Diminished suture strength after robotic needle driver manipulation.
Identifieur interne : 003818 ( Main/Merge ); précédent : 003817; suivant : 003819Diminished suture strength after robotic needle driver manipulation.
Auteurs : Daniel Ricchiuti [États-Unis] ; Jeffrey Cerone ; Scott Shie ; Ajay Jetley ; Donald Noe ; Mark KovacikSource :
- Journal of endourology / Endourological Society [ 1557-900X ] ; 2010.
English descriptors
- KwdEn :
- MESH :
Abstract
Robot-assisted minimally invasive surgery has become a routine surgical option for the treatment of prostate cancer. Despite its technical advancements, the da Vinci(®) Surgical System still lacks haptic feedback to the surgeon, resulting in a maximally applied compressive force by the robotic needle driver during every grasping maneuver. Without this perceptional sense of touch and grip control, repetitive robotic needle driver manipulation may unknowingly lead to irreparable damage to fine sutures used during delicate anastomotic repairs. For robotic prostatectomy, any such loss of integrity can potentially lead to premature breakdown of the urethrovesical anastomosis and urine extravasation, especially important for a less-than-perfectly fashioned anastomotic repair. Although it has already been established that overhandling of sutures using handheld laparoscopic instruments can lead to reduced suture strength, it has not been established to what extent this may occur after robotic surgical procedures. We present analytical data and analyses concerning the failure strength of fine sutures commonly used for urethrovesical anastomotic repair during robotic prostatectomy, after repetitive robotic needle driver manipulation. When compared with noncompromised monofilament suture controls, the average maximal failure force after repetitive robotic manipulation was significantly reduced by 35% (p < 0.0001). Similarly, the average maximal failure force of braided sutures was significantly reduced after repetitive robotic manipulation by 3% (p = 0.009). This work demonstrates that significant reductions in monofilament and braided suture strength integrity can occur after customary repetitive manipulation by robotic needle drivers in an ex vivo model, with further research warranted in the in vivo setting.
DOI: 10.1089/end.2009.0573
PubMed: 20653422
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: 001058
- to stream PubMed, to step Curation: 001058
- to stream PubMed, to step Checkpoint: 000F68
- to stream Ncbi, to step Merge: 001625
- to stream Ncbi, to step Curation: 001625
- to stream Ncbi, to step Checkpoint: 001625
Links to Exploration step
pubmed:20653422Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Diminished suture strength after robotic needle driver manipulation.</title>
<author><name sortKey="Ricchiuti, Daniel" sort="Ricchiuti, Daniel" uniqKey="Ricchiuti D" first="Daniel" last="Ricchiuti">Daniel Ricchiuti</name>
<affiliation wicri:level="2"><nlm:affiliation>Department of Urology, St. Elizabeth's Health Center, Youngstown, Ohio, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Urology, St. Elizabeth's Health Center, Youngstown, Ohio</wicri:regionArea>
<placeName><region type="state">Ohio</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Cerone, Jeffrey" sort="Cerone, Jeffrey" uniqKey="Cerone J" first="Jeffrey" last="Cerone">Jeffrey Cerone</name>
</author>
<author><name sortKey="Shie, Scott" sort="Shie, Scott" uniqKey="Shie S" first="Scott" last="Shie">Scott Shie</name>
</author>
<author><name sortKey="Jetley, Ajay" sort="Jetley, Ajay" uniqKey="Jetley A" first="Ajay" last="Jetley">Ajay Jetley</name>
</author>
<author><name sortKey="Noe, Donald" sort="Noe, Donald" uniqKey="Noe D" first="Donald" last="Noe">Donald Noe</name>
</author>
<author><name sortKey="Kovacik, Mark" sort="Kovacik, Mark" uniqKey="Kovacik M" first="Mark" last="Kovacik">Mark Kovacik</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2010">2010</date>
<idno type="doi">10.1089/end.2009.0573</idno>
<idno type="RBID">pubmed:20653422</idno>
<idno type="pmid">20653422</idno>
<idno type="wicri:Area/PubMed/Corpus">001058</idno>
<idno type="wicri:Area/PubMed/Curation">001058</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000F68</idno>
<idno type="wicri:Area/Ncbi/Merge">001625</idno>
<idno type="wicri:Area/Ncbi/Curation">001625</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">001625</idno>
