Sutured piggyback toric intraocular lenses to correct high astigmatism

Identifieur interne : 007453 ( Main/Merge ); précédent : 007452; suivant : 007454

Sutured piggyback toric intraocular lenses to correct high astigmatism

Auteurs : James P. Gills [États-Unis]

Source :

RBID : Pascal:03-0216711

Descripteurs français

English descriptors

Abstract

A 74-year-old woman presented for bilateral cataract surgery, which was performed 3 days apart. Corneal astigmatism was 4.25 diopters (D) in the right eye and 4.87 D in the left. After cataract extraction through 6.0 mm scleral incisions, 2 toric, plate-haptic, silicone intraocular lenses (lOLs), each with a 3.50 D cylinder add power (2.30 D at spectacle plane), were sutured together and implanted in the bag. Both eyes had limbal relaxing incisions postoperatively. Four months postoperatively, corneal astigmatism was 4.50 D in the right eye and 4.00 D in the left. Refractive astigmatism was 0.50 D with an uncorrected visual acuity of 20/40 in both eyes. No IOL rotation was observed. Suturing toric lenses together allows greater correction of astigmatism without concern about counter rotation of the lenses.

Links toward previous steps (curation, corpus...)


Links to Exploration step

Pascal:03-0216711

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en" level="a">Sutured piggyback toric intraocular lenses to correct high astigmatism</title>
<author>
<name sortKey="Gills, James P" sort="Gills, James P" uniqKey="Gills J" first="James P." last="Gills">James P. Gills</name>
<affiliation wicri:level="2">
<inist:fA14 i1="01">
<s1>St. Luke's Cataract and Laser Institute</s1>
<s2>Tarpon Springs, Florida</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName>
<region type="state">Floride</region>
</placeName>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">INIST</idno>
<idno type="inist">03-0216711</idno>
<date when="2003">2003</date>
<idno type="stanalyst">PASCAL 03-0216711 INIST</idno>
<idno type="RBID">Pascal:03-0216711</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">001179</idno>
<idno type="wicri:Area/PascalFrancis/Curation">000332</idno>
<idno type="wicri:Area/PascalFrancis/Checkpoint">000E21</idno>
<idno type="wicri:doubleKey">0886-3350:2003:Gills J:sutured:piggyback:toric</idno>
<idno type="wicri:Area/Main/Merge">007453</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a">Sutured piggyback toric intraocular lenses to correct high astigmatism</title>
<author>
<name sortKey="Gills, James P" sort="Gills, James P" uniqKey="Gills J" first="James P." last="Gills">James P. Gills</name>
<affiliation wicri:level="2">
<inist:fA14 i1="01">
<s1>St. Luke's Cataract and Laser Institute</s1>
<s2>Tarpon Springs, Florida</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName>
<region type="state">Floride</region>
</placeName>
</affiliation>
</author>
</analytic>
<series>
<title level="j" type="main">Journal of cataract and refractive surgery</title>
<title level="j" type="abbreviated">J. cataract refractive surg.</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="2003">2003</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<title level="j" type="main">Journal of cataract and refractive surgery</title>
<title level="j" type="abbreviated">J. cataract refractive surg.</title>
<idno type="ISSN">0886-3350</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Astigmatism</term>
<term>Case study</term>
<term>Cataract</term>
<term>Elderly</term>
<term>High</term>
<term>Intraocular lens</term>
<term>Posterior chamber</term>
<term>Surgery</term>
<term>Toric lens</term>
<term>Treatment</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Astigmatisme</term>
<term>Haut</term>
<term>Traitement</term>
<term>Lentille intraoculaire</term>
<term>Lentille torique</term>
<term>Chambre postérieure</term>
<term>Etude cas</term>
<term>Personne âgée</term>
<term>Cataracte</term>
<term>Chirurgie</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr">
<term>Personne âgée</term>
<term>Chirurgie</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">A 74-year-old woman presented for bilateral cataract surgery, which was performed 3 days apart. Corneal astigmatism was 4.25 diopters (D) in the right eye and 4.87 D in the left. After cataract extraction through 6.0 mm scleral incisions, 2 toric, plate-haptic, silicone intraocular lenses (lOLs), each with a 3.50 D cylinder add power (2.30 D at spectacle plane), were sutured together and implanted in the bag. Both eyes had limbal relaxing incisions postoperatively. Four months postoperatively, corneal astigmatism was 4.50 D in the right eye and 4.00 D in the left. Refractive astigmatism was 0.50 D with an uncorrected visual acuity of 20/40 in both eyes. No IOL rotation was observed. Suturing toric lenses together allows greater correction of astigmatism without concern about counter rotation of the lenses.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>États-Unis</li>
</country>
<region>
<li>Floride</li>
</region>
</list>
<tree>
<country name="États-Unis">
<region name="Floride">
<name sortKey="Gills, James P" sort="Gills, James P" uniqKey="Gills J" first="James P." last="Gills">James P. Gills</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 007453 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 007453 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Merge
   |type=    RBID
   |clé=     Pascal:03-0216711
   |texte=   Sutured piggyback toric intraocular lenses to correct high astigmatism
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024