A contact lens photostimulator for surgical monitoring

Identifieur interne : 009A56 ( Main/Exploration ); précédent : 009A55; suivant : 009A57

A contact lens photostimulator for surgical monitoring

Auteurs : G. F. A. Harding [Royaume-Uni] ; Vernon H. Smith [Royaume-Uni] ; H. C. Yorke [Royaume-Uni]

Source :

RBID : ISTEX:F5560282DA1F7EC3B5E4DBB8B0D8D3B48935B950

English descriptors

Abstract

A haptic contact lens stimulator has been developed to allow monitoring of the visual evoked potential to flash stimulation during orbital surgery. The contact lens stimulator is fitted with a small plastic prism into which a fibre-optic cable is inserted at right angles to the axis of the contact lens. This allows both the stimulator and the fibre-optic to be permanently in place throughout orbital surgery without interfering with the surgeon's vision or dexterity. Using this technique continuous evoked potentials can be obtained allowing immediate feedback to the surgeon of any condition threatening the integrity of the optic nerve. The technique has now been used on over 20 eyes and is commercially available.

Url:
DOI: 10.1016/0013-4694(87)90082-4


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title>A contact lens photostimulator for surgical monitoring</title>
<author>
<name sortKey="Harding, G F A" sort="Harding, G F A" uniqKey="Harding G" first="G. F. A." last="Harding">G. F. A. Harding</name>
</author>
<author>
<name sortKey="Smith, Vernon H" sort="Smith, Vernon H" uniqKey="Smith V" first="Vernon H." last="Smith">Vernon H. Smith</name>
</author>
<author>
<name sortKey="Yorke, H C" sort="Yorke, H C" uniqKey="Yorke H" first="H. C." last="Yorke">H. C. Yorke</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:F5560282DA1F7EC3B5E4DBB8B0D8D3B48935B950</idno>
<date when="1987" year="1987">1987</date>
<idno type="doi">10.1016/0013-4694(87)90082-4</idno>
<idno type="url">https://api.istex.fr/document/F5560282DA1F7EC3B5E4DBB8B0D8D3B48935B950/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000179</idno>
<idno type="wicri:Area/Istex/Curation">000179</idno>
<idno type="wicri:Area/Istex/Checkpoint">004884</idno>
<idno type="wicri:doubleKey">0013-4694:1987:Harding G:a:contact:lens</idno>
<idno type="wicri:Area/Main/Merge">00A526</idno>
<idno type="wicri:source">PubMed</idno>
<idno type="RBID">pubmed:2434317</idno>
<idno type="wicri:Area/PubMed/Corpus">002316</idno>
<idno type="wicri:Area/PubMed/Curation">002316</idno>
<idno type="wicri:Area/PubMed/Checkpoint">002039</idno>
<idno type="wicri:Area/Ncbi/Merge">002B56</idno>
<idno type="wicri:Area/Ncbi/Curation">002B56</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">002B56</idno>
<idno type="wicri:doubleKey">0013-4694:1987:Harding G:a:contact:lens</idno>
<idno type="wicri:Area/Main/Merge">00A497</idno>
<idno type="wicri:Area/Main/Curation">009A56</idno>
<idno type="wicri:Area/Main/Exploration">009A56</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a">A contact lens photostimulator for surgical monitoring</title>
<author>
<name sortKey="Harding, G F A" sort="Harding, G F A" uniqKey="Harding G" first="G. F. A." last="Harding">G. F. A. Harding</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Department of Vision Sciences, Aston University, Birmingham B4 7ET</wicri:regionArea>
<wicri:noRegion>Birmingham B4 7ET</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Smith, Vernon H" sort="Smith, Vernon H" uniqKey="Smith V" first="Vernon H." last="Smith">Vernon H. Smith</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Department of Vision Sciences, Aston University, Birmingham B4 7ET</wicri:regionArea>
<wicri:noRegion>Birmingham B4 7ET</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Yorke, H C" sort="Yorke, H C" uniqKey="Yorke H" first="H. C." last="Yorke">H. C. Yorke</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Royaume-Uni</country>
<wicri:regionArea>Department of Vision Sciences, Aston University, Birmingham B4 7ET</wicri:regionArea>
<wicri:noRegion>Birmingham B4 7ET</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Electroencephalography and Clinical Neurophysiology</title>
<title level="j" type="abbrev">EEG</title>
<idno type="ISSN">0013-4694</idno>
<imprint>
<publisher>ELSEVIER</publisher>
<date type="published" when="1986">1986</date>
<biblScope unit="volume">66</biblScope>
<biblScope unit="issue">3</biblScope>
<biblScope unit="page" from="322">322</biblScope>
<biblScope unit="page" to="326">326</biblScope>
</imprint>
<idno type="ISSN">0013-4694</idno>
</series>
<idno type="istex">F5560282DA1F7EC3B5E4DBB8B0D8D3B48935B950</idno>
<idno type="DOI">10.1016/0013-4694(87)90082-4</idno>
<idno type="PII">0013-4694(87)90082-4</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0013-4694</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Contact Lenses</term>
<term>Evoked Potentials, Visual</term>
<term>Humans</term>
<term>Intraoperative Complications (diagnosis)</term>
<term>Monitoring, Physiologic</term>
<term>Ophthalmologic Surgical Procedures</term>
<term>Optic Nerve</term>
<term>Photic Stimulation (instrumentation)</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnosis" xml:lang="en">
<term>Intraoperative Complications</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Photic Stimulation</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Contact Lenses</term>
<term>Evoked Potentials, Visual</term>
<term>Humans</term>
<term>Monitoring, Physiologic</term>
<term>Ophthalmologic Surgical Procedures</term>
<term>Optic Nerve</term>
</keywords>
</textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">A haptic contact lens stimulator has been developed to allow monitoring of the visual evoked potential to flash stimulation during orbital surgery. The contact lens stimulator is fitted with a small plastic prism into which a fibre-optic cable is inserted at right angles to the axis of the contact lens. This allows both the stimulator and the fibre-optic to be permanently in place throughout orbital surgery without interfering with the surgeon's vision or dexterity. Using this technique continuous evoked potentials can be obtained allowing immediate feedback to the surgeon of any condition threatening the integrity of the optic nerve. The technique has now been used on over 20 eyes and is commercially available.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Royaume-Uni</li>
</country>
</list>
<tree>
<country name="Royaume-Uni">
<noRegion>
<name sortKey="Harding, G F A" sort="Harding, G F A" uniqKey="Harding G" first="G. F. A." last="Harding">G. F. A. Harding</name>
</noRegion>
<name sortKey="Smith, Vernon H" sort="Smith, Vernon H" uniqKey="Smith V" first="Vernon H." last="Smith">Vernon H. Smith</name>
<name sortKey="Yorke, H C" sort="Yorke, H C" uniqKey="Yorke H" first="H. C." last="Yorke">H. C. Yorke</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 009A56 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 009A56 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:F5560282DA1F7EC3B5E4DBB8B0D8D3B48935B950
   |texte=   A contact lens photostimulator for surgical monitoring
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024