Late spontaneous haptic disinsertion from a three-piece intraocular lens
Identifieur interne : 005989 ( Main/Exploration ); précédent : 005988; suivant : 005990Late spontaneous haptic disinsertion from a three-piece intraocular lens
Auteurs : Joel M. Solano [États-Unis] ; Keith H. Baratz [États-Unis] ; Michael A. Mahr [États-Unis] ; Jay C. Erie [États-Unis]Source :
- American journal of ophthalmology [ 0002-9394 ] ; 2007.
Descripteurs français
- Pascal (Inist)
English descriptors
- KwdEn :
- Aged, Anterior Chamber (pathology), Device Removal, Female, Foreign-Body Migration (etiology), Foreign-Body Migration (surgery), Humans, Intraocular lens, Late, Lens Implantation, Intraocular, Lenses, Intraocular, Male, Ophthalmology, Phacoemulsification, Postoperative Complications, Reoperation, Spontaneous, Treatment.
- MESH :
- etiology : Foreign-Body Migration.
- pathology : Anterior Chamber.
- surgery : Foreign-Body Migration.
- Aged, Device Removal, Female, Humans, Lens Implantation, Intraocular, Lenses, Intraocular, Male, Phacoemulsification, Postoperative Complications, Reoperation.
Abstract
PURPOSE: To report two cases of spontaneous, late-onset haptic disinsertion from a three-piece posterior chamber intraocular lens (IOL). DESIGN: Interventional case reports. METHODS: Two eyes of two patients had uncomplicated phacoemulsification and presented 16 and 20 years after surgery with spontaneous, nontraumatic haptic disinsertion from a three-piece IOL. RESULTS: In one case, the disinserted haptic dislocated into the anterior chamber while the IOL optic-single haptic complex remained centered and supported within the capsular bag. Cystoid macular edema was present, but resolved after removal of the disinserted haptic. In the second case, the disinserted haptic remained within the capsular bag while the IOL optic dislocated into the anterior chamber. Removal of the IOL and exchange with a sulcus-fixated single piece IOL was required. CONCLUSIONS: Nontraumatic haptic disinsertion from a three-piece IOL is a rare long-term complication after phacoemulsification.
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream PascalFrancis, to step Corpus: 000B38
- to stream PascalFrancis, to step Curation: 000957
- to stream PascalFrancis, to step Checkpoint: 000811
- to stream Main, to step Merge: 005B83
- to stream PubMed, to step Corpus: 001687
- to stream PubMed, to step Curation: 001687
- to stream PubMed, to step Checkpoint: 001413
- to stream Ncbi, to step Merge: 000A87
- to stream Ncbi, to step Curation: 000A87
- to stream Ncbi, to step Checkpoint: 000A87
- to stream Main, to step Merge: 005550
- to stream Main, to step Curation: 005989
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en" level="a">Late spontaneous haptic disinsertion from a three-piece intraocular lens</title>
<author><name sortKey="Solano, Joel M" sort="Solano, Joel M" uniqKey="Solano J" first="Joel M." last="Solano">Joel M. Solano</name>
<affiliation wicri:level="2"><inist:fA14 i1="01"><s1>Department of Ophthalmology, Mayo Clinic College of Medicine</s1>
<s2>Rochester, Minnesota</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
<sZ>4 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName><region type="state">Minnesota</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Baratz, Keith H" sort="Baratz, Keith H" uniqKey="Baratz K" first="Keith H." last="Baratz">Keith H. Baratz</name>
<affiliation wicri:level="2"><inist:fA14 i1="01"><s1>Department of Ophthalmology, Mayo Clinic College of Medicine</s1>
<s2>Rochester, Minnesota</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
<sZ>4 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName><region type="state">Minnesota</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Mahr, Michael A" sort="Mahr, Michael A" uniqKey="Mahr M" first="Michael A." last="Mahr">Michael A. Mahr</name>
<affiliation wicri:level="2"><inist:fA14 i1="01"><s1>Department of Ophthalmology, Mayo Clinic College of Medicine</s1>
<s2>Rochester, Minnesota</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
<sZ>4 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName><region type="state">Minnesota</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Erie, Jay C" sort="Erie, Jay C" uniqKey="Erie J" first="Jay C." last="Erie">Jay C. Erie</name>
<affiliation wicri:level="2"><inist:fA14 i1="01"><s1>Department of Ophthalmology, Mayo Clinic College of Medicine</s1>
<s2>Rochester, Minnesota</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
<sZ>4 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName><region type="state">Minnesota</region>
</placeName>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">INIST</idno>
<idno type="inist">07-0312428</idno>
<date when="2007">2007</date>
<idno type="stanalyst">PASCAL 07-0312428 INIST</idno>
<idno type="RBID">Pascal:07-0312428</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000B38</idno>
<idno type="wicri:Area/PascalFrancis/Curation">000957</idno>
<idno type="wicri:Area/PascalFrancis/Checkpoint">000811</idno>
<idno type="wicri:doubleKey">0002-9394:2007:Solano J:late:spontaneous:haptic</idno>
<idno type="wicri:Area/Main/Merge">005B83</idno>
<idno type="wicri:source">PubMed</idno>
<idno type="RBID">pubmed:17317403</idno>
<idno type="wicri:Area/PubMed/Corpus">001687</idno>
<idno type="wicri:Area/PubMed/Curation">001687</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001413</idno>
<idno type="wicri:Area/Ncbi/Merge">000A87</idno>
<idno type="wicri:Area/Ncbi/Curation">000A87</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000A87</idno>
<idno type="wicri:doubleKey">0002-9394:2007:Solano J:late:spontaneous:haptic</idno>
<idno type="wicri:Area/Main/Merge">005550</idno>
<idno type="wicri:Area/Main/Curation">005989</idno>
