Repositioning a subluxated sutured intraocular lens in a vitrectomized eye
Identifieur interne : 007D08 ( Main/Exploration ); précédent : 007D07; suivant : 007D09Repositioning a subluxated sutured intraocular lens in a vitrectomized eye
Auteurs : Shih-Chung Lee [République populaire de Chine] ; Fred Kuanfu Chen [République populaire de Chine] ; Sung-Huei Tseng [Taïwan, République populaire de Chine] ; Hon-Chun Cheng [République populaire de Chine]Source :
- Journal of Cataract & Refractive Surgery [ 0886-3350 ] ; 2000.
Descripteurs français
- Pascal (Inist)
- Wicri :
- topic : Homme.
English descriptors
- KwdEn :
- Case study, Complication, Eye, Eye Injuries (surgery), Foreign-Body Migration (etiology), Foreign-Body Migration (surgery), Human, Humans, Intraocular lens, Lens, Crystalline (injuries), Lens, Crystalline (surgery), Lenses, Intraocular (adverse effects), Luxation, Male, Middle Aged, Pars plana, Posterior chamber, Reoperation, Replantation, Sclera (surgery), Surgical approach, Suturation, Suture Techniques (adverse effects), Technique, Visual Acuity, Vitrectomy, Wounds, Nonpenetrating (surgery).
- MESH :
- adverse effects : Lenses, Intraocular, Suture Techniques.
- etiology : Foreign-Body Migration.
- injuries : Lens, Crystalline.
- surgery : Eye Injuries, Foreign-Body Migration, Lens, Crystalline, Sclera, Wounds, Nonpenetrating.
- Humans, Male, Middle Aged, Reoperation, Visual Acuity, Vitrectomy.
Abstract
A simple, effective technique for repositioning a subluxated intraocular lens (IOL) in a vitrectomized eye is reported. A 49-year-old man who had previous pars plana vitrectomy and transscleral suture fixation of a posterior chamber (PC) IOL had lens subluxation caused by slippage of the haptic from a fixation suture. The IOL was dangling in the liquefied vitreous, preventing direct visualization of the displaced haptic. The displaced haptic was directly grasped from the opposite side with an intraocular forceps through a limbal wound and resutured to the sclera. Because only the end-grip intraocular forceps was required, this technique provides anterior segment surgeons an alternative technique of repositioning scleral-fixated PC IOLs.
Url:
DOI: 10.1016/S0886-3350(00)00476-4
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: 000557
- to stream Istex, to step Curation: 000557
- to stream Istex, to step Checkpoint: 003048
- to stream Main, to step Merge: 008395
- to stream PascalFrancis, to step Corpus: 001431
- to stream PascalFrancis, to step Curation: 000081
- to stream PascalFrancis, to step Checkpoint: 001196
- to stream Main, to step Merge: 008657
- to stream PubMed, to step Corpus: 001E03
- to stream PubMed, to step Curation: 001E03
- to stream PubMed, to step Checkpoint: 001B48
- to stream Ncbi, to step Merge: 000155
- to stream Ncbi, to step Curation: 000155
- to stream Ncbi, to step Checkpoint: 000155
- to stream Main, to step Merge: 008183
- to stream Main, to step Curation: 007D08
Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Repositioning a subluxated sutured intraocular lens in a vitrectomized eye</title>
<author><name sortKey="Lee, Shih Chung" sort="Lee, Shih Chung" uniqKey="Lee S" first="Shih-Chung" last="Lee">Shih-Chung Lee</name>
</author>
<author><name sortKey="Chen, Fred Kuanfu" sort="Chen, Fred Kuanfu" uniqKey="Chen F" first="Fred Kuanfu" last="Chen">Fred Kuanfu Chen</name>
</author>
<author><name sortKey="Tseng, Sung Huei" sort="Tseng, Sung Huei" uniqKey="Tseng S" first="Sung-Huei" last="Tseng">Sung-Huei Tseng</name>
</author>
<author><name sortKey="Cheng, Hon Chun" sort="Cheng, Hon Chun" uniqKey="Cheng H" first="Hon-Chun" last="Cheng">Hon-Chun Cheng</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:21736A4010374FE5B5042D11B1DAAEEC0719F4AD</idno>
<date when="2000" year="2000">2000</date>
<idno type="doi">10.1016/S0886-3350(00)00476-4</idno>
<idno type="url">https://api.istex.fr/document/21736A4010374FE5B5042D11B1DAAEEC0719F4AD/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000557</idno>
