Modified haptic externalizing technique for repositioning dislocated 1-piece acrylic posterior chamber implants.

Identifieur interne : 000C02 ( Ncbi/Merge ); précédent : 000C01; suivant : 000C03

Modified haptic externalizing technique for repositioning dislocated 1-piece acrylic posterior chamber implants.

Auteurs : Clement K. Chan [États-Unis] ; Harold Hawkins ; Steven G. Lin

Source :

RBID : pubmed:17641700

English descriptors

Abstract

To describe a novel vitreoretinal technique and the results of repositioning dislocated 1-piece acrylic posterior chamber intraocular lenses (PCIOL).

DOI: 10.3129/can j ophthalmol.i07-081
PubMed: 17641700

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:17641700

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Modified haptic externalizing technique for repositioning dislocated 1-piece acrylic posterior chamber implants.</title>
<author>
<name sortKey="Chan, Clement K" sort="Chan, Clement K" uniqKey="Chan C" first="Clement K" last="Chan">Clement K. Chan</name>
<affiliation wicri:level="2">
<nlm:affiliation>Southern California Desert Retinal Consultants, Medical Corporation, Palm springs, CA, USA. pschan@aol.com</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Southern California Desert Retinal Consultants, Medical Corporation, Palm springs, CA</wicri:regionArea>
<placeName>
<region type="state">Californie</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Hawkins, Harold" sort="Hawkins, Harold" uniqKey="Hawkins H" first="Harold" last="Hawkins">Harold Hawkins</name>
</author>
<author>
<name sortKey="Lin, Steven G" sort="Lin, Steven G" uniqKey="Lin S" first="Steven G" last="Lin">Steven G. Lin</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2007">2007</date>
<idno type="doi">10.3129/can j ophthalmol.i07-081</idno>
<idno type="RBID">pubmed:17641700</idno>
<idno type="pmid">17641700</idno>
<idno type="wicri:Area/PubMed/Corpus">001606</idno>
<idno type="wicri:Area/PubMed/Curation">001606</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001403</idno>
<idno type="wicri:Area/Ncbi/Merge">000C02</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Modified haptic externalizing technique for repositioning dislocated 1-piece acrylic posterior chamber implants.</title>
<author>
<name sortKey="Chan, Clement K" sort="Chan, Clement K" uniqKey="Chan C" first="Clement K" last="Chan">Clement K. Chan</name>
<affiliation wicri:level="2">
<nlm:affiliation>Southern California Desert Retinal Consultants, Medical Corporation, Palm springs, CA, USA. pschan@aol.com</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Southern California Desert Retinal Consultants, Medical Corporation, Palm springs, CA</wicri:regionArea>
<placeName>
<region type="state">Californie</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Hawkins, Harold" sort="Hawkins, Harold" uniqKey="Hawkins H" first="Harold" last="Hawkins">Harold Hawkins</name>
</author>
<author>
<name sortKey="Lin, Steven G" sort="Lin, Steven G" uniqKey="Lin S" first="Steven G" last="Lin">Steven G. Lin</name>
</author>
</analytic>
<series>
<title level="j">Canadian journal of ophthalmology. Journal canadien d'ophtalmologie</title>
<idno type="ISSN">0008-4182</idno>
<imprint>
<date when="2007" type="published">2007</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Acrylates</term>
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Female</term>
<term>Foreign-Body Migration (surgery)</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular (methods)</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Phacoemulsification</term>
<term>Pilot Projects</term>
<term>Reoperation</term>
<term>Retrospective Studies</term>
<term>Suture Techniques</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Acrylates</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Lens Implantation, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Foreign-Body Migration</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Female</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Phacoemulsification</term>
<term>Pilot Projects</term>
<term>Reoperation</term>
<term>Retrospective Studies</term>
<term>Suture Techniques</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To describe a novel vitreoretinal technique and the results of repositioning dislocated 1-piece acrylic posterior chamber intraocular lenses (PCIOL).</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Owner="NLM" Status="MEDLINE">
<PMID Version="1">17641700</PMID>
<DateCreated>
<Year>2007</Year>
<Month>07</Month>
<Day>20</Day>
</DateCreated>
<DateCompleted>
<Year>2007</Year>
<Month>11</Month>
<Day>13</Day>
</DateCompleted>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0008-4182</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>42</Volume>
<Issue>4</Issue>
<PubDate>
<Year>2007</Year>
<Month>Aug</Month>
</PubDate>
</JournalIssue>
<Title>Canadian journal of ophthalmology. Journal canadien d'ophtalmologie</Title>
<ISOAbbreviation>Can. J. Ophthalmol.</ISOAbbreviation>
</Journal>
<ArticleTitle>Modified haptic externalizing technique for repositioning dislocated 1-piece acrylic posterior chamber implants.</ArticleTitle>
<Pagination>
<MedlinePgn>573-9</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText Label="BACKGROUND" NlmCategory="BACKGROUND">To describe a novel vitreoretinal technique and the results of repositioning dislocated 1-piece acrylic posterior chamber intraocular lenses (PCIOL).</AbstractText>
