Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Phacoemulsification in the presence of pseudoexfoliation: Challenges and options

Identifieur interne : 009317 ( Main/Merge ); précédent : 009316; suivant : 009318

Phacoemulsification in the presence of pseudoexfoliation: Challenges and options

Auteurs : I. Howard Fine ; Richard S. Hoffman

Source :

RBID : ISTEX:0301307DEF385CA0857BD673E51005460BC61066

Abstract

Phacoemulsification in the presence of pseudoexfoliation of the lens presents surgeons with particular challenges. The frequency of intraoperative and postoperative complications such as zonular dialysis, capsular tears, vitreous loss, and intraocular lens (IOL) decentration may be reduced with careful attention to detail and careful surgical technique. Improvements in phacoemulsification technology, IOLs, and new capsular supporting rings allow surgeons to perform safer surgery in these eyes. We present the challenges of and options for managing cataract extraction in the presence of pseudoexfoliation.

Url:
DOI: 10.1016/S0886-3350(97)80336-7

Links toward previous steps (curation, corpus...)


Links to Exploration step

ISTEX:0301307DEF385CA0857BD673E51005460BC61066

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Phacoemulsification in the presence of pseudoexfoliation: Challenges and options</title>
<author>
<name sortKey="Fine, I Howard" sort="Fine, I Howard" uniqKey="Fine I" first="I. Howard" last="Fine">I. Howard Fine</name>
</author>
<author>
<name sortKey="Hoffman, Richard S" sort="Hoffman, Richard S" uniqKey="Hoffman R" first="Richard S." last="Hoffman">Richard S. Hoffman</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:0301307DEF385CA0857BD673E51005460BC61066</idno>
<date when="1997" year="1997">1997</date>
<idno type="doi">10.1016/S0886-3350(97)80336-7</idno>
<idno type="url">https://api.istex.fr/document/0301307DEF385CA0857BD673E51005460BC61066/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">002396</idno>
<idno type="wicri:Area/Istex/Curation">002396</idno>
<idno type="wicri:Area/Istex/Checkpoint">003B66</idno>
<idno type="wicri:doubleKey">0886-3350:1997:Fine I:phacoemulsification:in:the</idno>
<idno type="wicri:Area/Main/Merge">009317</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Phacoemulsification in the presence of pseudoexfoliation: Challenges and options</title>
<author>
<name sortKey="Fine, I Howard" sort="Fine, I Howard" uniqKey="Fine I" first="I. Howard" last="Fine">I. Howard Fine</name>
<affiliation>
<wicri:noCountry code="subField">EugeneOregon Eye AssociatesEugene</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Hoffman, Richard S" sort="Hoffman, Richard S" uniqKey="Hoffman R" first="Richard S." last="Hoffman">Richard S. Hoffman</name>
<affiliation>
<wicri:noCountry code="subField">EugeneOregon Eye AssociatesEugene</wicri:noCountry>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Journal of Cataract & Refractive Surgery</title>
<title level="j" type="abbrev">JCRS</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<publisher>ELSEVIER</publisher>
<date type="published" when="1997">1997</date>
<biblScope unit="volume">23</biblScope>
<biblScope unit="issue">2</biblScope>
<biblScope unit="page" from="160">160</biblScope>
<biblScope unit="page" to="165">165</biblScope>
</imprint>
<idno type="ISSN">0886-3350</idno>
</series>
<idno type="istex">0301307DEF385CA0857BD673E51005460BC61066</idno>
<idno type="DOI">10.1016/S0886-3350(97)80336-7</idno>
<idno type="PII">S0886-3350(97)80336-7</idno>
<idno type="ArticleID">80336</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0886-3350</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Phacoemulsification in the presence of pseudoexfoliation of the lens presents surgeons with particular challenges. The frequency of intraoperative and postoperative complications such as zonular dialysis, capsular tears, vitreous loss, and intraocular lens (IOL) decentration may be reduced with careful attention to detail and careful surgical technique. Improvements in phacoemulsification technology, IOLs, and new capsular supporting rings allow surgeons to perform safer surgery in these eyes. We present the challenges of and options for managing cataract extraction in the presence of pseudoexfoliation.</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 009317 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 009317 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Merge
   |type=    RBID
   |clé=     ISTEX:0301307DEF385CA0857BD673E51005460BC61066
   |texte=   Phacoemulsification in the presence of pseudoexfoliation: Challenges and options
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024