Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Compression forces of haptics of selected posterior chamber lenses

Identifieur interne : 008B32 ( Main/Exploration ); précédent : 008B31; suivant : 008B33

Compression forces of haptics of selected posterior chamber lenses

Auteurs : Olavi P Rssinen [Finlande] ; Jorma R Ty [Finlande] ; Anneli Klemetti ; Anna-Liisa Lyyra [Finlande] ; Jussi Timonen [Finlande]

Source :

RBID : ISTEX:713AA36BA203595E1C89770165267A1F4630713E

Descripteurs français

English descriptors

Abstract

Purpose: To compare the compressive forces of the haptics of different intraocular lens (IOL) models and analyze the observed differences.Setting: Central Hospital of Central Finland and University of Jyväskylä, Jyväskylä, Finland.Methods: The haptics of 28 IOL models were compressed to a diameter of 9.0 mm. The compression forces were measured at 0.5 mm intervals. The conclusions were verified by numerical simulations of mechanical models of the lenses.Results: The measured forces varied between 100 and 601 mg at a diameter of 11.0 mm, 206 and 1057 mg at a diameter of 10.0 mm, and 315 and 2094 mg at a diameter of 9.0 mm. The slopes of the force curves of the three-piece lenses were fairly linear. In general, the three-piece models were less rigid than one-piece models and underwent plastic deformations after repeated compressions. For most one-piece models, compression force increased progressively with increasing compression. The overall IOL diameter and differences in haptic thickness and length and the angle between optic at the point of haptic insertion were the main causes of the observed differences in the compression forces. The variation in forces between individual specimens of the same model, which occurred with almost all models, were mainly the result of variations in haptic thickness.Conclusion: Great variations in the compression forces of the IOL haptics were found. Compression behaviors should be taken into account when selecting a lens to implant.

