Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

The assessment of stability and reliability of a virtual reality-based intravenous injection simulator.

Identifieur interne : 00A487 ( Main/Exploration ); précédent : 00A486; suivant : 00A488

The assessment of stability and reliability of a virtual reality-based intravenous injection simulator.

Auteurs : Wen-Wei Tsai [Taïwan] ; Chin-Ping Fung ; Sing-Ling Tsai ; Ming-Chang Jeng ; Ji-Liang Doong

Source :

RBID : pubmed:18600130

English descriptors

Abstract

The aim of this study was to validate the feasibility of a virtual reality-based (without haptic feedback) intravenous injection system as an effective tool for computer-assisted instruction and training. The stability and reliability of the system were assessed. A personal computer, a needle/catheter device, and a data acquisition interface are included in this system. Using Virtual Reality Modeling Language, an interactive virtual environment was developed. Ten participants, ranging from 20 to 28 years of age, were recruited for this study. The self-learning and training procedures encompassed an intravenous catheterization process. The experimental results showed that after a few trials, the change in task time was not obvious in each trial, and the error frequency decreased slightly with more trials. High intraclass correlation coefficients also were obtained for task time and error frequency by analyzing the test-retest reliability. These results indicated that the system was stable and that the system reliability was acceptable.

DOI: 10.1097/01.NCN.0000304804.46369.5a
PubMed: 18600130


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">The assessment of stability and reliability of a virtual reality-based intravenous injection simulator.</title>
<author>
<name sortKey="Tsai, Wen Wei" sort="Tsai, Wen Wei" uniqKey="Tsai W" first="Wen-Wei" last="Tsai">Wen-Wei Tsai</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Mechanical Engineering, National Central University, Chung-Li, Taiwan.</nlm:affiliation>
<country xml:lang="fr">Taïwan</country>
<wicri:regionArea>Department of Mechanical Engineering, National Central University, Chung-Li</wicri:regionArea>
<wicri:noRegion>Chung-Li</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Fung, Chin Ping" sort="Fung, Chin Ping" uniqKey="Fung C" first="Chin-Ping" last="Fung">Chin-Ping Fung</name>
</author>
<author>
<name sortKey="Tsai, Sing Ling" sort="Tsai, Sing Ling" uniqKey="Tsai S" first="Sing-Ling" last="Tsai">Sing-Ling Tsai</name>
</author>
<author>
<name sortKey="Jeng, Ming Chang" sort="Jeng, Ming Chang" uniqKey="Jeng M" first="Ming-Chang" last="Jeng">Ming-Chang Jeng</name>
</author>
<author>
<name sortKey="Doong, Ji Liang" sort="Doong, Ji Liang" uniqKey="Doong J" first="Ji-Liang" last="Doong">Ji-Liang Doong</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="????">
<PubDate>
<MedlineDate>2008 Jul-Aug</MedlineDate>
</PubDate>
</date>
<idno type="doi">10.1097/01.NCN.0000304804.46369.5a</idno>
<idno type="RBID">pubmed:18600130</idno>
<idno type="pmid">18600130</idno>
<idno type="wicri:Area/PubMed/Corpus">001423</idno>
<idno type="wicri:Area/PubMed/Curation">001423</idno>
<idno type="wicri:Area/PubMed/Checkpoint">002238</idno>
<idno type="wicri:Area/Ncbi/Merge">000E76</idno>
<idno type="wicri:Area/Ncbi/Curation">000E76</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000E76</idno>
<idno type="wicri:Area/Main/Merge">00B032</idno>
<idno type="wicri:Area/Main/Curation">00A487</idno>
<idno type="wicri:Area/Main/Exploration">00A487</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">The assessment of stability and reliability of a virtual reality-based intravenous injection simulator.</title>
<author>
<name sortKey="Tsai, Wen Wei" sort="Tsai, Wen Wei" uniqKey="Tsai W" first="Wen-Wei" last="Tsai">Wen-Wei Tsai</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Mechanical Engineering, National Central University, Chung-Li, Taiwan.</nlm:affiliation>
<country xml:lang="fr">Taïwan</country>
<wicri:regionArea>Department of Mechanical Engineering, National Central University, Chung-Li</wicri:regionArea>
<wicri:noRegion>Chung-Li</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Fung, Chin Ping" sort="Fung, Chin Ping" uniqKey="Fung C" first="Chin-Ping" last="Fung">Chin-Ping Fung</name>
</author>
<author>
<name sortKey="Tsai, Sing Ling" sort="Tsai, Sing Ling" uniqKey="Tsai S" first="Sing-Ling" last="Tsai">Sing-Ling Tsai</name>
</author>
<author>
<name sortKey="Jeng, Ming Chang" sort="Jeng, Ming Chang" uniqKey="Jeng M" first="Ming-Chang" last="Jeng">Ming-Chang Jeng</name>
</author>
<author>
<name sortKey="Doong, Ji Liang" sort="Doong, Ji Liang" uniqKey="Doong J" first="Ji-Liang" last="Doong">Ji-Liang Doong</name>
</author>
</analytic>
<series>
<title level="j">Computers, informatics, nursing : CIN</title>
<idno type="eISSN">1538-9774</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult</term>
<term>Computer-Assisted Instruction</term>
<term>Feasibility Studies</term>
<term>Humans</term>
<term>Injections, Intravenous</term>
<term>Reproducibility of Results</term>
<term>User-Computer Interface</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Computer-Assisted Instruction</term>
<term>Feasibility Studies</term>
<term>Humans</term>
<term>Injections, Intravenous</term>
<term>Reproducibility of Results</term>
<term>User-Computer Interface</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The aim of this study was to validate the feasibility of a virtual reality-based (without haptic feedback) intravenous injection system as an effective tool for computer-assisted instruction and training. The stability and reliability of the system were assessed. A personal computer, a needle/catheter device, and a data acquisition interface are included in this system. Using Virtual Reality Modeling Language, an interactive virtual environment was developed. Ten participants, ranging from 20 to 28 years of age, were recruited for this study. The self-learning and training procedures encompassed an intravenous catheterization process. The experimental results showed that after a few trials, the change in task time was not obvious in each trial, and the error frequency decreased slightly with more trials. High intraclass correlation coefficients also were obtained for task time and error frequency by analyzing the test-retest reliability. These results indicated that the system was stable and that the system reliability was acceptable.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Taïwan</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Doong, Ji Liang" sort="Doong, Ji Liang" uniqKey="Doong J" first="Ji-Liang" last="Doong">Ji-Liang Doong</name>
<name sortKey="Fung, Chin Ping" sort="Fung, Chin Ping" uniqKey="Fung C" first="Chin-Ping" last="Fung">Chin-Ping Fung</name>
<name sortKey="Jeng, Ming Chang" sort="Jeng, Ming Chang" uniqKey="Jeng M" first="Ming-Chang" last="Jeng">Ming-Chang Jeng</name>
<name sortKey="Tsai, Sing Ling" sort="Tsai, Sing Ling" uniqKey="Tsai S" first="Sing-Ling" last="Tsai">Sing-Ling Tsai</name>
</noCountry>
<country name="Taïwan">
<noRegion>
<name sortKey="Tsai, Wen Wei" sort="Tsai, Wen Wei" uniqKey="Tsai W" first="Wen-Wei" last="Tsai">Wen-Wei Tsai</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 00A487 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 00A487 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:18600130
   |texte=   The assessment of stability and reliability of a virtual reality-based intravenous injection simulator.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:18600130" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024