<idno type="wicri:Area/Main/Exploration">005989</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a">Late spontaneous haptic disinsertion from a three-piece intraocular lens</title>
<author><name sortKey="Solano, Joel M" sort="Solano, Joel M" uniqKey="Solano J" first="Joel M." last="Solano">Joel M. Solano</name>
<affiliation wicri:level="2"><inist:fA14 i1="01"><s1>Department of Ophthalmology, Mayo Clinic College of Medicine</s1>
<s2>Rochester, Minnesota</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
<sZ>4 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName><region type="state">Minnesota</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Baratz, Keith H" sort="Baratz, Keith H" uniqKey="Baratz K" first="Keith H." last="Baratz">Keith H. Baratz</name>
<affiliation wicri:level="2"><inist:fA14 i1="01"><s1>Department of Ophthalmology, Mayo Clinic College of Medicine</s1>
<s2>Rochester, Minnesota</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
<sZ>4 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName><region type="state">Minnesota</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Mahr, Michael A" sort="Mahr, Michael A" uniqKey="Mahr M" first="Michael A." last="Mahr">Michael A. Mahr</name>
<affiliation wicri:level="2"><inist:fA14 i1="01"><s1>Department of Ophthalmology, Mayo Clinic College of Medicine</s1>
<s2>Rochester, Minnesota</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
<sZ>4 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName><region type="state">Minnesota</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Erie, Jay C" sort="Erie, Jay C" uniqKey="Erie J" first="Jay C." last="Erie">Jay C. Erie</name>
<affiliation wicri:level="2"><inist:fA14 i1="01"><s1>Department of Ophthalmology, Mayo Clinic College of Medicine</s1>
<s2>Rochester, Minnesota</s2>
<s3>USA</s3>
<sZ>1 aut.</sZ>
<sZ>2 aut.</sZ>
<sZ>3 aut.</sZ>
<sZ>4 aut.</sZ>
</inist:fA14>
<country>États-Unis</country>
<placeName><region type="state">Minnesota</region>
</placeName>
</affiliation>
</author>
</analytic>
<series><title level="j" type="main">American journal of ophthalmology</title>
<title level="j" type="abbreviated">Am. j. ophthalmol.</title>
<idno type="ISSN">0002-9394</idno>
<imprint><date when="2007">2007</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><title level="j" type="main">American journal of ophthalmology</title>
<title level="j" type="abbreviated">Am. j. ophthalmol.</title>
<idno type="ISSN">0002-9394</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Aged</term>
<term>Anterior Chamber (pathology)</term>
<term>Device Removal</term>
<term>Female</term>
<term>Foreign-Body Migration (etiology)</term>
<term>Foreign-Body Migration (surgery)</term>
<term>Humans</term>
<term>Intraocular lens</term>
<term>Late</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Ophthalmology</term>
<term>Phacoemulsification</term>
<term>Postoperative Complications</term>
<term>Reoperation</term>
<term>Spontaneous</term>
<term>Treatment</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en"><term>Foreign-Body Migration</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en"><term>Anterior Chamber</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en"><term>Foreign-Body Migration</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Aged</term>
<term>Device Removal</term>
<term>Female</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Phacoemulsification</term>
<term>Postoperative Complications</term>
<term>Reoperation</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr"><term>Tardif</term>
<term>Spontané</term>
<term>Lentille intraoculaire</term>
<term>Ophtalmologie</term>
<term>Traitement</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">PURPOSE: To report two cases of spontaneous, late-onset haptic disinsertion from a three-piece posterior chamber intraocular lens (IOL). DESIGN: Interventional case reports. METHODS: Two eyes of two patients had uncomplicated phacoemulsification and presented 16 and 20 years after surgery with spontaneous, nontraumatic haptic disinsertion from a three-piece IOL. RESULTS: In one case, the disinserted haptic dislocated into the anterior chamber while the IOL optic-single haptic complex remained centered and supported within the capsular bag. Cystoid macular edema was present, but resolved after removal of the disinserted haptic. In the second case, the disinserted haptic remained within the capsular bag while the IOL optic dislocated into the anterior chamber. Removal of the IOL and exchange with a sulcus-fixated single piece IOL was required. CONCLUSIONS: Nontraumatic haptic disinsertion from a three-piece IOL is a rare long-term complication after phacoemulsification.</div>
</front>
</TEI>
<affiliations><list><country><li>États-Unis</li>
</country>
<region><li>Minnesota</li>
</region>
</list>
<tree><country name="États-Unis"><region name="Minnesota"><name sortKey="Solano, Joel M" sort="Solano, Joel M" uniqKey="Solano J" first="Joel M." last="Solano">Joel M. Solano</name>
</region>
<name sortKey="Baratz, Keith H" sort="Baratz, Keith H" uniqKey="Baratz K" first="Keith H." last="Baratz">Keith H. Baratz</name>
<name sortKey="Erie, Jay C" sort="Erie, Jay C" uniqKey="Erie J" first="Jay C." last="Erie">Jay C. Erie</name>
<name sortKey="Mahr, Michael A" sort="Mahr, Michael A" uniqKey="Mahr M" first="Michael A." last="Mahr">Michael A. Mahr</name>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 005989 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 005989 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Exploration |type= RBID |clé= Pascal:07-0312428 |texte= Late spontaneous haptic disinsertion from a three-piece intraocular lens }}
This area was generated with Dilib version V0.6.23. |