Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Modified Siepser sliding knot technique for scleral fixation of subluxated posterior chamber intraocular lens.

Identifieur interne : 001422 ( Ncbi/Curation ); précédent : 001421; suivant : 001423

Modified Siepser sliding knot technique for scleral fixation of subluxated posterior chamber intraocular lens.

Auteurs : Kyoung Tak Ma [Corée du Sud] ; Sung Yong Kang ; Joo Youn Shin ; Na Rae Kim ; Gong Je Seong ; Chan Yun Kim

Source :

RBID : pubmed:20117698

English descriptors

Abstract

We describe a new technique of scleral fixation for the management of dislocated intraocular lenses (IOL). A suture is tied inside the eye around the dislocated haptic to prevent slippage of the IOL after surgery. The technique, which is safe and less invasive than previous methods, was used in 3 patients and the results are presented.

DOI: 10.1016/j.jcrs.2009.07.048
PubMed: 20117698

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:20117698

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Modified Siepser sliding knot technique for scleral fixation of subluxated posterior chamber intraocular lens.</title>
<author>
<name sortKey="Ma, Kyoung Tak" sort="Ma, Kyoung Tak" uniqKey="Ma K" first="Kyoung Tak" last="Ma">Kyoung Tak Ma</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Ophthalmology, Yonsei University College of Medicine, Siloam Eye Hospital, Seoul, Korea.</nlm:affiliation>
<country xml:lang="fr">Corée du Sud</country>
<wicri:regionArea>Department of Ophthalmology, Yonsei University College of Medicine, Siloam Eye Hospital, Seoul</wicri:regionArea>
<placeName>
<settlement type="city">Séoul</settlement>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Kang, Sung Yong" sort="Kang, Sung Yong" uniqKey="Kang S" first="Sung Yong" last="Kang">Sung Yong Kang</name>
</author>
<author>
<name sortKey="Shin, Joo Youn" sort="Shin, Joo Youn" uniqKey="Shin J" first="Joo Youn" last="Shin">Joo Youn Shin</name>
</author>
<author>
<name sortKey="Kim, Na Rae" sort="Kim, Na Rae" uniqKey="Kim N" first="Na Rae" last="Kim">Na Rae Kim</name>
</author>
<author>
<name sortKey="Seong, Gong Je" sort="Seong, Gong Je" uniqKey="Seong G" first="Gong Je" last="Seong">Gong Je Seong</name>
</author>
<author>
<name sortKey="Kim, Chan Yun" sort="Kim, Chan Yun" uniqKey="Kim C" first="Chan Yun" last="Kim">Chan Yun Kim</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2010">2010</date>
<idno type="doi">10.1016/j.jcrs.2009.07.048</idno>
<idno type="RBID">pubmed:20117698</idno>
<idno type="pmid">20117698</idno>
<idno type="wicri:Area/PubMed/Corpus">001145</idno>
<idno type="wicri:Area/PubMed/Curation">001145</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000F19</idno>
<idno type="wicri:Area/Ncbi/Merge">001422</idno>
<idno type="wicri:Area/Ncbi/Curation">001422</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Modified Siepser sliding knot technique for scleral fixation of subluxated posterior chamber intraocular lens.</title>
<author>
<name sortKey="Ma, Kyoung Tak" sort="Ma, Kyoung Tak" uniqKey="Ma K" first="Kyoung Tak" last="Ma">Kyoung Tak Ma</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Ophthalmology, Yonsei University College of Medicine, Siloam Eye Hospital, Seoul, Korea.</nlm:affiliation>
<country xml:lang="fr">Corée du Sud</country>
<wicri:regionArea>Department of Ophthalmology, Yonsei University College of Medicine, Siloam Eye Hospital, Seoul</wicri:regionArea>
<placeName>
<settlement type="city">Séoul</settlement>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Kang, Sung Yong" sort="Kang, Sung Yong" uniqKey="Kang S" first="Sung Yong" last="Kang">Sung Yong Kang</name>
</author>
<author>
<name sortKey="Shin, Joo Youn" sort="Shin, Joo Youn" uniqKey="Shin J" first="Joo Youn" last="Shin">Joo Youn Shin</name>
</author>
<author>
<name sortKey="Kim, Na Rae" sort="Kim, Na Rae" uniqKey="Kim N" first="Na Rae" last="Kim">Na Rae Kim</name>
</author>
<author>
<name sortKey="Seong, Gong Je" sort="Seong, Gong Je" uniqKey="Seong G" first="Gong Je" last="Seong">Gong Je Seong</name>
</author>
<author>
<name sortKey="Kim, Chan Yun" sort="Kim, Chan Yun" uniqKey="Kim C" first="Chan Yun" last="Kim">Chan Yun Kim</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="eISSN">1873-4502</idno>
<imprint>
<date when="2010" type="published">2010</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Child</term>
<term>Humans</term>
<term>Intraocular Pressure</term>
<term>Lens Implantation, Intraocular (methods)</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Prosthesis Failure</term>
<term>Refraction, Ocular (physiology)</term>
<term>Sclera (surgery)</term>
<term>Suture Techniques</term>
<term>Visual Acuity (physiology)</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Lens Implantation, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="physiology" xml:lang="en">
<term>Refraction, Ocular</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Sclera</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Child</term>
<term>Humans</term>
<term>Intraocular Pressure</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Prosthesis Failure</term>
<term>Suture Techniques</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">We describe a new technique of scleral fixation for the management of dislocated intraocular lenses (IOL). A suture is tied inside the eye around the dislocated haptic to prevent slippage of the IOL after surgery. The technique, which is safe and less invasive than previous methods, was used in 3 patients and the results are presented.</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001422 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Curation/biblio.hfd -nk 001422 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Ncbi
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:20117698
   |texte=   Modified Siepser sliding knot technique for scleral fixation of subluxated posterior chamber intraocular lens.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Curation/RBID.i   -Sk "pubmed:20117698" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024