Url:
DOI: 10.1016/S0886-3350(97)80322-7


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Compression forces of haptics of selected posterior chamber lenses</title>
<author>
<name sortKey="P Rssinen, Olavi" sort="P Rssinen, Olavi" uniqKey="P Rssinen O" first="Olavi" last="P Rssinen">Olavi P Rssinen</name>
</author>
<author>
<name sortKey="R Ty, Jorma" sort="R Ty, Jorma" uniqKey="R Ty J" first="Jorma" last="R Ty">Jorma R Ty</name>
</author>
<author>
<name sortKey="Klemetti, Anneli" sort="Klemetti, Anneli" uniqKey="Klemetti A" first="Anneli" last="Klemetti">Anneli Klemetti</name>
</author>
<author>
<name sortKey="Lyyra, Anna Liisa" sort="Lyyra, Anna Liisa" uniqKey="Lyyra A" first="Anna-Liisa" last="Lyyra">Anna-Liisa Lyyra</name>
</author>
<author>
<name sortKey="Timonen, Jussi" sort="Timonen, Jussi" uniqKey="Timonen J" first="Jussi" last="Timonen">Jussi Timonen</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:713AA36BA203595E1C89770165267A1F4630713E</idno>
<date when="1997" year="1997">1997</date>
<idno type="doi">10.1016/S0886-3350(97)80322-7</idno>
<idno type="url">https://api.istex.fr/document/713AA36BA203595E1C89770165267A1F4630713E/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">002255</idno>
<idno type="wicri:Area/Istex/Curation">002255</idno>
<idno type="wicri:Area/Istex/Checkpoint">003C60</idno>
<idno type="wicri:doubleKey">0886-3350:1997:P Rssinen O:compression:forces:of</idno>
<idno type="wicri:Area/Main/Merge">009411</idno>
<idno type="wicri:source">INIST</idno>
<idno type="RBID">Pascal:98-0017344</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">001643</idno>
<idno type="wicri:Area/PascalFrancis/Curation">001477</idno>
<idno type="wicri:Area/PascalFrancis/Checkpoint">001435</idno>
<idno type="wicri:doubleKey">0886-3350:1997:P Rssinen O:compression:forces:of</idno>
<idno type="wicri:Area/Main/Merge">009517</idno>
<idno type="wicri:source">PubMed</idno>
<idno type="RBID">pubmed:9368171</idno>
<idno type="wicri:Area/PubMed/Corpus">002007</idno>
<idno type="wicri:Area/PubMed/Curation">002007</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001D73</idno>
<idno type="wicri:Area/Ncbi/Merge">004664</idno>
<idno type="wicri:Area/Ncbi/Curation">004664</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">004664</idno>
<idno type="wicri:doubleKey">0886-3350:1997:P Rssinen O:compression:forces:of</idno>
<idno type="wicri:Area/Main/Merge">009160</idno>
<idno type="wicri:Area/Main/Curation">008B32</idno>
<idno type="wicri:Area/Main/Exploration">008B32</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Compression forces of haptics of selected posterior chamber lenses</title>
<author>
<name sortKey="P Rssinen, Olavi" sort="P Rssinen, Olavi" uniqKey="P Rssinen O" first="Olavi" last="P Rssinen">Olavi P Rssinen</name>
<affiliation>
<wicri:noCountry code="subField">Central Hospital of Central Finland</wicri:noCountry>
</affiliation>
<affiliation wicri:level="1">
<country xml:lang="fr">Finlande</country>
<wicri:regionArea>Reprint requests to Olavi Pärssinen, MD, PhD, Kannaksenkatu 5 40600 Jyväskylä</wicri:regionArea>
<wicri:noRegion>Kannaksenkatu 5 40600 Jyväskylä</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="R Ty, Jorma" sort="R Ty, Jorma" uniqKey="R Ty J" first="Jorma" last="R Ty">Jorma R Ty</name>
<affiliation wicri:level="4">
<country xml:lang="fr">Finlande</country>
<wicri:regionArea>Department of Physics, University of Jyväskylä, Jyväskylä</wicri:regionArea>
<orgName type="university">Université de Jyväskylä</orgName>
<placeName>
<settlement type="city">Jyväskylä</settlement>
<region type="région" nuts="2">Finlande-Centrale</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Klemetti, Anneli" sort="Klemetti, Anneli" uniqKey="Klemetti A" first="Anneli" last="Klemetti">Anneli Klemetti</name>
<affiliation>
<wicri:noCountry code="subField">Central Hospital of Central Finland</wicri:noCountry>
</affiliation>
</author>
<author>
<name sortKey="Lyyra, Anna Liisa" sort="Lyyra, Anna Liisa" uniqKey="Lyyra A" first="Anna-Liisa" last="Lyyra">Anna-Liisa Lyyra</name>
<affiliation wicri:level="4">
<country xml:lang="fr">Finlande</country>
<wicri:regionArea>Department of Statistics, University of Jyväskylä, Jyväskylä</wicri:regionArea>
<orgName type="university">Université de Jyväskylä</orgName>
<placeName>
<settlement type="city">Jyväskylä</settlement>
<region type="région" nuts="2">Finlande-Centrale</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Timonen, Jussi" sort="Timonen, Jussi" uniqKey="Timonen J" first="Jussi" last="Timonen">Jussi Timonen</name>
<affiliation wicri:level="4">
<country xml:lang="fr">Finlande</country>
<wicri:regionArea>Department of Physics, University of Jyväskylä, Jyväskylä</wicri:regionArea>
<orgName type="university">Université de Jyväskylä</orgName>
<placeName>
<settlement type="city">Jyväskylä</settlement>
<region type="région" nuts="2">Finlande-Centrale</region>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Journal of Cataract & Refractive Surgery</title>
<title level="j" type="abbrev">JCRS</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<publisher>ELSEVIER</publisher>
<date type="published" when="1997">1997</date>
<biblScope unit="volume">23</biblScope>
<biblScope unit="issue">8</biblScope>
<biblScope unit="page" from="1237">1237</biblScope>
<biblScope unit="page" to="1246">1246</biblScope>
</imprint>
<idno type="ISSN">0886-3350</idno>
</series>
<idno type="istex">713AA36BA203595E1C89770165267A1F4630713E</idno>
<idno type="DOI">10.1016/S0886-3350(97)80322-7</idno>
<idno type="PII">S0886-3350(97)80322-7</idno>
<idno type="ArticleID">80322</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0886-3350</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Cataract</term>
<term>Comparative study</term>
<term>Compression</term>
<term>Compressive Strength</term>
<term>Force</term>
<term>Implantation</term>
<term>Intraocular lens</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
<term>Posterior chamber</term>
<term>Simulation model</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Compressive Strength</term>
<term>Lens Implantation, Intraocular</term>
<term>Lenses, Intraocular</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Cataracte</term>
<term>Chambre postérieure</term>
<term>Compression</term>
<term>Etude comparative</term>
<term>Force</term>
<term>Haptique</term>
<term>Implantation</term>
<term>Lentille intraoculaire</term>
<term>Modèle simulation</term>
</keywords>
</textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Purpose: To compare the compressive forces of the haptics of different intraocular lens (IOL) models and analyze the observed differences.Setting: Central Hospital of Central Finland and University of Jyväskylä, Jyväskylä, Finland.Methods: The haptics of 28 IOL models were compressed to a diameter of 9.0 mm. The compression forces were measured at 0.5 mm intervals. The conclusions were verified by numerical simulations of mechanical models of the lenses.Results: The measured forces varied between 100 and 601 mg at a diameter of 11.0 mm, 206 and 1057 mg at a diameter of 10.0 mm, and 315 and 2094 mg at a diameter of 9.0 mm. The slopes of the force curves of the three-piece lenses were fairly linear. In general, the three-piece models were less rigid than one-piece models and underwent plastic deformations after repeated compressions. For most one-piece models, compression force increased progressively with increasing compression. The overall IOL diameter and differences in haptic thickness and length and the angle between optic at the point of haptic insertion were the main causes of the observed differences in the compression forces. The variation in forces between individual specimens of the same model, which occurred with almost all models, were mainly the result of variations in haptic thickness.Conclusion: Great variations in the compression forces of the IOL haptics were found. Compression behaviors should be taken into account when selecting a lens to implant.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Finlande</li>
</country>
<region>
<li>Finlande-Centrale</li>
</region>
<settlement>
<li>Jyväskylä</li>
</settlement>
<orgName>
<li>Université de Jyväskylä</li>
</orgName>
</list>
<tree>
<noCountry>
<name sortKey="Klemetti, Anneli" sort="Klemetti, Anneli" uniqKey="Klemetti A" first="Anneli" last="Klemetti">Anneli Klemetti</name>
</noCountry>
<country name="Finlande">
<noRegion>
<name sortKey="P Rssinen, Olavi" sort="P Rssinen, Olavi" uniqKey="P Rssinen O" first="Olavi" last="P Rssinen">Olavi P Rssinen</name>
</noRegion>
<name sortKey="Lyyra, Anna Liisa" sort="Lyyra, Anna Liisa" uniqKey="Lyyra A" first="Anna-Liisa" last="Lyyra">Anna-Liisa Lyyra</name>
<name sortKey="R Ty, Jorma" sort="R Ty, Jorma" uniqKey="R Ty J" first="Jorma" last="R Ty">Jorma R Ty</name>
<name sortKey="Timonen, Jussi" sort="Timonen, Jussi" uniqKey="Timonen J" first="Jussi" last="Timonen">Jussi Timonen</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 008B32 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 008B32 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:713AA36BA203595E1C89770165267A1F4630713E
   |texte=   Compression forces of haptics of selected posterior chamber lenses
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024