Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Trans-scleral fixation of dislocated posterior chamber intraocular lenses using a 9/0 microsurgical polypropylene snare.

Identifieur interne : 004535 ( Ncbi/Curation ); précédent : 004534; suivant : 004536

Trans-scleral fixation of dislocated posterior chamber intraocular lenses using a 9/0 microsurgical polypropylene snare.

Auteurs : B C Little [Royaume-Uni] ; P H Rosen ; G. Orr ; G W Aylward

Source :

RBID : pubmed:8119422

English descriptors

Abstract

We describe a new technique for retrieval, sulcus relocation and trans-scleral fixation of posteriorly dislocated (posterior chamber intraocular lenses (PC-IOLs) in a closed eye using a 9/0 polypropylene snare instrument adapted specifically for this purpose. Our experience is described of the first 5 consecutive cases in which the snare was used. The posteriorly dislocated PC-IOL was successfully relocated in 4 of these cases but per-operative fracture of a lens haptic necessitated removal of the IOL in the fifth. A number of surgical techniques have already been described in the management of this problem but we consider the polypropylene snare to offer the advantages of a simpler technique that obviates the need for either manipulation of needles within the eye or complex suturing procedures.

DOI: 10.1038/eye.1993.172
PubMed: 8119422

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:8119422

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Trans-scleral fixation of dislocated posterior chamber intraocular lenses using a 9/0 microsurgical polypropylene snare.</title>
<author>
<name sortKey="Little, B C" sort="Little, B C" uniqKey="Little B" first="B C" last="Little">B C Little</name>
<affiliation wicri:level="3">
<nlm:affiliation>Moorfields Eye Hospital, London, UK.</nlm:affiliation>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Moorfields Eye Hospital, London</wicri:regionArea>
<placeName>
<settlement type="city">Londres</settlement>
<region type="country">Angleterre</region>
<region type="région" nuts="1">Grand Londres</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Rosen, P H" sort="Rosen, P H" uniqKey="Rosen P" first="P H" last="Rosen">P H Rosen</name>
</author>
<author>
<name sortKey="Orr, G" sort="Orr, G" uniqKey="Orr G" first="G" last="Orr">G. Orr</name>
</author>
<author>
<name sortKey="Aylward, G W" sort="Aylward, G W" uniqKey="Aylward G" first="G W" last="Aylward">G W Aylward</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1993">1993</date>
<idno type="RBID">pubmed:8119422</idno>
<idno type="pmid">8119422</idno>
<idno type="doi">10.1038/eye.1993.172</idno>
<idno type="wicri:Area/PubMed/Corpus">002179</idno>
<idno type="wicri:Area/PubMed/Curation">002179</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001E75</idno>
<idno type="wicri:Area/Ncbi/Merge">004535</idno>
<idno type="wicri:Area/Ncbi/Curation">004535</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Trans-scleral fixation of dislocated posterior chamber intraocular lenses using a 9/0 microsurgical polypropylene snare.</title>
<author>
<name sortKey="Little, B C" sort="Little, B C" uniqKey="Little B" first="B C" last="Little">B C Little</name>
<affiliation wicri:level="3">
<nlm:affiliation>Moorfields Eye Hospital, London, UK.</nlm:affiliation>
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Moorfields Eye Hospital, London</wicri:regionArea>
<placeName>
<settlement type="city">Londres</settlement>
<region type="country">Angleterre</region>
<region type="région" nuts="1">Grand Londres</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Rosen, P H" sort="Rosen, P H" uniqKey="Rosen P" first="P H" last="Rosen">P H Rosen</name>
</author>
<author>
<name sortKey="Orr, G" sort="Orr, G" uniqKey="Orr G" first="G" last="Orr">G. Orr</name>
</author>
<author>
<name sortKey="Aylward, G W" sort="Aylward, G W" uniqKey="Aylward G" first="G W" last="Aylward">G W Aylward</name>
</author>
</analytic>
<series>
<title level="j">Eye (London, England)</title>
<idno type="ISSN">0950-222X</idno>
<imprint>
<date when="1993" type="published">1993</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Female</term>
<term>Humans</term>
<term>Intraoperative Complications (surgery)</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Ophthalmology (instrumentation)</term>
<term>Ophthalmology (methods)</term>
<term>Reoperation</term>
<term>Surgical Instruments</term>
<term>Suture Techniques</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Ophthalmology</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Ophthalmology</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Intraoperative Complications</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Aged</term>
<term>Female</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Reoperation</term>
<term>Surgical Instruments</term>
<term>Suture Techniques</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">We describe a new technique for retrieval, sulcus relocation and trans-scleral fixation of posteriorly dislocated (posterior chamber intraocular lenses (PC-IOLs) in a closed eye using a 9/0 polypropylene snare instrument adapted specifically for this purpose. Our experience is described of the first 5 consecutive cases in which the snare was used. The posteriorly dislocated PC-IOL was successfully relocated in 4 of these cases but per-operative fracture of a lens haptic necessitated removal of the IOL in the fifth. A number of surgical techniques have already been described in the management of this problem but we consider the polypropylene snare to offer the advantages of a simpler technique that obviates the need for either manipulation of needles within the eye or complex suturing procedures.</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004535 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Curation/biblio.hfd -nk 004535 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Ncbi
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:8119422
   |texte=   Trans-scleral fixation of dislocated posterior chamber intraocular lenses using a 9/0 microsurgical polypropylene snare.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Curation/RBID.i   -Sk "pubmed:8119422" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024