<idno type="wicri:Area/Main/Merge">003818</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Diminished suture strength after robotic needle driver manipulation.</title>
<author><name sortKey="Ricchiuti, Daniel" sort="Ricchiuti, Daniel" uniqKey="Ricchiuti D" first="Daniel" last="Ricchiuti">Daniel Ricchiuti</name>
<affiliation wicri:level="2"><nlm:affiliation>Department of Urology, St. Elizabeth's Health Center, Youngstown, Ohio, USA.</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Urology, St. Elizabeth's Health Center, Youngstown, Ohio</wicri:regionArea>
<placeName><region type="state">Ohio</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Cerone, Jeffrey" sort="Cerone, Jeffrey" uniqKey="Cerone J" first="Jeffrey" last="Cerone">Jeffrey Cerone</name>
</author>
<author><name sortKey="Shie, Scott" sort="Shie, Scott" uniqKey="Shie S" first="Scott" last="Shie">Scott Shie</name>
</author>
<author><name sortKey="Jetley, Ajay" sort="Jetley, Ajay" uniqKey="Jetley A" first="Ajay" last="Jetley">Ajay Jetley</name>
</author>
<author><name sortKey="Noe, Donald" sort="Noe, Donald" uniqKey="Noe D" first="Donald" last="Noe">Donald Noe</name>
</author>
<author><name sortKey="Kovacik, Mark" sort="Kovacik, Mark" uniqKey="Kovacik M" first="Mark" last="Kovacik">Mark Kovacik</name>
</author>
</analytic>
<series><title level="j">Journal of endourology / Endourological Society</title>
<idno type="eISSN">1557-900X</idno>
<imprint><date when="2010" type="published">2010</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Humans</term>
<term>Needles</term>
<term>Robotics (instrumentation)</term>
<term>Sutures</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en"><term>Robotics</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Humans</term>
<term>Needles</term>
<term>Sutures</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Robot-assisted minimally invasive surgery has become a routine surgical option for the treatment of prostate cancer. Despite its technical advancements, the da Vinci(®) Surgical System still lacks haptic feedback to the surgeon, resulting in a maximally applied compressive force by the robotic needle driver during every grasping maneuver. Without this perceptional sense of touch and grip control, repetitive robotic needle driver manipulation may unknowingly lead to irreparable damage to fine sutures used during delicate anastomotic repairs. For robotic prostatectomy, any such loss of integrity can potentially lead to premature breakdown of the urethrovesical anastomosis and urine extravasation, especially important for a less-than-perfectly fashioned anastomotic repair. Although it has already been established that overhandling of sutures using handheld laparoscopic instruments can lead to reduced suture strength, it has not been established to what extent this may occur after robotic surgical procedures. We present analytical data and analyses concerning the failure strength of fine sutures commonly used for urethrovesical anastomotic repair during robotic prostatectomy, after repetitive robotic needle driver manipulation. When compared with noncompromised monofilament suture controls, the average maximal failure force after repetitive robotic manipulation was significantly reduced by 35% (p < 0.0001). Similarly, the average maximal failure force of braided sutures was significantly reduced after repetitive robotic manipulation by 3% (p = 0.009). This work demonstrates that significant reductions in monofilament and braided suture strength integrity can occur after customary repetitive manipulation by robotic needle drivers in an ex vivo model, with further research warranted in the in vivo setting.</div>
</front>
</TEI>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Merge
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003818 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Merge/biblio.hfd -nk 003818 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Merge |type= RBID |clé= pubmed:20653422 |texte= Diminished suture strength after robotic needle driver manipulation. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Merge/RBID.i -Sk "pubmed:20653422" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Merge/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
This area was generated with Dilib version V0.6.23. |