prakash, D R" sort="Prakash, D R" uniqKey="Prakash D" first="D R" last="Prakash">D R Prakash</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001A93 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 001A93 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Ncbi
   |étape=   Merge
   |type=    RBID
   |clé=     PMC:3178249
   |texte=   Predictive factor and kappa angle analysis for visual satisfactions in patients with multifocal IOL implantation
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i   -Sk "pubmed:21681216" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024