<idno type="wicri:Area/Istex/Curation">000557</idno>
<idno type="wicri:Area/Istex/Checkpoint">003048</idno>
<idno type="wicri:doubleKey">0886-3350:2000:Lee S:repositioning:a:subluxated</idno>
<idno type="wicri:Area/Main/Merge">008395</idno>
<idno type="wicri:source">INIST</idno>
<idno type="RBID">Pascal:01-0102942</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">001431</idno>
<idno type="wicri:Area/PascalFrancis/Curation">000081</idno>
<idno type="wicri:Area/PascalFrancis/Checkpoint">001196</idno>
<idno type="wicri:doubleKey">0886-3350:2000:Lee S:repositioning:a:subluxated</idno>
<idno type="wicri:Area/Main/Merge">008657</idno>
<idno type="wicri:source">PubMed</idno>
<idno type="RBID">pubmed:11084262</idno>
<idno type="wicri:Area/PubMed/Corpus">001E03</idno>
<idno type="wicri:Area/PubMed/Curation">001E03</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001B48</idno>
<idno type="wicri:Area/Ncbi/Merge">000155</idno>
<idno type="wicri:Area/Ncbi/Curation">000155</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000155</idno>
<idno type="wicri:doubleKey">0886-3350:2000:Lee S:repositioning:a:subluxated</idno>
<idno type="wicri:Area/Main/Merge">008183</idno>
<idno type="wicri:Area/Main/Curation">007D08</idno>
<idno type="wicri:Area/Main/Exploration">007D08</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main" xml:lang="en">Repositioning a subluxated sutured intraocular lens in a vitrectomized eye</title>
<author><name sortKey="Lee, Shih Chung" sort="Lee, Shih Chung" uniqKey="Lee S" first="Shih-Chung" last="Lee">Shih-Chung Lee</name>
<affiliation wicri:level="1"><country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Department of Ophthalmology, College of Medicine, National Cheng Kung University, Tainan, Taiwan</wicri:regionArea>
<wicri:noRegion>Taiwan</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Chen, Fred Kuanfu" sort="Chen, Fred Kuanfu" uniqKey="Chen F" first="Fred Kuanfu" last="Chen">Fred Kuanfu Chen</name>
<affiliation wicri:level="1"><country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Department of Ophthalmology, College of Medicine, National Cheng Kung University, Tainan, Taiwan</wicri:regionArea>
<wicri:noRegion>Taiwan</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Tseng, Sung Huei" sort="Tseng, Sung Huei" uniqKey="Tseng S" first="Sung-Huei" last="Tseng">Sung-Huei Tseng</name>
<affiliation wicri:level="1"><country wicri:rule="url">Taïwan</country>
</affiliation>
<affiliation wicri:level="1"><country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Department of Ophthalmology, College of Medicine, National Cheng Kung University, Tainan, Taiwan</wicri:regionArea>
<wicri:noRegion>Taiwan</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Cheng, Hon Chun" sort="Cheng, Hon Chun" uniqKey="Cheng H" first="Hon-Chun" last="Cheng">Hon-Chun Cheng</name>
<affiliation wicri:level="1"><country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Department of Ophthalmology, College of Medicine, National Cheng Kung University, Tainan, Taiwan</wicri:regionArea>
<wicri:noRegion>Taiwan</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j">Journal of Cataract & Refractive Surgery</title>
<title level="j" type="abbrev">JCRS</title>
<idno type="ISSN">0886-3350</idno>
<imprint><publisher>ELSEVIER</publisher>
<date type="published" when="2000">2000</date>
<biblScope unit="volume">26</biblScope>
<biblScope unit="issue">11</biblScope>
<biblScope unit="page" from="1577">1577</biblScope>
<biblScope unit="page" to="1580">1580</biblScope>
</imprint>
<idno type="ISSN">0886-3350</idno>
</series>
<idno type="istex">21736A4010374FE5B5042D11B1DAAEEC0719F4AD</idno>
<idno type="DOI">10.1016/S0886-3350(00)00476-4</idno>
<idno type="PII">S0886-3350(00)00476-4</idno>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0886-3350</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Case study</term>
<term>Complication</term>
<term>Eye</term>
