Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Gonioscopic findings following insertion of Pearce Lasagap and Nova Curve Kratz posterior chamber intraocular lenses in extrapsular cataract extraction.

Identifieur interne : 004288 ( Ncbi/Checkpoint ); précédent : 004287; suivant : 004289

Gonioscopic findings following insertion of Pearce Lasagap and Nova Curve Kratz posterior chamber intraocular lenses in extrapsular cataract extraction.

Auteurs : G. Naylor [Royaume-Uni] ; G A Sutton

Source :

RBID : pubmed:2812691

English descriptors

Abstract

The gonioscopic appearances of 45 eyes that had undergone extracapsular cataract extraction with insertion of a Pearce Lasagap posterior chamber intraocular lens (group A) were compared with those of 45 eyes that had undergone the same procedure except for insertion of a Nova Curve Kratz posterior chamber lens (group B). Prominence of one or both loops was seen in 35 eyes (78%) of group A, with peripheral anterior synechiae (PAS) in 25 (55%). Prominence of one loop was seen in 14 eyes (31%) of group B, with PAS in 8 (18%) (P less than 0.001). Final visual acuity was comparable in both groups, 98% achieving 6/12 (20/40) or better. Although not statistically significant, the incidence of pigment dispersion, uveitis, discomfort and visual aberrations was greater in group A than in group B. We suggest that the apparent superiority of the Nova Curve Kratz lens in terms of the smaller incidence of loop prominence, as well as the reduced incidence of these other complications, is due to the fact that its haptic is inserted into the optic's edge rather than into the anterior surface of the lens optic, as is the case with the Lasagap lens.

PubMed: 2812691


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:2812691

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Gonioscopic findings following insertion of Pearce Lasagap and Nova Curve Kratz posterior chamber intraocular lenses in extrapsular cataract extraction.</title>
<author>
<name sortKey="Naylor, G" sort="Naylor, G" uniqKey="Naylor G" first="G" last="Naylor">G. Naylor</name>
<affiliation wicri:level="2">
<nlm:affiliation>Birmingham and Midland Eye Hospital, England.</nlm:affiliation>
<country>Royaume-Uni</country>
<placeName>
<region type="country">Angleterre</region>
</placeName>
<wicri:cityArea>Birmingham and Midland Eye Hospital</wicri:cityArea>
</affiliation>
</author>
<author>
<name sortKey="Sutton, G A" sort="Sutton, G A" uniqKey="Sutton G" first="G A" last="Sutton">G A Sutton</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1989">1989</date>
<idno type="RBID">pubmed:2812691</idno>
<idno type="pmid">2812691</idno>
<idno type="wicri:Area/PubMed/Corpus">002258</idno>
<idno type="wicri:Area/PubMed/Curation">002258</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001F92</idno>
<idno type="wicri:Area/Ncbi/Merge">004288</idno>
<idno type="wicri:Area/Ncbi/Curation">004288</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">004288</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Gonioscopic findings following insertion of Pearce Lasagap and Nova Curve Kratz posterior chamber intraocular lenses in extrapsular cataract extraction.</title>
<author>
<name sortKey="Naylor, G" sort="Naylor, G" uniqKey="Naylor G" first="G" last="Naylor">G. Naylor</name>
<affiliation wicri:level="2">
<nlm:affiliation>Birmingham and Midland Eye Hospital, England.</nlm:affiliation>
<country>Royaume-Uni</country>
<placeName>
<region type="country">Angleterre</region>
</placeName>
<wicri:cityArea>Birmingham and Midland Eye Hospital</wicri:cityArea>
</affiliation>
</author>
<author>
<name sortKey="Sutton, G A" sort="Sutton, G A" uniqKey="Sutton G" first="G A" last="Sutton">G A Sutton</name>
</author>
</analytic>
<series>
<title level="j">Ophthalmic surgery</title>
<idno type="ISSN">0022-023X</idno>
<imprint>
<date when="1989" type="published">1989</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aged</term>
<term>Cataract Extraction (methods)</term>
<term>Corneal Diseases (etiology)</term>
<term>Corneal Diseases (pathology)</term>
<term>Endothelium, Corneal (pathology)</term>
<term>Gonioscopy</term>
<term>Humans</term>
<term>Intraocular Pressure</term>
<term>Lenses, Intraocular (adverse effects)</term>
<term>Uveitis (etiology)</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en">
<term>Lenses, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Corneal Diseases</term>
<term>Uveitis</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Cataract Extraction</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Corneal Diseases</term>
<term>Endothelium, Corneal</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Gonioscopy</term>
<term>Humans</term>
<term>Intraocular Pressure</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The gonioscopic appearances of 45 eyes that had undergone extracapsular cataract extraction with insertion of a Pearce Lasagap posterior chamber intraocular lens (group A) were compared with those of 45 eyes that had undergone the same procedure except for insertion of a Nova Curve Kratz posterior chamber lens (group B). Prominence of one or both loops was seen in 35 eyes (78%) of group A, with peripheral anterior synechiae (PAS) in 25 (55%). Prominence of one loop was seen in 14 eyes (31%) of group B, with PAS in 8 (18%) (P less than 0.001). Final visual acuity was comparable in both groups, 98% achieving 6/12 (20/40) or better. Although not statistically significant, the incidence of pigment dispersion, uveitis, discomfort and visual aberrations was greater in group A than in group B. We suggest that the apparent superiority of the Nova Curve Kratz lens in terms of the smaller incidence of loop prominence, as well as the reduced incidence of these other complications, is due to the fact that its haptic is inserted into the optic's edge rather than into the anterior surface of the lens optic, as is the case with the Lasagap lens.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Royaume-Uni</li>
</country>
<region>
<li>Angleterre</li>
</region>
</list>
<tree>
<noCountry>
<name sortKey="Sutton, G A" sort="Sutton, G A" uniqKey="Sutton G" first="G A" last="Sutton">G A Sutton</name>
</noCountry>
<country name="Royaume-Uni">
<region name="Angleterre">
<name sortKey="Naylor, G" sort="Naylor, G" uniqKey="Naylor G" first="G" last="Naylor">G. Naylor</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Ncbi/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 004288 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Ncbi/Checkpoint/biblio.hfd -nk 004288 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Ncbi
   |étape=   Checkpoint
   |type=    RBID
   |clé=     pubmed:2812691
   |texte=   Gonioscopic findings following insertion of Pearce Lasagap and Nova Curve Kratz posterior chamber intraocular lenses in extrapsular cataract extraction.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Ncbi/Checkpoint/RBID.i   -Sk "pubmed:2812691" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Ncbi/Checkpoint/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024