An Ungrounded Hand-Held Surgical Device Incorporating Active Constraints with Force-Feedback

Identifieur interne : 001D70 ( Main/Exploration ); précédent : 001D69; suivant : 001D71

An Ungrounded Hand-Held Surgical Device Incorporating Active Constraints with Force-Feedback

Auteurs : Christopher J. Payne ; Ka-Wai Kwok ; Guang-Zhong Yang

Source :

RBID : PMC:3987169

Abstract

This paper presents an ungrounded, hand-held surgical device that incorporates active constraints and force-feedback. Optical tracking of the device and embedded actuation allow for real-time motion compensation of a surgical tool as an active constraint is encountered. The active constraints can be made soft, so that the surgical tool tip motion is scaled, or rigid, so as to altogether prevent the penetration of the active constraint. Force-feedback is also provided to the operator so as to indicate penetration of the active constraint boundary by the surgical tool. The device has been evaluated in detailed bench tests to quantify its motion scaling and force-feedback capabilities. The combined effects of force-feedback and motion compensation are demonstrated during palpation of an active constraint with rigid and soft boundaries. A user study evaluated the combined effect of motion compensation and force-feedback in preventing penetration of a rigid active constraint. The results have shown the potential of the device operating in an ungrounded setup that incorporates active constraints with force-feedback.


Url:
DOI: 10.1109/IROS.2013.6696717
PubMed: 24744963
PubMed Central: 3987169


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">An Ungrounded Hand-Held Surgical Device Incorporating Active Constraints with Force-Feedback</title>
<author>
<name sortKey="Payne, Christopher J" sort="Payne, Christopher J" uniqKey="Payne C" first="Christopher J." last="Payne">Christopher J. Payne</name>
</author>
<author>
<name sortKey="Kwok, Ka Wai" sort="Kwok, Ka Wai" uniqKey="Kwok K" first="Ka-Wai" last="Kwok">Ka-Wai Kwok</name>
</author>
<author>
<name sortKey="Yang, Guang Zhong" sort="Yang, Guang Zhong" uniqKey="Yang G" first="Guang-Zhong" last="Yang">Guang-Zhong Yang</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">24744963</idno>
<idno type="pmc">3987169</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3987169</idno>
<idno type="RBID">PMC:3987169</idno>
<idno type="doi">10.1109/IROS.2013.6696717</idno>
<date when="2013">2013</date>
<idno type="wicri:Area/Pmc/Corpus">001849</idno>
<idno type="wicri:Area/Pmc/Curation">001849</idno>
<idno type="wicri:Area/Pmc/Checkpoint">001413</idno>
<idno type="wicri:Area/Ncbi/Merge">002F00</idno>
<idno type="wicri:Area/Ncbi/Curation">002F00</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">002F00</idno>
<idno type="wicri:doubleKey">2153-0858:2013:Payne C:an:ungrounded:hand</idno>
<idno type="wicri:Area/Main/Merge">001D92</idno>
<idno type="wicri:Area/Main/Curation">001D70</idno>
<idno type="wicri:Area/Main/Exploration">001D70</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">An Ungrounded Hand-Held Surgical Device Incorporating Active Constraints with Force-Feedback</title>
<author>
<name sortKey="Payne, Christopher J" sort="Payne, Christopher J" uniqKey="Payne C" first="Christopher J." last="Payne">Christopher J. Payne</name>
</author>
<author>
<name sortKey="Kwok, Ka Wai" sort="Kwok, Ka Wai" uniqKey="Kwok K" first="Ka-Wai" last="Kwok">Ka-Wai Kwok</name>
</author>
<author>
<name sortKey="Yang, Guang Zhong" sort="Yang, Guang Zhong" uniqKey="Yang G" first="Guang-Zhong" last="Yang">Guang-Zhong Yang</name>
</author>
</analytic>
<series>
<title level="j">Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems</title>
<idno type="ISSN">2153-0858</idno>
<idno type="eISSN">2153-0866</idno>
<imprint>
<date when="2013">2013</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p id="P1">This paper presents an ungrounded, hand-held surgical device that incorporates active constraints and force-feedback. Optical tracking of the device and embedded actuation allow for real-time motion compensation of a surgical tool as an active constraint is encountered. The active constraints can be made soft, so that the surgical tool tip motion is scaled, or rigid, so as to altogether prevent the penetration of the active constraint. Force-feedback is also provided to the operator so as to indicate penetration of the active constraint boundary by the surgical tool. The device has been evaluated in detailed bench tests to quantify its motion scaling and force-feedback capabilities. The combined effects of force-feedback and motion compensation are demonstrated during palpation of an active constraint with rigid and soft boundaries. A user study evaluated the combined effect of motion compensation and force-feedback in preventing penetration of a rigid active constraint. The results have shown the potential of the device operating in an ungrounded setup that incorporates active constraints with force-feedback.</p>
</div>
</front>
</TEI>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Kwok, Ka Wai" sort="Kwok, Ka Wai" uniqKey="Kwok K" first="Ka-Wai" last="Kwok">Ka-Wai Kwok</name>
<name sortKey="Payne, Christopher J" sort="Payne, Christopher J" uniqKey="Payne C" first="Christopher J." last="Payne">Christopher J. Payne</name>
<name sortKey="Yang, Guang Zhong" sort="Yang, Guang Zhong" uniqKey="Yang G" first="Guang-Zhong" last="Yang">Guang-Zhong Yang</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001D70 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 001D70 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     PMC:3987169
   |texte=   An Ungrounded Hand-Held Surgical Device Incorporating Active Constraints with Force-Feedback
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:24744963" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024