Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

fMRI-Compatible Electromagnetic Haptic Interface.

Identifieur interne : 006453 ( Main/Merge ); précédent : 006452; suivant : 006454

fMRI-Compatible Electromagnetic Haptic Interface.

Auteurs : R. Riener [Suisse] ; T. Villgrattner ; R. Kleiser ; T. Nef ; S. Kollias

Source :

RBID : pubmed:17281892

Abstract

A new haptic interface device is suggested, which can be used for functional magnetic resonance imaging (fMRI) studies. The basic component of this 1 DOF haptic device are two coils that produce a Lorentz force induced by the large static magnetic field of the MR scanner. A MR-compatible optical angular encoder and a optical force sensor enable the implementation of different control architectures for haptic interactions. The challenge was to provide a large torque, and not to affect image quality by the currents applied in the device. The haptic device was tested in a 3T MR scanner. With a current of up to 1A and a distance of 1m to the focal point of the MR-scanner it was possible to generate torques of up to 4 Nm. Within these boundaries image quality was not affected.

DOI: 10.1109/IEMBS.2005.1616123
PubMed: 17281892

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:17281892

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">fMRI-Compatible Electromagnetic Haptic Interface.</title>
<author>
<name sortKey="Riener, R" sort="Riener, R" uniqKey="Riener R" first="R" last="Riener">R. Riener</name>
<affiliation wicri:level="1">
<nlm:affiliation>IEEE Member, Rehabilitation Engineering Group, ETH and University Zurich, Switzerland. riener@control.ee.ethz.ch.</nlm:affiliation>
<country xml:lang="fr">Suisse</country>
<wicri:regionArea>IEEE Member, Rehabilitation Engineering Group, ETH and University Zurich</wicri:regionArea>
<wicri:noRegion>ETH and University Zurich</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Villgrattner, T" sort="Villgrattner, T" uniqKey="Villgrattner T" first="T" last="Villgrattner">T. Villgrattner</name>
</author>
<author>
<name sortKey="Kleiser, R" sort="Kleiser, R" uniqKey="Kleiser R" first="R" last="Kleiser">R. Kleiser</name>
</author>
<author>
<name sortKey="Nef, T" sort="Nef, T" uniqKey="Nef T" first="T" last="Nef">T. Nef</name>
</author>
<author>
<name sortKey="Kollias, S" sort="Kollias, S" uniqKey="Kollias S" first="S" last="Kollias">S. Kollias</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2005">2005</date>
<idno type="RBID">pubmed:17281892</idno>
<idno type="pmid">17281892</idno>
<idno type="doi">10.1109/IEMBS.2005.1616123</idno>
<idno type="wicri:Area/PubMed/Corpus">001690</idno>
<idno type="wicri:Area/PubMed/Curation">001690</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001639</idno>
<idno type="wicri:Area/Ncbi/Merge">000A78</idno>
<idno type="wicri:Area/Ncbi/Curation">000A78</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000A78</idno>
<idno type="wicri:doubleKey">1557-170X:2005:Riener R:fmri:compatible:electromagnetic</idno>
<idno type="wicri:Area/Main/Merge">006453</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">fMRI-Compatible Electromagnetic Haptic Interface.</title>
<author>
<name sortKey="Riener, R" sort="Riener, R" uniqKey="Riener R" first="R" last="Riener">R. Riener</name>
<affiliation wicri:level="1">
<nlm:affiliation>IEEE Member, Rehabilitation Engineering Group, ETH and University Zurich, Switzerland. riener@control.ee.ethz.ch.</nlm:affiliation>
<country xml:lang="fr">Suisse</country>
<wicri:regionArea>IEEE Member, Rehabilitation Engineering Group, ETH and University Zurich</wicri:regionArea>
<wicri:noRegion>ETH and University Zurich</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Villgrattner, T" sort="Villgrattner, T" uniqKey="Villgrattner T" first="T" last="Villgrattner">T. Villgrattner</name>
</author>
<author>
<name sortKey="Kleiser, R" sort="Kleiser, R" uniqKey="Kleiser R" first="R" last="Kleiser">R. Kleiser</name>
</author>
<author>
<name sortKey="Nef, T" sort="Nef, T" uniqKey="Nef T" first="T" last="Nef">T. Nef</name>
</author>
<author>
<name sortKey="Kollias, S" sort="Kollias, S" uniqKey="Kollias S" first="S" last="Kollias">S. Kollias</name>
</author>
</analytic>
<series>
<title level="j">Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference</title>
<idno type="ISSN">1557-170X</idno>
<imprint>
<date when="2005" type="published">2005</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">A new haptic interface device is suggested, which can be used for functional magnetic resonance imaging (fMRI) studies. The basic component of this 1 DOF haptic device are two coils that produce a Lorentz force induced by the large static magnetic field of the MR scanner. A MR-compatible optical angular encoder and a optical force sensor enable the implementation of different control architectures for haptic interactions. The challenge was to provide a large torque, and not to affect image quality by the currents applied in the device. The haptic device was tested in a 3T MR scanner. With a current of up to 1A and a distance of 1m to the focal point of the MR-scanner it was possible to generate torques of up to 4 Nm. Within these boundaries image quality was not affected.</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 006453 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 006453 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Merge
   |type=    RBID
   |clé=     pubmed:17281892
   |texte=   fMRI-Compatible Electromagnetic Haptic Interface.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Merge/RBID.i   -Sk "pubmed:17281892" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Merge/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024