Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Transscleral suture technique for fixation of a dislocated posterior chamber intraocular lens.

Identifieur interne : 006A13 ( Main/Merge ); précédent : 006A12; suivant : 006A14

Transscleral suture technique for fixation of a dislocated posterior chamber intraocular lens.

Auteurs : Quan-Hong Han [République populaire de Chine] ; Lin Wang ; Yan-Nian Hui

Source :

RBID : pubmed:15210213

English descriptors

Abstract

We describe a double-loop-knot technique for repositioning a displaced posterior chamber intraocular lens (IOL) that facilitates placement of scleral fixation sutures around the haptic for IOL stabilization. The technique minimizes the intraocular manipulations necessary to create a suture loop around the haptic of a dislocated IOL as well as scleral incisions required for IOL exchange.

DOI: 10.1016/j.jcrs.2003.11.043
PubMed: 15210213

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:15210213

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Transscleral suture technique for fixation of a dislocated posterior chamber intraocular lens.</title>
<author>
<name sortKey="Han, Quan Hong" sort="Han, Quan Hong" uniqKey="Han Q" first="Quan-Hong" last="Han">Quan-Hong Han</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Ophthalmology, Xijing Hospital, The Fourth Military Medical University, ChangLe-Xi Road 17, 710032 Xi'an, Shaanxi, China.</nlm:affiliation>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Department of Ophthalmology, Xijing Hospital, The Fourth Military Medical University, ChangLe-Xi Road 17, 710032 Xi'an, Shaanxi</wicri:regionArea>
<wicri:noRegion>Shaanxi</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Wang, Lin" sort="Wang, Lin" uniqKey="Wang L" first="Lin" last="Wang">Lin Wang</name>
</author>
<author>
<name sortKey="Hui, Yan Nian" sort="Hui, Yan Nian" uniqKey="Hui Y" first="Yan-Nian" last="Hui">Yan-Nian Hui</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2004">2004</date>
<idno type="RBID">pubmed:15210213</idno>
<idno type="pmid">15210213</idno>
<idno type="doi">10.1016/j.jcrs.2003.11.043</idno>
<idno type="wicri:Area/PubMed/Corpus">001B19</idno>
<idno type="wicri:Area/PubMed/Curation">001B19</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001773</idno>
<idno type="wicri:Area/Ncbi/Merge">000542</idno>
<idno type="wicri:Area/Ncbi/Curation">000542</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000542</idno>
<idno type="wicri:doubleKey">0886-3350:2004:Han Q:transscleral:suture:technique</idno>
<idno type="wicri:Area/Main/Merge">006A13</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Transscleral suture technique for fixation of a dislocated posterior chamber intraocular lens.</title>
<author>
<name sortKey="Han, Quan Hong" sort="Han, Quan Hong" uniqKey="Han Q" first="Quan-Hong" last="Han">Quan-Hong Han</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Ophthalmology, Xijing Hospital, The Fourth Military Medical University, ChangLe-Xi Road 17, 710032 Xi'an, Shaanxi, China.</nlm:affiliation>
<country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Department of Ophthalmology, Xijing Hospital, The Fourth Military Medical University, ChangLe-Xi Road 17, 710032 Xi'an, Shaanxi</wicri:regionArea>
<wicri:noRegion>Shaanxi</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Wang, Lin" sort="Wang, Lin" uniqKey="Wang L" first="Lin" last="Wang">Lin Wang</name>
</author>
<author>
<name sortKey="Hui, Yan Nian" sort="Hui, Yan Nian" uniqKey="Hui Y" first="Yan-Nian" last="Hui">Yan-Nian Hui</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="2004" type="published">2004</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Foreign-Body Migration (surgery)</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Polypropylenes</term>
<term>Reoperation</term>
<term>Sclera (surgery)</term>
<term>Suture Techniques</term>
<term>Sutures</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en">
<term>Polypropylenes</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Foreign-Body Migration</term>
<term>Sclera</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Reoperation</term>
<term>Suture Techniques</term>
<term>Sutures</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">We describe a double-loop-knot technique for repositioning a displaced posterior chamber intraocular lens (IOL) that facilitates placement of scleral fixation sutures around the haptic for IOL stabilization. The technique minimizes the intraocular manipulations necessary to create a suture loop around the haptic of a dislocated IOL as well as scleral incisions required for IOL exchange.</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 006A13 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 006A13 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Merge
   |type=    RBID
   |clé=     pubmed:15210213
   |texte=   Transscleral suture technique for fixation of a dislocated posterior chamber intraocular lens.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Merge/RBID.i   -Sk "pubmed:15210213" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024