[Spontaneous fracture of an implanted anterior chamber lens].

Identifieur interne : 009493 ( Main/Exploration ); précédent : 009492; suivant : 009494

[Spontaneous fracture of an implanted anterior chamber lens].

Auteurs : C. Weickert ; G. Fuhrmann ; H. Bleckmann

Source :

RBID : pubmed:1304213

English descriptors

Abstract

This report deals with an 83-year-old patient who presented with visual deterioration. The patient had had an intracapsulary extraction with anterior chamber lens implantation. The break in the anterior chamber lens happened without any history of traumatic accident and led to dislocation of the lens and corneal decompensation. Scanning electron microscopy of the break area after explantation of the fragments revealed changes in the break zone that were characteristic of alternating tensile and compressive stress. Localization of the break at the transition of the optical part and the haptic where there is the greatest stress in the material points to insufficient strengthening in this critical part of the intraocular lens.

PubMed: 1304213


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">[Spontaneous fracture of an implanted anterior chamber lens].</title>
<author>
<name sortKey="Weickert, C" sort="Weickert, C" uniqKey="Weickert C" first="C" last="Weickert">C. Weickert</name>
<affiliation>
<nlm:affiliation>Augenabteilung der Schlosspark-Klinik Berlin.</nlm:affiliation>
<wicri:noCountry code="no comma">Augenabteilung der Schlosspark-Klinik Berlin.</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Fuhrmann, G" sort="Fuhrmann, G" uniqKey="Fuhrmann G" first="G" last="Fuhrmann">G. Fuhrmann</name>
</author>
<author>
<name sortKey="Bleckmann, H" sort="Bleckmann, H" uniqKey="Bleckmann H" first="H" last="Bleckmann">H. Bleckmann</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1992">1992</date>
<idno type="RBID">pubmed:1304213</idno>
<idno type="pmid">1304213</idno>
<idno type="wicri:Area/PubMed/Corpus">002190</idno>
<idno type="wicri:Area/PubMed/Curation">002190</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001F05</idno>
<idno type="wicri:Area/Ncbi/Merge">000413</idno>
<idno type="wicri:Area/Ncbi/Curation">000413</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000413</idno>
<idno type="wicri:doubleKey">0941-293X:1992:Weickert C:spontaneous:fracture:of</idno>
<idno type="wicri:Area/Main/Merge">009E96</idno>
<idno type="wicri:Area/Main/Curation">009493</idno>
<idno type="wicri:Area/Main/Exploration">009493</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">[Spontaneous fracture of an implanted anterior chamber lens].</title>
<author>
<name sortKey="Weickert, C" sort="Weickert, C" uniqKey="Weickert C" first="C" last="Weickert">C. Weickert</name>
<affiliation>
<nlm:affiliation>Augenabteilung der Schlosspark-Klinik Berlin.</nlm:affiliation>
<wicri:noCountry code="no comma">Augenabteilung der Schlosspark-Klinik Berlin.</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Fuhrmann, G" sort="Fuhrmann, G" uniqKey="Fuhrmann G" first="G" last="Fuhrmann">G. Fuhrmann</name>
</author>
<author>
<name sortKey="Bleckmann, H" sort="Bleckmann, H" uniqKey="Bleckmann H" first="H" last="Bleckmann">H. Bleckmann</name>
</author>
</analytic>
<series>
<title level="j">Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft</title>
<idno type="ISSN">0941-293X</idno>
<imprint>
<date when="1992" type="published">1992</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Anterior Chamber (surgery)</term>
<term>Eye Foreign Bodies (surgery)</term>
<term>Female</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Microscopy, Electron, Scanning</term>
<term>Postoperative Complications (surgery)</term>
<term>Prosthesis Failure</term>
<term>Surface Properties</term>
<term>Tensile Strength</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Anterior Chamber</term>
<term>Eye Foreign Bodies</term>
<term>Postoperative Complications</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Aged, 80 and over</term>
<term>Female</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Microscopy, Electron, Scanning</term>
<term>Prosthesis Failure</term>
<term>Surface Properties</term>
<term>Tensile Strength</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">This report deals with an 83-year-old patient who presented with visual deterioration. The patient had had an intracapsulary extraction with anterior chamber lens implantation. The break in the anterior chamber lens happened without any history of traumatic accident and led to dislocation of the lens and corneal decompensation. Scanning electron microscopy of the break area after explantation of the fragments revealed changes in the break zone that were characteristic of alternating tensile and compressive stress. Localization of the break at the transition of the optical part and the haptic where there is the greatest stress in the material points to insufficient strengthening in this critical part of the intraocular lens.</div>
</front>
</TEI>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Bleckmann, H" sort="Bleckmann, H" uniqKey="Bleckmann H" first="H" last="Bleckmann">H. Bleckmann</name>
<name sortKey="Fuhrmann, G" sort="Fuhrmann, G" uniqKey="Fuhrmann G" first="G" last="Fuhrmann">G. Fuhrmann</name>
<name sortKey="Weickert, C" sort="Weickert, C" uniqKey="Weickert C" first="C" last="Weickert">C. Weickert</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 009493 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 009493 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:1304213
   |texte=   [Spontaneous fracture of an implanted anterior chamber lens].
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:1304213" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024