Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Second generation haptic ventriculostomy simulator using the ImmersiveTouch system.

Identifieur interne : 005B42 ( Main/Exploration ); précédent : 005B41; suivant : 005B43

Second generation haptic ventriculostomy simulator using the ImmersiveTouch system.

Auteurs : Cristian Luciano [États-Unis] ; Pat Banerjee ; G Michael Lemole ; Fady Charbel

Source :

RBID : pubmed:16404075

Descripteurs français

English descriptors

Abstract

Ventriculostomy is a neurosurgical procedure that consists of the insertion of a catheter into the ventricles of the brain for relieving the intracranial pressure. A distinct "popping" sensation is felt as the catheter enters the ventricles. Early ventriculostomy simulators provided some basic audio/visual feedback to simulate the procedure, displaying a 3D virtual model of a human head. Without any tactile feedback, the usefulness of such simulators was very limited. The first generation haptic ventriculostomy simulators incorporated a haptic device to generate a virtual resistance and "give" upon ventricular entry. While this created considerable excitement as a novelty device for cannulating ventricles, its usefulness for teaching and measuring neurosurgical expertise was still very limited. Poor collocation between the haptic device stylus held by the surgeon and the visual representation of the virtual catheter, as well as the lack of a correct viewer-centered perspective, created enormous confusion for the neurosurgeons who diverted their attention from the actual ventriculostomy procedure to overcoming the limitations of the simulator. We present a second generation haptic ventriculostomy simulator succeeding over the major first generation limitations by introducing a head and hand tracking system as well as a high-resolution high-visual-acuity stereoscopic display to enhance the perception and realism of the virtual ventriculostomy.

PubMed: 16404075


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Second generation haptic ventriculostomy simulator using the ImmersiveTouch system.</title>
<author>
<name sortKey="Luciano, Cristian" sort="Luciano, Cristian" uniqKey="Luciano C" first="Cristian" last="Luciano">Cristian Luciano</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Computer Science, University of Illinois at Chicago, USA. clucia1@uic.edu</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Computer Science, University of Illinois at Chicago</wicri:regionArea>
<wicri:noRegion>University of Illinois at Chicago</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Banerjee, Pat" sort="Banerjee, Pat" uniqKey="Banerjee P" first="Pat" last="Banerjee">Pat Banerjee</name>
</author>
<author>
<name sortKey="Lemole, G Michael" sort="Lemole, G Michael" uniqKey="Lemole G" first="G Michael" last="Lemole">G Michael Lemole</name>
</author>
<author>
<name sortKey="Charbel, Fady" sort="Charbel, Fady" uniqKey="Charbel F" first="Fady" last="Charbel">Fady Charbel</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2006">2006</date>
<idno type="RBID">pubmed:16404075</idno>
<idno type="pmid">16404075</idno>
<idno type="wicri:Area/PubMed/Corpus">001857</idno>
<idno type="wicri:Area/PubMed/Curation">001857</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001541</idno>
<idno type="wicri:Area/Ncbi/Merge">000851</idno>
<idno type="wicri:Area/Ncbi/Curation">000851</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000851</idno>
<idno type="wicri:doubleKey">0926-9630:2006:Luciano C:second:generation:haptic</idno>
<idno type="wicri:Area/Main/Merge">005D52</idno>
<idno type="wicri:Area/Main/Curation">005B42</idno>
<idno type="wicri:Area/Main/Exploration">005B42</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Second generation haptic ventriculostomy simulator using the ImmersiveTouch system.</title>
<author>
<name sortKey="Luciano, Cristian" sort="Luciano, Cristian" uniqKey="Luciano C" first="Cristian" last="Luciano">Cristian Luciano</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Computer Science, University of Illinois at Chicago, USA. clucia1@uic.edu</nlm:affiliation>
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Computer Science, University of Illinois at Chicago</wicri:regionArea>
<wicri:noRegion>University of Illinois at Chicago</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Banerjee, Pat" sort="Banerjee, Pat" uniqKey="Banerjee P" first="Pat" last="Banerjee">Pat Banerjee</name>
</author>
<author>
<name sortKey="Lemole, G Michael" sort="Lemole, G Michael" uniqKey="Lemole G" first="G Michael" last="Lemole">G Michael Lemole</name>
</author>
<author>
<name sortKey="Charbel, Fady" sort="Charbel, Fady" uniqKey="Charbel F" first="Fady" last="Charbel">Fady Charbel</name>
</author>
</analytic>
<series>
<title level="j">Studies in health technology and informatics</title>
<idno type="ISSN">0926-9630</idno>
<imprint>
<date when="2006" type="published">2006</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Computer Simulation</term>
<term>Humans</term>
<term>Image Processing, Computer-Assisted</term>
<term>Touch</term>
<term>United States</term>
<term>Ventriculostomy</term>
</keywords>
<keywords scheme="MESH" type="geographic" xml:lang="en">
<term>United States</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Computer Simulation</term>
<term>Humans</term>
<term>Image Processing, Computer-Assisted</term>
<term>Touch</term>
<term>Ventriculostomy</term>
</keywords>
<keywords scheme="Wicri" type="geographic" xml:lang="fr">
<term>États-Unis</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Ventriculostomy is a neurosurgical procedure that consists of the insertion of a catheter into the ventricles of the brain for relieving the intracranial pressure. A distinct "popping" sensation is felt as the catheter enters the ventricles. Early ventriculostomy simulators provided some basic audio/visual feedback to simulate the procedure, displaying a 3D virtual model of a human head. Without any tactile feedback, the usefulness of such simulators was very limited. The first generation haptic ventriculostomy simulators incorporated a haptic device to generate a virtual resistance and "give" upon ventricular entry. While this created considerable excitement as a novelty device for cannulating ventricles, its usefulness for teaching and measuring neurosurgical expertise was still very limited. Poor collocation between the haptic device stylus held by the surgeon and the visual representation of the virtual catheter, as well as the lack of a correct viewer-centered perspective, created enormous confusion for the neurosurgeons who diverted their attention from the actual ventriculostomy procedure to overcoming the limitations of the simulator. We present a second generation haptic ventriculostomy simulator succeeding over the major first generation limitations by introducing a head and hand tracking system as well as a high-resolution high-visual-acuity stereoscopic display to enhance the perception and realism of the virtual ventriculostomy.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>États-Unis</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Banerjee, Pat" sort="Banerjee, Pat" uniqKey="Banerjee P" first="Pat" last="Banerjee">Pat Banerjee</name>
<name sortKey="Charbel, Fady" sort="Charbel, Fady" uniqKey="Charbel F" first="Fady" last="Charbel">Fady Charbel</name>
<name sortKey="Lemole, G Michael" sort="Lemole, G Michael" uniqKey="Lemole G" first="G Michael" last="Lemole">G Michael Lemole</name>
</noCountry>
<country name="États-Unis">
<noRegion>
<name sortKey="Luciano, Cristian" sort="Luciano, Cristian" uniqKey="Luciano C" first="Cristian" last="Luciano">Cristian Luciano</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 005B42 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 005B42 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:16404075
   |texte=   Second generation haptic ventriculostomy simulator using the ImmersiveTouch system.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:16404075" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024