Scleral fixation of a silicone plate haptic intraocular lens in a patient showing repeated pupillary intraocular lens capture.
Identifieur interne : 00A526 ( Main/Exploration ); précédent : 00A525; suivant : 00A527Scleral fixation of a silicone plate haptic intraocular lens in a patient showing repeated pupillary intraocular lens capture.
Auteurs : Kyoung Tak Ma [Corée du Sud] ; Sung Soo Kim ; Gong Jae Seong ; Hyung Keun Lee ; Chan Yun KimSource :
- Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye [ 1542-8877 ]
English descriptors
- KwdEn :
- MESH :
- chemical : Silicone Elastomers.
- complications : Marfan Syndrome.
- etiology : Pupil Disorders.
- methods : Lens Implantation, Intraocular.
- surgery : Sclera.
- Adult, Humans, Lenses, Intraocular, Male, Recurrence, Suture Techniques, Visual Acuity.
Abstract
A 39-year-old man with Marfan syndrome underwent scleral fixation using a three-piece foldable intraocular lens and experienced repeated pupillary intraocular lens captures secondary to a pliable iris. As a result, the patient needed an additional pupilloplasty. In the opposite eye, a silicone plate haptic intraocular lens was used for scleral fixation because it was thought that the plate design could prevent pupillary intraocular lens capture, even in cases involving a pliable iris. At the 27-month follow-up examination, the patient showed good centration of the intraocular lens in the eye that used the silicone plate haptic intraocular lens without pupillary intraocular lens capture.
PubMed: 18717443
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: 001409
- to stream PubMed, to step Curation: 001409
- to stream PubMed, to step Checkpoint: 002278
- to stream Ncbi, to step Merge: 000F00
- to stream Ncbi, to step Curation: 000F00
- to stream Ncbi, to step Checkpoint: 000F00
- to stream Main, to step Merge: 00B071
- to stream Main, to step Curation: 00A526
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Scleral fixation of a silicone plate haptic intraocular lens in a patient showing repeated pupillary intraocular lens capture.</title>
<author><name sortKey="Ma, Kyoung Tak" sort="Ma, Kyoung Tak" uniqKey="Ma K" first="Kyoung Tak" last="Ma">Kyoung Tak Ma</name>
<affiliation wicri:level="3"><nlm:affiliation>Siloam Eye Hospital, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea.</nlm:affiliation>
<country xml:lang="fr">Corée du Sud</country>
<wicri:regionArea>Siloam Eye Hospital, Department of Ophthalmology, Yonsei University College of Medicine, Seoul</wicri:regionArea>
<placeName><settlement type="city">Séoul</settlement>
</placeName>
</affiliation>
</author>
<author><name sortKey="Kim, Sung Soo" sort="Kim, Sung Soo" uniqKey="Kim S" first="Sung Soo" last="Kim">Sung Soo Kim</name>
</author>
<author><name sortKey="Seong, Gong Jae" sort="Seong, Gong Jae" uniqKey="Seong G" first="Gong Jae" last="Seong">Gong Jae Seong</name>
</author>
<author><name sortKey="Lee, Hyung Keun" sort="Lee, Hyung Keun" uniqKey="Lee H" first="Hyung Keun" last="Lee">Hyung Keun Lee</name>
</author>
<author><name sortKey="Kim, Chan Yun" sort="Kim, Chan Yun" uniqKey="Kim C" first="Chan Yun" last="Kim">Chan Yun Kim</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="????"><PubDate><MedlineDate>2008 Jul-Aug</MedlineDate>
</PubDate>
</date>
<idno type="RBID">pubmed:18717443</idno>
<idno type="pmid">18717443</idno>
<idno type="wicri:Area/PubMed/Corpus">001409</idno>
<idno type="wicri:Area/PubMed/Curation">001409</idno>
<idno type="wicri:Area/PubMed/Checkpoint">002278</idno>
<idno type="wicri:Area/Ncbi/Merge">000F00</idno>
<idno type="wicri:Area/Ncbi/Curation">000F00</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000F00</idno>
<idno type="wicri:doubleKey">1542-8877::Ma K:scleral:fixation:of</idno>
<idno type="wicri:Area/Main/Merge">00B071</idno>
<idno type="wicri:Area/Main/Curation">00A526</idno>
<idno type="wicri:Area/Main/Exploration">00A526</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">Scleral fixation of a silicone plate haptic intraocular lens in a patient showing repeated pupillary intraocular lens capture.</title>
<author><name sortKey="Ma, Kyoung Tak" sort="Ma, Kyoung Tak" uniqKey="Ma K" first="Kyoung Tak" last="Ma">Kyoung Tak Ma</name>
