Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

A new small-incision technique for injector implantation of transsclerally sutured foldable lenses.

Identifieur interne : 00A713 ( Main/Exploration ); précédent : 00A712; suivant : 00A714

A new small-incision technique for injector implantation of transsclerally sutured foldable lenses.

Auteurs : Peter Szurman [Allemagne] ; Katrin Petermeier ; Gesine B. Jaissle ; Karl U. Bartz-Schmidt

Source :

RBID : pubmed:17278543

English descriptors

Abstract

A new, minimally invasive technique for clear cornea implantation of one-piece acrylic posterior chamber lenses for transscleral suture fixation in aphakic eyes without capsular support is described. Based on the techniques of modern small-incision cataract surgery, implantation was performed through a self-sealing, 2.75-mm temporal clear cornea incision using the injector technique. This was possible by modifying the insertion of the lens into the cartridge and introducing a new suturing technique of the lens. Suturing of the leading haptic end was performed while the lens was still securely stored inside the cartridge. The trailing haptic was tied after implantation. By using a self-sealing tunnel incision and injector technique, significant fluid egress and consecutive transient hypotony may be minimized throughout the procedure and early visual rehabilitation achieved.

PubMed: 17278543


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">A new small-incision technique for injector implantation of transsclerally sutured foldable lenses.</title>
<author>
<name sortKey="Szurman, Peter" sort="Szurman, Peter" uniqKey="Szurman P" first="Peter" last="Szurman">Peter Szurman</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Ophthalmology I, University of Tubingen, Tubingen, Germany.</nlm:affiliation>
<country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Department of Ophthalmology I, University of Tubingen, Tubingen</wicri:regionArea>
<wicri:noRegion>Tubingen</wicri:noRegion>
<wicri:noRegion>Tubingen</wicri:noRegion>
<wicri:noRegion>Tubingen</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Petermeier, Katrin" sort="Petermeier, Katrin" uniqKey="Petermeier K" first="Katrin" last="Petermeier">Katrin Petermeier</name>
</author>
<author>
<name sortKey="Jaissle, Gesine B" sort="Jaissle, Gesine B" uniqKey="Jaissle G" first="Gesine B" last="Jaissle">Gesine B. Jaissle</name>
</author>
<author>
<name sortKey="Bartz Schmidt, Karl U" sort="Bartz Schmidt, Karl U" uniqKey="Bartz Schmidt K" first="Karl U" last="Bartz-Schmidt">Karl U. Bartz-Schmidt</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="????">
<PubDate>
<MedlineDate>2007 Jan-Feb</MedlineDate>
</PubDate>
</date>
<idno type="RBID">pubmed:17278543</idno>
<idno type="pmid">17278543</idno>
<idno type="wicri:Area/PubMed/Corpus">001695</idno>
<idno type="wicri:Area/PubMed/Curation">001695</idno>
<idno type="wicri:Area/PubMed/Checkpoint">002462</idno>
<idno type="wicri:Area/Ncbi/Merge">000A73</idno>
<idno type="wicri:Area/Ncbi/Curation">000A73</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000A73</idno>
<idno type="wicri:doubleKey">1542-8877::Szurman P:a:new:small</idno>
<idno type="wicri:Area/Main/Merge">00B258</idno>
<idno type="wicri:Area/Main/Curation">00A713</idno>
<idno type="wicri:Area/Main/Exploration">00A713</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">A new small-incision technique for injector implantation of transsclerally sutured foldable lenses.</title>
<author>
<name sortKey="Szurman, Peter" sort="Szurman, Peter" uniqKey="Szurman P" first="Peter" last="Szurman">Peter Szurman</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Ophthalmology I, University of Tubingen, Tubingen, Germany.</nlm:affiliation>
<country xml:lang="fr">Allemagne</country>
<wicri:regionArea>Department of Ophthalmology I, University of Tubingen, Tubingen</wicri:regionArea>
<wicri:noRegion>Tubingen</wicri:noRegion>
<wicri:noRegion>Tubingen</wicri:noRegion>
<wicri:noRegion>Tubingen</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Petermeier, Katrin" sort="Petermeier, Katrin" uniqKey="Petermeier K" first="Katrin" last="Petermeier">Katrin Petermeier</name>
</author>
<author>
<name sortKey="Jaissle, Gesine B" sort="Jaissle, Gesine B" uniqKey="Jaissle G" first="Gesine B" last="Jaissle">Gesine B. Jaissle</name>
</author>
<author>
<name sortKey="Bartz Schmidt, Karl U" sort="Bartz Schmidt, Karl U" uniqKey="Bartz Schmidt K" first="Karl U" last="Bartz-Schmidt">Karl U. Bartz-Schmidt</name>
</author>
</analytic>
<series>
<title level="j">Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye</title>
<idno type="ISSN">1542-8877</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aphakia, Postcataract (surgery)</term>
<term>Equipment Design</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Lens Implantation, Intraocular (instrumentation)</term>
<term>Lenses, Intraocular</term>
<term>Minimally Invasive Surgical Procedures (methods)</term>
<term>Sclera (surgery)</term>
<term>Suture Techniques (instrumentation)</term>
<term>Treatment Outcome</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" qualifier="instrumentation" xml:lang="en">
<term>Lens Implantation, Intraocular</term>
<term>Suture Techniques</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Minimally Invasive Surgical Procedures</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Aphakia, Postcataract</term>
<term>Sclera</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Equipment Design</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Treatment Outcome</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">A new, minimally invasive technique for clear cornea implantation of one-piece acrylic posterior chamber lenses for transscleral suture fixation in aphakic eyes without capsular support is described. Based on the techniques of modern small-incision cataract surgery, implantation was performed through a self-sealing, 2.75-mm temporal clear cornea incision using the injector technique. This was possible by modifying the insertion of the lens into the cartridge and introducing a new suturing technique of the lens. Suturing of the leading haptic end was performed while the lens was still securely stored inside the cartridge. The trailing haptic was tied after implantation. By using a self-sealing tunnel incision and injector technique, significant fluid egress and consecutive transient hypotony may be minimized throughout the procedure and early visual rehabilitation achieved.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Allemagne</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Bartz Schmidt, Karl U" sort="Bartz Schmidt, Karl U" uniqKey="Bartz Schmidt K" first="Karl U" last="Bartz-Schmidt">Karl U. Bartz-Schmidt</name>
<name sortKey="Jaissle, Gesine B" sort="Jaissle, Gesine B" uniqKey="Jaissle G" first="Gesine B" last="Jaissle">Gesine B. Jaissle</name>
<name sortKey="Petermeier, Katrin" sort="Petermeier, Katrin" uniqKey="Petermeier K" first="Katrin" last="Petermeier">Katrin Petermeier</name>
</noCountry>
<country name="Allemagne">
<noRegion>
<name sortKey="Szurman, Peter" sort="Szurman, Peter" uniqKey="Szurman P" first="Peter" last="Szurman">Peter Szurman</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 00A713 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 00A713 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:17278543
   |texte=   A new small-incision technique for injector implantation of transsclerally sutured foldable lenses.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:17278543" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024