Postoperative rotation of a 3-piece loop-haptic acrylic intraocular lens.

Identifieur interne : 001274 ( Ncbi/Merge ); précédent : 001273; suivant : 001275

Postoperative rotation of a 3-piece loop-haptic acrylic intraocular lens.

Auteurs : Mario J. Saldanha [Royaume-Uni] ; Larry Benjamin ; Chetan K. Patel

Source :

RBID : pubmed:19781471

English descriptors

Abstract

To assess the rotational stability of the AcrySof MA60BM acrylic intraocular lens (IOL) with and without aspiration of residual lens epithelial cells (LECs).

DOI: 10.1016/j.jcrs.2009.05.024
PubMed: 19781471

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:19781471

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Postoperative rotation of a 3-piece loop-haptic acrylic intraocular lens.</title>
<author>
<name sortKey="Saldanha, Mario J" sort="Saldanha, Mario J" uniqKey="Saldanha M" first="Mario J" last="Saldanha">Mario J. Saldanha</name>
<affiliation wicri:level="1">
<nlm:affiliation>Oxford Eye Hospital, UK.</nlm:affiliation>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Oxford Eye Hospital</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Benjamin, Larry" sort="Benjamin, Larry" uniqKey="Benjamin L" first="Larry" last="Benjamin">Larry Benjamin</name>
</author>
<author>
<name sortKey="Patel, Chetan K" sort="Patel, Chetan K" uniqKey="Patel C" first="Chetan K" last="Patel">Chetan K. Patel</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2009">2009</date>
<idno type="doi">10.1016/j.jcrs.2009.05.024</idno>
<idno type="RBID">pubmed:19781471</idno>
<idno type="pmid">19781471</idno>
<idno type="wicri:Area/PubMed/Corpus">001217</idno>
<idno type="wicri:Area/PubMed/Curation">001217</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001071</idno>
<idno type="wicri:Area/Ncbi/Merge">001274</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Postoperative rotation of a 3-piece loop-haptic acrylic intraocular lens.</title>
<author>
<name sortKey="Saldanha, Mario J" sort="Saldanha, Mario J" uniqKey="Saldanha M" first="Mario J" last="Saldanha">Mario J. Saldanha</name>
<affiliation wicri:level="1">
<nlm:affiliation>Oxford Eye Hospital, UK.</nlm:affiliation>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Oxford Eye Hospital</wicri:regionArea>
</affiliation>
</author>
<author>
<name sortKey="Benjamin, Larry" sort="Benjamin, Larry" uniqKey="Benjamin L" first="Larry" last="Benjamin">Larry Benjamin</name>
</author>
<author>
<name sortKey="Patel, Chetan K" sort="Patel, Chetan K" uniqKey="Patel C" first="Chetan K" last="Patel">Chetan K. Patel</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="eISSN">1873-4502</idno>
<imprint>
<date when="2009" type="published">2009</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Acrylic Resins</term>
<term>Astigmatism (surgery)</term>
<term>Capsulorhexis</term>
<term>Epithelial Cells (pathology)</term>
<term>Female</term>
<term>Foreign-Body Migration (etiology)</term>
<term>Humans</term>
<term>Image Processing, Computer-Assisted</term>
<term>Lens Capsule, Crystalline (surgery)</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Phacoemulsification</term>
<term>Postoperative Complications</term>
<term>Prospective Studies</term>
<term>Rotation</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Acrylic Resins</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Foreign-Body Migration</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Epithelial Cells</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Astigmatism</term>
<term>Lens Capsule, Crystalline</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Capsulorhexis</term>
<term>Female</term>
<term>Humans</term>
<term>Image Processing, Computer-Assisted</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Phacoemulsification</term>
<term>Postoperative Complications</term>
<term>Prospective Studies</term>
<term>Rotation</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To assess the rotational stability of the AcrySof MA60BM acrylic intraocular lens (IOL) with and without aspiration of residual lens epithelial cells (LECs).</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">19781471</PMID>
<DateCreated>
<Year>2009</Year>
<Month>09</Month>
<Day>28</Day>
</DateCreated>
<DateCompleted>
<Year>2009</Year>
<Month>10</Month>
<Day>30</Day>
</DateCompleted>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Electronic">1873-4502</ISSN>
<JournalIssue CitedMedium="Internet">
<Volume>35</Volume>
<Issue>10</Issue>
<PubDate>
<Year>2009</Year>
<Month>Oct</Month>
</PubDate>
</JournalIssue>
<Title>Journal of cataract and refractive surgery</Title>
<ISOAbbreviation>J Cataract Refract Surg</ISOAbbreviation>
</Journal>
<ArticleTitle>Postoperative rotation of a 3-piece loop-haptic acrylic intraocular lens.</ArticleTitle>
<Pagination>
<MedlinePgn>1751-5</MedlinePgn>
</Pagination>
<ELocationID EIdType="doi" ValidYN="Y">10.1016/j.jcrs.2009.05.024</ELocationID>
<Abstract>
<AbstractText Label="PURPOSE" NlmCategory="OBJECTIVE">To assess the rotational stability of the AcrySof MA60BM acrylic intraocular lens (IOL) with and without aspiration of residual lens epithelial cells (LECs).</AbstractText>
