Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Side-view analysis of the lens. II. Positioning of intraocular lenses.

Identifieur interne : 009499 ( Main/Exploration ); précédent : 009498; suivant : 009500

Side-view analysis of the lens. II. Positioning of intraocular lenses.

Auteurs : E I Assia ; D J Apple

Source :

RBID : pubmed:1731730

English descriptors

Abstract

The uveoscleral window technique is useful for studying the position and fixation of posterior chamber intraocular lenses (IOLs). Studies using this technique show that the configuration of an IOL in the capsular bag largely depends on three factors: size, shape, and relative rigidity of the IOL. The general configuration of the capsular bag is that of a flattened saucer created by radial expansion of the haptic. Zonules at the fixation site are relaxed, eliminating the possibility of accommodation with thin IOLs. Downsized IOLs (total diameter of 12.0 mm) provide stable fixation with less tension on the capsule than larger IOLs.

PubMed: 1731730


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Side-view analysis of the lens. II. Positioning of intraocular lenses.</title>
<author>
<name sortKey="Assia, E I" sort="Assia, E I" uniqKey="Assia E" first="E I" last="Assia">E I Assia</name>
<affiliation>
<nlm:affiliation>Department of Ophthalmology, Storm Eye Institute, Medical University of South Carolina, Charleston 29425.</nlm:affiliation>
<wicri:noCountry code="subField">Charleston 29425</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Apple, D J" sort="Apple, D J" uniqKey="Apple D" first="D J" last="Apple">D J Apple</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1992">1992</date>
<idno type="RBID">pubmed:1731730</idno>
<idno type="pmid">1731730</idno>
<idno type="wicri:Area/PubMed/Corpus">002201</idno>
<idno type="wicri:Area/PubMed/Curation">002201</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001F11</idno>
<idno type="wicri:Area/Ncbi/Merge">000A86</idno>
<idno type="wicri:Area/Ncbi/Curation">000A86</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000A86</idno>
<idno type="wicri:doubleKey">0003-9950:1992:Assia E:side:view:analysis</idno>
<idno type="wicri:Area/Main/Merge">009F04</idno>
<idno type="wicri:Area/Main/Curation">009499</idno>
<idno type="wicri:Area/Main/Exploration">009499</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Side-view analysis of the lens. II. Positioning of intraocular lenses.</title>
<author>
<name sortKey="Assia, E I" sort="Assia, E I" uniqKey="Assia E" first="E I" last="Assia">E I Assia</name>
<affiliation>
<nlm:affiliation>Department of Ophthalmology, Storm Eye Institute, Medical University of South Carolina, Charleston 29425.</nlm:affiliation>
<wicri:noCountry code="subField">Charleston 29425</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Apple, D J" sort="Apple, D J" uniqKey="Apple D" first="D J" last="Apple">D J Apple</name>
</author>
</analytic>
<series>
<title level="j">Archives of ophthalmology (Chicago, Ill. : 1960)</title>
<idno type="ISSN">0003-9950</idno>
<imprint>
<date when="1992" type="published">1992</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Cataract Extraction</term>
<term>Humans</term>
<term>Lens Capsule, Crystalline (anatomy & histology)</term>
<term>Lens Capsule, Crystalline (pathology)</term>
<term>Lens, Crystalline (anatomy & histology)</term>
<term>Lens, Crystalline (pathology)</term>
<term>Lenses, Intraocular</term>
</keywords>
<keywords scheme="MESH" qualifier="anatomy & histology" xml:lang="en">
<term>Lens Capsule, Crystalline</term>
<term>Lens, Crystalline</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Lens Capsule, Crystalline</term>
<term>Lens, Crystalline</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Cataract Extraction</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The uveoscleral window technique is useful for studying the position and fixation of posterior chamber intraocular lenses (IOLs). Studies using this technique show that the configuration of an IOL in the capsular bag largely depends on three factors: size, shape, and relative rigidity of the IOL. The general configuration of the capsular bag is that of a flattened saucer created by radial expansion of the haptic. Zonules at the fixation site are relaxed, eliminating the possibility of accommodation with thin IOLs. Downsized IOLs (total diameter of 12.0 mm) provide stable fixation with less tension on the capsule than larger IOLs.</div>
</front>
</TEI>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Apple, D J" sort="Apple, D J" uniqKey="Apple D" first="D J" last="Apple">D J Apple</name>
<name sortKey="Assia, E I" sort="Assia, E I" uniqKey="Assia E" first="E I" last="Assia">E I Assia</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 009499 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 009499 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:1731730
   |texte=   Side-view analysis of the lens. II. Positioning of intraocular lenses.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:1731730" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024