<term>Eye Injuries (surgery)</term>
<term>Foreign-Body Migration (etiology)</term>
<term>Foreign-Body Migration (surgery)</term>
<term>Human</term>
<term>Humans</term>
<term>Intraocular lens</term>
<term>Lens, Crystalline (injuries)</term>
<term>Lens, Crystalline (surgery)</term>
<term>Lenses, Intraocular (adverse effects)</term>
<term>Luxation</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Pars plana</term>
<term>Posterior chamber</term>
<term>Reoperation</term>
<term>Replantation</term>
<term>Sclera (surgery)</term>
<term>Surgical approach</term>
<term>Suturation</term>
<term>Suture Techniques (adverse effects)</term>
<term>Technique</term>
<term>Visual Acuity</term>
<term>Vitrectomy</term>
<term>Wounds, Nonpenetrating (surgery)</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en"><term>Lenses, Intraocular</term>
<term>Suture Techniques</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en"><term>Foreign-Body Migration</term>
</keywords>
<keywords scheme="MESH" qualifier="injuries" xml:lang="en"><term>Lens, Crystalline</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en"><term>Eye Injuries</term>
<term>Foreign-Body Migration</term>
<term>Lens, Crystalline</term>
<term>Sclera</term>
<term>Wounds, Nonpenetrating</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Humans</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Reoperation</term>
<term>Visual Acuity</term>
<term>Vitrectomy</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr"><term>Chambre postérieure</term>
<term>Complication</term>
<term>Etude cas</term>
<term>Homme</term>
<term>Lentille intraoculaire</term>
<term>Luxation</term>
<term>Oeil</term>
<term>Pars plana</term>
<term>Réimplantation</term>
<term>Suture chirurgicale</term>
<term>Technique</term>
<term>Vitrectomie</term>
<term>Voie abord</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr"><term>Homme</term>
</keywords>
</textClass>
<langUsage><language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">A simple, effective technique for repositioning a subluxated intraocular lens (IOL) in a vitrectomized eye is reported. A 49-year-old man who had previous pars plana vitrectomy and transscleral suture fixation of a posterior chamber (PC) IOL had lens subluxation caused by slippage of the haptic from a fixation suture. The IOL was dangling in the liquefied vitreous, preventing direct visualization of the displaced haptic. The displaced haptic was directly grasped from the opposite side with an intraocular forceps through a limbal wound and resutured to the sclera. Because only the end-grip intraocular forceps was required, this technique provides anterior segment surgeons an alternative technique of repositioning scleral-fixated PC IOLs.</div>
</front>
</TEI>
<affiliations><list><country><li>République populaire de Chine</li>
<li>Taïwan</li>
</country>
</list>
<tree><country name="République populaire de Chine"><noRegion><name sortKey="Lee, Shih Chung" sort="Lee, Shih Chung" uniqKey="Lee S" first="Shih-Chung" last="Lee">Shih-Chung Lee</name>
</noRegion>
<name sortKey="Chen, Fred Kuanfu" sort="Chen, Fred Kuanfu" uniqKey="Chen F" first="Fred Kuanfu" last="Chen">Fred Kuanfu Chen</name>
<name sortKey="Cheng, Hon Chun" sort="Cheng, Hon Chun" uniqKey="Cheng H" first="Hon-Chun" last="Cheng">Hon-Chun Cheng</name>
<name sortKey="Tseng, Sung Huei" sort="Tseng, Sung Huei" uniqKey="Tseng S" first="Sung-Huei" last="Tseng">Sung-Huei Tseng</name>
</country>
<country name="Taïwan"><noRegion><name sortKey="Tseng, Sung Huei" sort="Tseng, Sung Huei" uniqKey="Tseng S" first="Sung-Huei" last="Tseng">Sung-Huei Tseng</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 007D08 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 007D08 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:21736A4010374FE5B5042D11B1DAAEEC0719F4AD |texte= Repositioning a subluxated sutured intraocular lens in a vitrectomized eye }}
This area was generated with Dilib version V0.6.23. |