<affiliation wicri:level="3"><nlm:affiliation>Siloam Eye Hospital, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, Korea.</nlm:affiliation>
<country xml:lang="fr">Corée du Sud</country>
<wicri:regionArea>Siloam Eye Hospital, Department of Ophthalmology, Yonsei University College of Medicine, Seoul</wicri:regionArea>
<placeName><settlement type="city">Séoul</settlement>
</placeName>
</affiliation>
</author>
<author><name sortKey="Kim, Sung Soo" sort="Kim, Sung Soo" uniqKey="Kim S" first="Sung Soo" last="Kim">Sung Soo Kim</name>
</author>
<author><name sortKey="Seong, Gong Jae" sort="Seong, Gong Jae" uniqKey="Seong G" first="Gong Jae" last="Seong">Gong Jae Seong</name>
</author>
<author><name sortKey="Lee, Hyung Keun" sort="Lee, Hyung Keun" uniqKey="Lee H" first="Hyung Keun" last="Lee">Hyung Keun Lee</name>
</author>
<author><name sortKey="Kim, Chan Yun" sort="Kim, Chan Yun" uniqKey="Kim C" first="Chan Yun" last="Kim">Chan Yun Kim</name>
</author>
</analytic>
<series><title level="j">Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye</title>
<idno type="ISSN">1542-8877</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Adult</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular (methods)</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Marfan Syndrome (complications)</term>
<term>Pupil Disorders (etiology)</term>
<term>Recurrence</term>
<term>Sclera (surgery)</term>
<term>Silicone Elastomers</term>
<term>Suture Techniques</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" type="chemical" xml:lang="en"><term>Silicone Elastomers</term>
</keywords>
<keywords scheme="MESH" qualifier="complications" xml:lang="en"><term>Marfan Syndrome</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en"><term>Pupil Disorders</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en"><term>Lens Implantation, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en"><term>Sclera</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Adult</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Recurrence</term>
<term>Suture Techniques</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">A 39-year-old man with Marfan syndrome underwent scleral fixation using a three-piece foldable intraocular lens and experienced repeated pupillary intraocular lens captures secondary to a pliable iris. As a result, the patient needed an additional pupilloplasty. In the opposite eye, a silicone plate haptic intraocular lens was used for scleral fixation because it was thought that the plate design could prevent pupillary intraocular lens capture, even in cases involving a pliable iris. At the 27-month follow-up examination, the patient showed good centration of the intraocular lens in the eye that used the silicone plate haptic intraocular lens without pupillary intraocular lens capture.</div>
</front>
</TEI>
<affiliations><list><country><li>Corée du Sud</li>
</country>
<settlement><li>Séoul</li>
</settlement>
</list>
<tree><noCountry><name sortKey="Kim, Chan Yun" sort="Kim, Chan Yun" uniqKey="Kim C" first="Chan Yun" last="Kim">Chan Yun Kim</name>
<name sortKey="Kim, Sung Soo" sort="Kim, Sung Soo" uniqKey="Kim S" first="Sung Soo" last="Kim">Sung Soo Kim</name>
<name sortKey="Lee, Hyung Keun" sort="Lee, Hyung Keun" uniqKey="Lee H" first="Hyung Keun" last="Lee">Hyung Keun Lee</name>
<name sortKey="Seong, Gong Jae" sort="Seong, Gong Jae" uniqKey="Seong G" first="Gong Jae" last="Seong">Gong Jae Seong</name>
</noCountry>
<country name="Corée du Sud"><noRegion><name sortKey="Ma, Kyoung Tak" sort="Ma, Kyoung Tak" uniqKey="Ma K" first="Kyoung Tak" last="Ma">Kyoung Tak Ma</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 00A526 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 00A526 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Exploration |type= RBID |clé= pubmed:18717443 |texte= Scleral fixation of a silicone plate haptic intraocular lens in a patient showing repeated pupillary intraocular lens capture. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i -Sk "pubmed:18717443" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
![]() | This area was generated with Dilib version V0.6.23. | ![]() |