<AbstractText Label="SETTING" NlmCategory="METHODS">Stoke Mandeville Hospital, Aylesbury, United Kingdom.</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">Routine phacoemulsification was performed with (Group A) or without (Group B) aspiration of residual LECs (random allocation). The baseline position of the IOL was determined from a video frame acquired at the conclusion of surgery. Postoperative IOL position was documented using digital retroillumination images at 2 weeks and 3 months. Early IOL rotation (surgery to 2 weeks postoperatively) was graded as mild (<10 degrees), moderate (10 to 30 degrees), or severe (>30 degrees) by semiobjective comparison of the images. Late IOL rotation (2 weeks to 3 months) was measured more precisely using purpose-designed software.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">Group A had incomplete aspiration of residual LECs. The only between-group demographic difference was significantly more men in Group A than in Group B (P<.05). There were no cases of severe early IOL rotation. Mild and moderate early rotation occurred in 91.5% of eyes and 8.5% of eyes, respectively. The mean late rotation was 0.03 degrees +/- 3.06 (SD) (range 7.8 to -8.7 degrees). Aspiration of residual LECs made no statistical difference in early or late rotation (P>.05). Between 2 weeks and 3 months, counterclockwise rotation occurred in 50% of all cases.</AbstractText>
<AbstractText Label="CONCLUSIONS" NlmCategory="CONCLUSIONS">Postoperative rotation of the loop-haptic IOL was stable; LEC clearance did not adversely affect performance. The tendency toward counterclockwise rotation would not preclude good performance of a toric model of the IOL.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Saldanha</LastName>
<ForeName>Mario J</ForeName>
<Initials>MJ</Initials>
<AffiliationInfo>
<Affiliation>Oxford Eye Hospital, UK.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Benjamin</LastName>
<ForeName>Larry</ForeName>
<Initials>L</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Patel</LastName>
<ForeName>Chetan K</ForeName>
<Initials>CK</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D016449">Randomized Controlled Trial</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Cataract Refract Surg</MedlineTA>
<NlmUniqueID>8604171</NlmUniqueID>
<ISSNLinking>0886-3350</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D000180">Acrylic Resins</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000180">Acrylic Resins</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D001251">Astigmatism</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019923">Capsulorhexis</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D004847">Epithelial Cells</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000473">pathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005548">Foreign-Body Migration</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000209">etiology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007091">Image Processing, Computer-Assisted</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D007903">Lens Capsule, Crystalline</DescriptorName>
<QualifierName MajorTopicYN="N" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D018918">Phacoemulsification</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D011183">Postoperative Complications</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D011446">Prospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D012399">Rotation</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="received">
<Year>2009</Year>
<Month>3</Month>
<Day>5</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="revised">
<Year>2009</Year>
<Month>5</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="accepted">
<Year>2009</Year>
<Month>5</Month>
<Day>5</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2009</Year>
<Month>9</Month>
<Day>29</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="pubmed">
<Year>2009</Year>
<Month>9</Month>
<Day>29</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2009</Year>
<Month>10</Month>
<Day>31</Day>
<Hour>6</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pii">S0886-3350(09)00601-4</ArticleId>
<ArticleId IdType="doi">10.1016/j.jcrs.2009.05.024</ArticleId>
<ArticleId IdType="pubmed">19781471</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>Royaume-Uni</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Benjamin, Larry" sort="Benjamin, Larry" uniqKey="Benjamin L" first="Larry" last="Benjamin">Larry Benjamin</name>
<name sortKey="Patel, Chetan K" sort="Patel, Chetan K" uniqKey="Patel C" first="Chetan K" last="Patel">Chetan K. Patel</name>
</noCountry>
<country name="Royaume-Uni">
<noRegion>
<name sortKey="Saldanha, Mario J" sort="Saldanha, Mario J" uniqKey="Saldanha M" first="Mario J" last="Saldanha">Mario J. Saldanha</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001274 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 001274 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Ncbi
   |étape=   Merge
   |type=    RBID
   |clé=     pubmed:19781471
   |texte=   Postoperative rotation of a 3-piece loop-haptic acrylic intraocular lens.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i   -Sk "pubmed:19781471" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024