<AbstractText Label="METHODS" NlmCategory="METHODS">This retrospective study included 7 eyes of 7 patients (ages 41 to 82) who underwent repositioning surgery with vitreoretinal methodology for dislocated 1-piece acrylic PCIOL between 2003 and 2005. Repositioning surgery involved temporary haptic externalization via anterior sclerotomies and passing curved needles of 9-0 or 10-0 polypropylene sutures through soft distal knobs of haptics before reinternalization for sulcus fixation.</AbstractText>
<AbstractText Label="RESULTS" NlmCategory="RESULTS">All 7 repositioned PCIOL remained centered and stable after 12 to 28 months of follow-up (mean = 17.6 months). Mild anterior-posterior intraocular lens (IOL)-tilting developed in 1 eye, but the IOL remained centered and secured in the sulcus with good vision. One PCIOL was exchanged with an anterior chamber intraocular lens (ACIOL) 1 year after repositioning because of recurrent intraocular hemorrhage and cystoid macular edema. Preoperative best corrected Snellen visual acuity (BCVA) ranged from 20/40 to 5/200 (median = 20/70). Postoperative BCVA ranged from 20/20 to 20/200 (median = 20/40). Capsular defect was the cause of IOL dislocation for all cases. Four of 7 eyes (57.1%) had axial myopia.</AbstractText>
<AbstractText Label="INTERPRETATION" NlmCategory="CONCLUSIONS">This repositioning technique for dislocated all-acrylic PCIOL prevents suture slippage and allows secured sulcus fixation. Repositioned haptics should be sutured more than 1 mm from the limbus to avoid iris chafing.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Chan</LastName>
<ForeName>Clement K</ForeName>
<Initials>CK</Initials>
<AffiliationInfo>
<Affiliation>Southern California Desert Retinal Consultants, Medical Corporation, Palm springs, CA, USA. pschan@aol.com</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Hawkins</LastName>
<ForeName>Harold</ForeName>
<Initials>H</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Lin</LastName>
<ForeName>Steven G</ForeName>
<Initials>SG</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>Canada</Country>
<MedlineTA>Can J Ophthalmol</MedlineTA>
<NlmUniqueID>0045312</NlmUniqueID>
<ISSNLinking>0008-4182</ISSNLinking>
</MedlineJournalInfo>
<ChemicalList>
<Chemical>
<RegistryNumber>0</RegistryNumber>
<NameOfSubstance UI="D000179">Acrylates</NameOfSubstance>
</Chemical>
</ChemicalList>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000179">Acrylates</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000328">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000368">Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D000369">Aged, 80 and over</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005260">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D005548">Foreign-Body Migration</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000601">surgery</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D006801">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D019654">Lens Implantation, Intraocular</DescriptorName>
<QualifierName MajorTopicYN="Y" UI="Q000379">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="Y" UI="D007910">Lenses, Intraocular</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008297">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D008875">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D018918">Phacoemulsification</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D010865">Pilot Projects</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012086">Reoperation</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D012189">Retrospective Studies</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D013536">Suture Techniques</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName MajorTopicYN="N" UI="D014792">Visual Acuity</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>2007</Year>
<Month>7</Month>
<Day>21</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>2007</Year>
<Month>11</Month>
<Day>14</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>2007</Year>
<Month>7</Month>
<Day>21</Day>
<Hour>9</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pii">S0008-4182(07)80127-X</ArticleId>
<ArticleId IdType="doi">10.3129/can j ophthalmol.i07-081</ArticleId>
<ArticleId IdType="pubmed">17641700</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>États-Unis</li>
</country>
<region>
<li>Californie</li>
</region>
</list>
<tree>
<noCountry>
<name sortKey="Hawkins, Harold" sort="Hawkins, Harold" uniqKey="Hawkins H" first="Harold" last="Hawkins">Harold Hawkins</name>
<name sortKey="Lin, Steven G" sort="Lin, Steven G" uniqKey="Lin S" first="Steven G" last="Lin">Steven G. Lin</name>
</noCountry>
<country name="États-Unis">
<region name="Californie">
<name sortKey="Chan, Clement K" sort="Chan, Clement K" uniqKey="Chan C" first="Clement K" last="Chan">Clement K. Chan</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000C02 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd -nk 000C02 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Ncbi
   |étape=   Merge
   |type=    RBID
   |clé=     pubmed:17641700
   |texte=   Modified haptic externalizing technique for repositioning dislocated 1-piece acrylic posterior chamber implants.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Merge/RBID.i   -Sk "pubmed:17641700" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024