Complications of foldable intraocular lenses requiring explantation or secondary intervention—1998 survey
Identifieur interne : 007B48 ( Main/Exploration ); précédent : 007B47; suivant : 007B49Complications of foldable intraocular lenses requiring explantation or secondary intervention—1998 survey
Auteurs : Nick MamalisSource :
- [ 0886-3350 ]
Descripteurs français
- Pascal (Inist)
- Wicri :
- geographic : États-Unis.
- topic : Homme.
English descriptors
- KwdEn :
- Acrylic Resins (adverse effects), Cataract, Complication, Device Removal, Health Surveys, Human, Humans, Intraocular lens, Lenses, Intraocular (adverse effects), Ophthalmology (statistics & numerical data), Practice Patterns, Physicians', Reoperation, Silicone Elastomers (adverse effects), Societies, Medical, Surgical implantation, United States.
- MESH :
- chemical , adverse effects : Acrylic Resins, Silicone Elastomers.
- geographic : United States.
- adverse effects : Lenses, Intraocular.
- statistics & numerical data : Ophthalmology.
- Device Removal, Health Surveys, Humans, Practice Patterns, Physicians', Reoperation, Societies, Medical.
Abstract
A survey of the complications associated with foldable intraocular lenses (iols) that required explantation or secondary intervention was sent to domestic members of the american society of cataract and refractive surgery in 1998. preoperative data as well as patient signs and symptoms were obtained and postoperative results and outcomes assessed. the types of foldable iols explanted were tabulated. the percentage of each type removed and the common reasons for removal were as follows 38%—3-piece monofocal silicone IOLs for incorrect lens power followed by dislocation/decentration; 31%—3-piece multifocal silicone IOLs for glare/optical aberrations; 16%—3-piece acrylic IOLs for glare/optical aberrations followed by incorrect lens power and dislocation; 15%—1-piece or plate-haptic silicone IOLs for dislocation/decentration followed by incorrect lens power. Visual outcomes were uniformly good in the 4 groups. Meticulous surgical technique, IOL insertion, and IOL power measurements, along with proper patient selection, are important factors in avoiding complications with foldable IOLs.
Url:
DOI: 10.1016/S0886-3350(00)00424-7
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: 000197
- to stream Istex, to step Curation: 000197
- to stream Istex, to step Checkpoint: 002E86
- to stream Main, to step Merge: 008233
- to stream PascalFrancis, to step Corpus: 001475
- to stream PascalFrancis, to step Curation: 000038
- to stream PascalFrancis, to step Checkpoint: 001237
- to stream Main, to step Merge: 008698
- to stream PubMed, to step Corpus: 001E39
- to stream PubMed, to step Curation: 001E39
- to stream PubMed, to step Checkpoint: 001B87
- to stream Ncbi, to step Merge: 000117
- to stream Ncbi, to step Curation: 000117
- to stream Ncbi, to step Checkpoint: 000117
- to stream Main, to step Merge: 008223
- to stream Main, to step Curation: 007B48
Le document en format XML
<record><TEI wicri:istexFullTextTei="no"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Complications of foldable intraocular lenses requiring explantation or secondary intervention—1998 survey</title>
<author><name sortKey="Mamalis, Nick" sort="Mamalis, Nick" uniqKey="Mamalis N" first="Nick" last="Mamalis">Nick Mamalis</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:281FCFA5DC67A70878355ED6B7DF6A0FB4121BC8</idno>
<date when="2000" year="2000">2000</date>
<idno type="doi">10.1016/S0886-3350(00)00424-7</idno>
<idno type="url">https://api.istex.fr/document/281FCFA5DC67A70878355ED6B7DF6A0FB4121BC8/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000197</idno>
<idno type="wicri:Area/Istex/Curation">000197</idno>
<idno type="wicri:Area/Istex/Checkpoint">002E86</idno>
<idno type="wicri:doubleKey">0886-3350:2000:Mamalis N:complications:of:foldable</idno>
<idno type="wicri:Area/Main/Merge">008233</idno>
<idno type="wicri:source">INIST</idno>
<idno type="RBID">Pascal:00-0303115</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">001475</idno>
<idno type="wicri:Area/PascalFrancis/Curation">000038</idno>
<idno type="wicri:Area/PascalFrancis/Checkpoint">001237</idno>
<idno type="wicri:doubleKey">0886-3350:2000:Mamalis N:complications:of:foldable</idno>
<idno type="wicri:Area/Main/Merge">008698</idno>
