[Experience with a flexible anterior chamber lens].
Identifieur interne : 002566 ( Ncbi/Curation ); précédent : 002565; suivant : 002567[Experience with a flexible anterior chamber lens].
Auteurs : D T Pham [Allemagne] ; J. Wollensak ; V. HommerichSource :
- Klinische Monatsblätter für Augenheilkunde [ 0023-2165 ] ; 1990.
English descriptors
- KwdEn :
- MESH :
- adverse effects : Lenses, Intraocular.
- epidemiology : Postoperative Complications.
- Anterior Chamber, Follow-Up Studies, Humans, Methods, Prosthesis Design, Retrospective Studies.
Abstract
Clinical findings in 37 eyes in which flexible anterior chamber lenses (Symflex) had been implanted were retrospectively analyzed. Visual rehabilitation was achieved in 24 out of 26 secondary implantations following ICCE. In the first postoperative week pupillary block developed in 2 eyes and toxic lens syndrome in one. One retinal detachment occurred in the late postoperative course. Specific complications associated with the anterior chamber lens were goniosynechiae in 2 eyes and distortion of the pupil, also in 2 cases. Gonioscopic examination showed that the haptic was in the desired position, in the chamber angle, in 35 eyes. In two cases the haptic was located at the iris periphery.
DOI: 10.1055/s-2008-1046152
PubMed: 2348634
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: Pour aller vers cette notice dans l'étape Curation :002237
- to stream PubMed, to step Curation: Pour aller vers cette notice dans l'étape Curation :002237
- to stream PubMed, to step Checkpoint: Pour aller vers cette notice dans l'étape Curation :001F50
- to stream Ncbi, to step Merge: Pour aller vers cette notice dans l'étape Curation :002566
Links to Exploration step
pubmed:2348634Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">[Experience with a flexible anterior chamber lens].</title>
<author><name sortKey="Pham, D T" sort="Pham, D T" uniqKey="Pham D" first="D T" last="Pham">D T Pham</name>
<affiliation wicri:level="3"><nlm:affiliation>Augenklinik, Klinikum Rudolf Virchow, Charlottenburg, Freie Universität, Berlin.</nlm:affiliation>
<country>Allemagne</country>
<placeName><settlement type="city">Berlin</settlement>
<region type="land" nuts="2">Berlin</region>
</placeName>
<wicri:orgArea>Augenklinik, Klinikum Rudolf Virchow, Charlottenburg, Freie Universität</wicri:orgArea>
</affiliation>
</author>
<author><name sortKey="Wollensak, J" sort="Wollensak, J" uniqKey="Wollensak J" first="J" last="Wollensak">J. Wollensak</name>
</author>
<author><name sortKey="Hommerich, V" sort="Hommerich, V" uniqKey="Hommerich V" first="V" last="Hommerich">V. Hommerich</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="1990">1990</date>
<idno type="RBID">pubmed:2348634</idno>
<idno type="pmid">2348634</idno>
<idno type="doi">10.1055/s-2008-1046152</idno>
<idno type="wicri:Area/PubMed/Corpus">002237</idno>
<idno type="wicri:Area/PubMed/Curation">002237</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001F50</idno>
<idno type="wicri:Area/Ncbi/Merge">002566</idno>
<idno type="wicri:Area/Ncbi/Curation">002566</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">[Experience with a flexible anterior chamber lens].</title>
<author><name sortKey="Pham, D T" sort="Pham, D T" uniqKey="Pham D" first="D T" last="Pham">D T Pham</name>
<affiliation wicri:level="3"><nlm:affiliation>Augenklinik, Klinikum Rudolf Virchow, Charlottenburg, Freie Universität, Berlin.</nlm:affiliation>
<country>Allemagne</country>
<placeName><settlement type="city">Berlin</settlement>
<region type="land" nuts="2">Berlin</region>
</placeName>
<wicri:orgArea>Augenklinik, Klinikum Rudolf Virchow, Charlottenburg, Freie Universität</wicri:orgArea>
</affiliation>
</author>
<author><name sortKey="Wollensak, J" sort="Wollensak, J" uniqKey="Wollensak J" first="J" last="Wollensak">J. Wollensak</name>
</author>
<author><name sortKey="Hommerich, V" sort="Hommerich, V" uniqKey="Hommerich V" first="V" last="Hommerich">V. Hommerich</name>
</author>
</analytic>
<series><title level="j">Klinische Monatsblätter für Augenheilkunde</title>
<idno type="ISSN">0023-2165</idno>
<imprint><date when="1990" type="published">1990</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Anterior Chamber</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Lenses, Intraocular (adverse effects)</term>
<term>Methods</term>
<term>Postoperative Complications (epidemiology)</term>
<term>Prosthesis Design</term>
<term>Retrospective Studies</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en"><term>Lenses, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="epidemiology" xml:lang="en"><term>Postoperative Complications</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Anterior Chamber</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Methods</term>
<term>Prosthesis Design</term>
<term>Retrospective Studies</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Clinical findings in 37 eyes in which flexible anterior chamber lenses (Symflex) had been implanted were retrospectively analyzed. Visual rehabilitation was achieved in 24 out of 26 secondary implantations following ICCE. In the first postoperative week pupillary block developed in 2 eyes and toxic lens syndrome in one. One retinal detachment occurred in the late postoperative course. Specific complications associated with the anterior chamber lens were goniosynechiae in 2 eyes and distortion of the pupil, also in 2 cases. Gonioscopic examination showed that the haptic was in the desired position, in the chamber angle, in 35 eyes. In two cases the haptic was located at the iris periphery.</div>
</front>
</TEI>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002566 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Curation/biblio.hfd -nk 002566 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Ncbi |étape= Curation |type= RBID |clé= pubmed:2348634 |texte= [Experience with a flexible anterior chamber lens]. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Curation/RBID.i -Sk "pubmed:2348634" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Curation/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |