Intraocular lens factors that may affect anterior capsule contraction

Identifieur interne : 006578 ( Main/Exploration ); précédent : 006577; suivant : 006579

Intraocular lens factors that may affect anterior capsule contraction

Auteurs : Ken Hayashi [Japon] ; Hideyuki Hayashi [Japon]

Source :

RBID : Pascal:05-0154703

Descripteurs français

English descriptors

Abstract

Purpose: To examine the various factors comprising intraocular lenses (lOLs) that may affect the degree of anterior capsule contraction after cataract surgery. Design: Randomized controlled clinical trials. Participants: Three hundred thirty-one patients scheduled for bilateral cataract surgery were studied to compare the degree of anterior capsule contraction in fellow eyes that received different lOLs with regard to the following factors: (1) optic material-acrylic optic versus silicone optic; (2) optic design-round-edge optic versus sharp-edge optic; (3) haptic material-polymethyl methacrylate (PMMA) loop versus polyvinylidene fluoride loop; and (4) haptic material and design-single-piece acrylic haptic versus 3-piece PMMA haptic. The 2 lOLs implanted in the fellow eyes of each patient had almost the same material and design, except for the specific factor being compared. Methods: All patients underwent phacoemulsification surgery with implantation of different lOLs in fellow eyes. Main Outcome Measures: The area of the anterior capsule opening was measured using the Scheimpflug videophotography system at 3 days or 1 week (baseline) and at 1, 3, and 6 months after surgery. The percent reduction in the anterior capsule opening area from baseline was determined at 1, 3, and 6 months after surgery. Results: The mean percent reduction of the anterior capsule opening area was significantly greater in eyes with a silicone optic IOL than in eyes with an acrylic optic IOL. However, no significant difference was observed in the percent reduction between round-edge and sharp-edge optic lOLs, between PMMA and polyvinylidene fluoride loop lOLs, and between single-piece acrylic and 3-piece PMMA haptic lOLs. Strong associations were found in the percentage between round-edge and sharp-edge optic lOLs, between PMMA and polyvinylidene fluoride loop lOLs, and between single-piece acrylic and 3-piece PMMA haptic lOLs, whereas there was a relatively weak association between silicone and acrylic optic lOLs. Conclusions: Among the IOL factors examined, optic material affects most significantly the degree of anterior capsule contraction, whereas optic design and haptic material and design are not strongly related to anterior capsule contraction.


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en" level="a">Intraocular lens factors that may affect anterior capsule contraction</title>
<author>
<name sortKey="Hayashi, Ken" sort="Hayashi, Ken" uniqKey="Hayashi K" first="Ken" last="Hayashi">Ken Hayashi</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>Hayashi Eye Hospital</s1>
<s2>Fukuoka</s2>
<s3>JPN</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
<country>Japon</country>
<wicri:noRegion>Hayashi Eye Hospital</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Hayashi, Hideyuki" sort="Hayashi, Hideyuki" uniqKey="Hayashi H" first="Hideyuki" last="Hayashi">Hideyuki Hayashi</name>
<affiliation wicri:level="1">
<inist:fA14 i1="02">
<s1>Department of Ophthalmology, School of Medicine, Fukuoka University</s1>
<s2>Fukuoka</s2>
<s3>JPN</s3>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>Japon</country>
<wicri:noRegion>Fukuoka</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">INIST</idno>
<idno type="inist">05-0154703</idno>
<date when="2005">2005</date>
<idno type="stanalyst">PASCAL 05-0154703 INIST</idno>
<idno type="RBID">Pascal:05-0154703</idno>
<idno type="wicri:Area/PascalFrancis/Corpus">000E96</idno>
<idno type="wicri:Area/PascalFrancis/Curation">000612</idno>
<idno type="wicri:Area/PascalFrancis/Checkpoint">000B13</idno>
<idno type="wicri:doubleKey">0161-6420:2005:Hayashi K:intraocular:lens:factors</idno>
<idno type="wicri:Area/Main/Merge">006923</idno>
<idno type="wicri:Area/Main/Curation">006578</idno>
<idno type="wicri:Area/Main/Exploration">006578</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a">Intraocular lens factors that may affect anterior capsule contraction</title>
<author>
<name sortKey="Hayashi, Ken" sort="Hayashi, Ken" uniqKey="Hayashi K" first="Ken" last="Hayashi">Ken Hayashi</name>
<affiliation wicri:level="1">
<inist:fA14 i1="01">
<s1>Hayashi Eye Hospital</s1>
<s2>Fukuoka</s2>
<s3>JPN</s3>
<sZ>1 aut.</sZ>
</inist:fA14>
<country>Japon</country>
<wicri:noRegion>Hayashi Eye Hospital</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Hayashi, Hideyuki" sort="Hayashi, Hideyuki" uniqKey="Hayashi H" first="Hideyuki" last="Hayashi">Hideyuki Hayashi</name>
<affiliation wicri:level="1">
<inist:fA14 i1="02">
<s1>Department of Ophthalmology, School of Medicine, Fukuoka University</s1>
<s2>Fukuoka</s2>
<s3>JPN</s3>
<sZ>2 aut.</sZ>
</inist:fA14>
<country>Japon</country>
<wicri:noRegion>Fukuoka</wicri:noRegion>
</affiliation>
</author>
</analytic>
<series>
<title level="j" type="main">Ophthalmology : (Rochester, MN)</title>
<title level="j" type="abbreviated">Ophthalmology : (Rochester MN)</title>
<idno type="ISSN">0161-6420</idno>
<imprint>
<date when="2005">2005</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<title level="j" type="main">Ophthalmology : (Rochester, MN)</title>
<title level="j" type="abbreviated">Ophthalmology : (Rochester MN)</title>
<idno type="ISSN">0161-6420</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Anterior</term>
<term>Capsule</term>
<term>Complication</term>
<term>Contraction</term>
<term>Human</term>
<term>Intraocular lens</term>
<term>Ophthalmology</term>
<term>Treatment</term>
</keywords>
<keywords scheme="Pascal" xml:lang="fr">
<term>Lentille intraoculaire</term>
<term>Antérieur</term>
<term>Capsule</term>
<term>Complication</term>
<term>Contraction</term>
<term>Ophtalmologie</term>
<term>Homme</term>
<term>Traitement</term>
</keywords>
<keywords scheme="Wicri" type="topic" xml:lang="fr">
<term>Homme</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Purpose: To examine the various factors comprising intraocular lenses (lOLs) that may affect the degree of anterior capsule contraction after cataract surgery. Design: Randomized controlled clinical trials. Participants: Three hundred thirty-one patients scheduled for bilateral cataract surgery were studied to compare the degree of anterior capsule contraction in fellow eyes that received different lOLs with regard to the following factors: (1) optic material-acrylic optic versus silicone optic; (2) optic design-round-edge optic versus sharp-edge optic; (3) haptic material-polymethyl methacrylate (PMMA) loop versus polyvinylidene fluoride loop; and (4) haptic material and design-single-piece acrylic haptic versus 3-piece PMMA haptic. The 2 lOLs implanted in the fellow eyes of each patient had almost the same material and design, except for the specific factor being compared. Methods: All patients underwent phacoemulsification surgery with implantation of different lOLs in fellow eyes. Main Outcome Measures: The area of the anterior capsule opening was measured using the Scheimpflug videophotography system at 3 days or 1 week (baseline) and at 1, 3, and 6 months after surgery. The percent reduction in the anterior capsule opening area from baseline was determined at 1, 3, and 6 months after surgery. Results: The mean percent reduction of the anterior capsule opening area was significantly greater in eyes with a silicone optic IOL than in eyes with an acrylic optic IOL. However, no significant difference was observed in the percent reduction between round-edge and sharp-edge optic lOLs, between PMMA and polyvinylidene fluoride loop lOLs, and between single-piece acrylic and 3-piece PMMA haptic lOLs. Strong associations were found in the percentage between round-edge and sharp-edge optic lOLs, between PMMA and polyvinylidene fluoride loop lOLs, and between single-piece acrylic and 3-piece PMMA haptic lOLs, whereas there was a relatively weak association between silicone and acrylic optic lOLs. Conclusions: Among the IOL factors examined, optic material affects most significantly the degree of anterior capsule contraction, whereas optic design and haptic material and design are not strongly related to anterior capsule contraction.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Japon</li>
</country>
</list>
<tree>
<country name="Japon">
<noRegion>
<name sortKey="Hayashi, Ken" sort="Hayashi, Ken" uniqKey="Hayashi K" first="Ken" last="Hayashi">Ken Hayashi</name>
</noRegion>
<name sortKey="Hayashi, Hideyuki" sort="Hayashi, Hideyuki" uniqKey="Hayashi H" first="Hideyuki" last="Hayashi">Hideyuki Hayashi</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 006578 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 006578 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     Pascal:05-0154703
   |texte=   Intraocular lens factors that may affect anterior capsule contraction
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024