<idno type="wicri:source">PubMed</idno>
<idno type="RBID">pubmed:10831909</idno>
<idno type="wicri:Area/PubMed/Corpus">001E39</idno>
<idno type="wicri:Area/PubMed/Curation">001E39</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001B87</idno>
<idno type="wicri:Area/Ncbi/Merge">000117</idno>
<idno type="wicri:Area/Ncbi/Curation">000117</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000117</idno>
<idno type="wicri:doubleKey">0886-3350:2000:Mamalis N:complications:of:foldable</idno>
<idno type="wicri:Area/Main/Merge">008223</idno>
<idno type="wicri:Area/Main/Curation">007B48</idno>
<idno type="wicri:Area/Main/Exploration">007B48</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><author><name sortKey="Mamalis, Nick" sort="Mamalis, Nick" uniqKey="Mamalis N" first="Nick" last="Mamalis">Nick Mamalis</name>
</author>
</analytic>
<series><idno type="ISSN">0886-3350</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0886-3350</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Acrylic Resins (adverse effects)</term>
<term>Cataract</term>
<term>Complication</term>
<term>Device Removal</term>
<term>Health Surveys</term>
<term>Human</term>
<term>Humans</term>
<term>Intraocular lens</term>
<term>Lenses, Intraocular (adverse effects)</term>
<term>Ophthalmology (statistics & numerical data)</term>
<term>Practice Patterns, Physicians'</term>
<term>Reoperation</term>
<term>Silicone Elastomers (adverse effects)</term>
<term>Societies, Medical</term>
<term>Surgical implantation</term>
<term>United States</term>
</keywords>
<keywords scheme="MESH" type="chemical" qualifier="adverse effects" xml:lang="en"><term>Acrylic Resins</term>
<term>Silicone Elastomers</term>
</keywords>
<keywords scheme="MESH" type="geographic" xml:lang="en"><term>United States</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en"><term>Lenses, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="statistics & numerical data" xml:lang="en"><term>Ophthalmology</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Device Removal</term>
<term>Health Surveys</term>
<term>Humans</term>
<term>Practice Patterns, Physicians'</term>
<term>Reoperation</term>
<term>Societies, Medical</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr"><term>Cataracte</term>
<term>Complication</term>
<term>Homme</term>
<term>Implantation chirurgicale</term>
<term>Lentille intraoculaire</term>
<term>Réintervention</term>
</keywords>
<keywords scheme="Wicri" type="geographic" xml:lang="fr"><term>États-Unis</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr"><term>Homme</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">A survey of the complications associated with foldable intraocular lenses (iols) that required explantation or secondary intervention was sent to domestic members of the american society of cataract and refractive surgery in 1998. preoperative data as well as patient signs and symptoms were obtained and postoperative results and outcomes assessed. the types of foldable iols explanted were tabulated. the percentage of each type removed and the common reasons for removal were as follows 38%—3-piece monofocal silicone IOLs for incorrect lens power followed by dislocation/decentration; 31%—3-piece multifocal silicone IOLs for glare/optical aberrations; 16%—3-piece acrylic IOLs for glare/optical aberrations followed by incorrect lens power and dislocation; 15%—1-piece or plate-haptic silicone IOLs for dislocation/decentration followed by incorrect lens power. Visual outcomes were uniformly good in the 4 groups. Meticulous surgical technique, IOL insertion, and IOL power measurements, along with proper patient selection, are important factors in avoiding complications with foldable IOLs.</div>
</front>
</TEI>
<affiliations><list></list>
<tree><noCountry><name sortKey="Mamalis, Nick" sort="Mamalis, Nick" uniqKey="Mamalis N" first="Nick" last="Mamalis">Nick Mamalis</name>
</noCountry>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 007B48 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 007B48 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:281FCFA5DC67A70878355ED6B7DF6A0FB4121BC8 |texte= Complications of foldable intraocular lenses requiring explantation or secondary intervention—1998 survey }}
This area was generated with Dilib version V0.6.23. |