[Neuhann capsulorhexis: a technic for reliable implantation of the capsule sack].
Identifieur interne : 00A395 ( Main/Merge ); précédent : 00A394; suivant : 00A396[Neuhann capsulorhexis: a technic for reliable implantation of the capsule sack].
Auteurs : E. Haefliger ; T. NeuhannSource :
- Klinische Monatsblätter für Augenheilkunde [ 0023-2165 ] ; 1988.
English descriptors
- KwdEn :
- MESH :
- chemical : Methylmethacrylates.
- etiology : Postoperative Complications.
- surgery : Lens Capsule, Crystalline, Lens, Crystalline.
- Humans, Lenses, Intraocular, Prosthesis Design.
Abstract
The Neuhann Capsulorhexis allows for a continuous, circular opening in the anterior lens capsule. After excavation of the lens matter the circular round edge in the anterior capsule provides maximum stability in the zonulolenticular diaphragm and facilitates controlled in-the-bag implantation of the lens haptic. Histologic studies of cadaver eyes have revealed that the correlation between the position of the lens loops as intended by the surgeon intraoperatively and their actual positioning is poor. It has therefore not been possible to prove the advantages of all-in-the-bag implantation as compared to sulcus fixation. The Neuhann Capsulorhexis reduces the morphological variability of the anterior capsule; furthermore, the position of the lens haptic can easily be determined both intraoperatively as well as postoperatively. This is a prerequisite for evaluating the best position for the lens haptic as well as for clinical evaluation of new types of intraocular lens.
DOI: 10.1055/s-2008-1050144
PubMed: 3404954
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: 002284
- to stream PubMed, to step Curation: 002284
- to stream PubMed, to step Checkpoint: 002002
- to stream Ncbi, to step Merge: 004313
- to stream Ncbi, to step Curation: 004313
- to stream Ncbi, to step Checkpoint: 004313
Links to Exploration step
pubmed:3404954Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">[Neuhann capsulorhexis: a technic for reliable implantation of the capsule sack].</title>
<author><name sortKey="Haefliger, E" sort="Haefliger, E" uniqKey="Haefliger E" first="E" last="Haefliger">E. Haefliger</name>
<affiliation><nlm:affiliation>Augenabteilung des Kantonsspitals, Liestal.</nlm:affiliation>
<wicri:noCountry code="subField">Liestal</wicri:noCountry>
</affiliation>
</author>
<author><name sortKey="Neuhann, T" sort="Neuhann, T" uniqKey="Neuhann T" first="T" last="Neuhann">T. Neuhann</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="1988">1988</date>
<idno type="RBID">pubmed:3404954</idno>
<idno type="pmid">3404954</idno>
<idno type="doi">10.1055/s-2008-1050144</idno>
<idno type="wicri:Area/PubMed/Corpus">002284</idno>
<idno type="wicri:Area/PubMed/Curation">002284</idno>
<idno type="wicri:Area/PubMed/Checkpoint">002002</idno>
<idno type="wicri:Area/Ncbi/Merge">004313</idno>
<idno type="wicri:Area/Ncbi/Curation">004313</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">004313</idno>
<idno type="wicri:doubleKey">0023-2165:1988:Haefliger E:neuhann:capsulorhexis:a</idno>
<idno type="wicri:Area/Main/Merge">00A395</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">[Neuhann capsulorhexis: a technic for reliable implantation of the capsule sack].</title>
<author><name sortKey="Haefliger, E" sort="Haefliger, E" uniqKey="Haefliger E" first="E" last="Haefliger">E. Haefliger</name>
<affiliation><nlm:affiliation>Augenabteilung des Kantonsspitals, Liestal.</nlm:affiliation>
<wicri:noCountry code="subField">Liestal</wicri:noCountry>
</affiliation>
</author>
<author><name sortKey="Neuhann, T" sort="Neuhann, T" uniqKey="Neuhann T" first="T" last="Neuhann">T. Neuhann</name>
</author>
</analytic>
<series><title level="j">Klinische Monatsblätter für Augenheilkunde</title>
<idno type="ISSN">0023-2165</idno>
<imprint><date when="1988" type="published">1988</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Humans</term>
<term>Lens Capsule, Crystalline (surgery)</term>
<term>Lens, Crystalline (surgery)</term>
<term>Lenses, Intraocular</term>
<term>Methylmethacrylates</term>
<term>Postoperative Complications (etiology)</term>
<term>Prosthesis Design</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Methylmethacrylates</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en"><term>Postoperative Complications</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en"><term>Lens Capsule, Crystalline</term>
<term>Lens, Crystalline</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Prosthesis Design</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">The Neuhann Capsulorhexis allows for a continuous, circular opening in the anterior lens capsule. After excavation of the lens matter the circular round edge in the anterior capsule provides maximum stability in the zonulolenticular diaphragm and facilitates controlled in-the-bag implantation of the lens haptic. Histologic studies of cadaver eyes have revealed that the correlation between the position of the lens loops as intended by the surgeon intraoperatively and their actual positioning is poor. It has therefore not been possible to prove the advantages of all-in-the-bag implantation as compared to sulcus fixation. The Neuhann Capsulorhexis reduces the morphological variability of the anterior capsule; furthermore, the position of the lens haptic can easily be determined both intraoperatively as well as postoperatively. This is a prerequisite for evaluating the best position for the lens haptic as well as for clinical evaluation of new types of intraocular lens.</div>
</front>
</TEI>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 00A395 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 00A395 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Merge |type= RBID |clé= pubmed:3404954 |texte= [Neuhann capsulorhexis: a technic for reliable implantation of the capsule sack]. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Merge/RBID.i -Sk "pubmed:3404954" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Merge/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |