[Capsule contraction as a cause of in-the-bag intraocular lens subluxation and simplified technique of IOL reposition].
Identifieur interne : 006171 ( Main/Exploration ); précédent : 006170; suivant : 006172[Capsule contraction as a cause of in-the-bag intraocular lens subluxation and simplified technique of IOL reposition].
Auteurs : Piotr JurowskiSource :
- Klinika oczna [ 0023-2157 ] ; 2005.
English descriptors
- KwdEn :
- Aged, Cataract Extraction (adverse effects), Contracture, Eye Foreign Bodies (etiology), Eye Foreign Bodies (surgery), Female, Foreign-Body Migration (etiology), Foreign-Body Migration (surgery), Humans, Lens Capsule, Crystalline (pathology), Lens Capsule, Crystalline (surgery), Lens Subluxation (etiology), Lens Subluxation (surgery), Phacoemulsification (adverse effects), Prosthesis Failure, Reoperation, Visual Acuity.
- MESH :
- adverse effects : Cataract Extraction, Phacoemulsification.
- etiology : Eye Foreign Bodies, Foreign-Body Migration, Lens Subluxation.
- pathology : Lens Capsule, Crystalline.
- surgery : Eye Foreign Bodies, Foreign-Body Migration, Lens Capsule, Crystalline, Lens Subluxation.
- Aged, Contracture, Female, Humans, Prosthesis Failure, Reoperation, Visual Acuity.
Abstract
Presentation of the case of the pseudophakic patient in whom 3 months after uncomplicated phacoemulsification severe capsule contraction syndrome, followed by equatorial capsule fibrosis, 240 degree zonular dialysis, and spontaneous in-the-bag intraocular lens subluxation, were observed. Consecutive surgical intervention consisting of simplified transscleral "free haptic" through the capsule fixation and additional plastic of phimotic capsulorrhexis allowed to restore the best corrected visual acuity to 20/25.
PubMed: 16619820
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream PubMed, to step Corpus: 001809
- to stream PubMed, to step Curation: 001809
- to stream PubMed, to step Checkpoint: 001646
- to stream Ncbi, to step Merge: 000910
- to stream Ncbi, to step Curation: 000910
- to stream Ncbi, to step Checkpoint: 000910
- to stream Main, to step Merge: 006460
- to stream Main, to step Curation: 006171
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">[Capsule contraction as a cause of in-the-bag intraocular lens subluxation and simplified technique of IOL reposition].</title>
<author><name sortKey="Jurowski, Piotr" sort="Jurowski, Piotr" uniqKey="Jurowski P" first="Piotr" last="Jurowski">Piotr Jurowski</name>
<affiliation><nlm:affiliation>Z Kliniki Okulistyki i Rehabilitacji Wzrokowej Uniwersytetu Medycznego w Lodzi.</nlm:affiliation>
<wicri:noCountry code="no comma">Z Kliniki Okulistyki i Rehabilitacji Wzrokowej Uniwersytetu Medycznego w Lodzi.</wicri:noCountry>
</affiliation>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PubMed</idno>
<date when="2005">2005</date>
<idno type="RBID">pubmed:16619820</idno>
<idno type="pmid">16619820</idno>
<idno type="wicri:Area/PubMed/Corpus">001809</idno>
<idno type="wicri:Area/PubMed/Curation">001809</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001646</idno>
<idno type="wicri:Area/Ncbi/Merge">000910</idno>
<idno type="wicri:Area/Ncbi/Curation">000910</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000910</idno>
<idno type="wicri:doubleKey">0023-2157:2005:Jurowski P:capsule:contraction:as</idno>
<idno type="wicri:Area/Main/Merge">006460</idno>
<idno type="wicri:Area/Main/Curation">006171</idno>
<idno type="wicri:Area/Main/Exploration">006171</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en">[Capsule contraction as a cause of in-the-bag intraocular lens subluxation and simplified technique of IOL reposition].</title>
<author><name sortKey="Jurowski, Piotr" sort="Jurowski, Piotr" uniqKey="Jurowski P" first="Piotr" last="Jurowski">Piotr Jurowski</name>
<affiliation><nlm:affiliation>Z Kliniki Okulistyki i Rehabilitacji Wzrokowej Uniwersytetu Medycznego w Lodzi.</nlm:affiliation>
<wicri:noCountry code="no comma">Z Kliniki Okulistyki i Rehabilitacji Wzrokowej Uniwersytetu Medycznego w Lodzi.</wicri:noCountry>
</affiliation>
</author>
</analytic>
<series><title level="j">Klinika oczna</title>
<idno type="ISSN">0023-2157</idno>
<imprint><date when="2005" type="published">2005</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Aged</term>
<term>Cataract Extraction (adverse effects)</term>
<term>Contracture</term>
<term>Eye Foreign Bodies (etiology)</term>
<term>Eye Foreign Bodies (surgery)</term>
<term>Female</term>
<term>Foreign-Body Migration (etiology)</term>
<term>Foreign-Body Migration (surgery)</term>
<term>Humans</term>
<term>Lens Capsule, Crystalline (pathology)</term>
<term>Lens Capsule, Crystalline (surgery)</term>
<term>Lens Subluxation (etiology)</term>
<term>Lens Subluxation (surgery)</term>
<term>Phacoemulsification (adverse effects)</term>
<term>Prosthesis Failure</term>
<term>Reoperation</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en"><term>Cataract Extraction</term>
<term>Phacoemulsification</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en"><term>Eye Foreign Bodies</term>
<term>Foreign-Body Migration</term>
<term>Lens Subluxation</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en"><term>Lens Capsule, Crystalline</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en"><term>Eye Foreign Bodies</term>
<term>Foreign-Body Migration</term>
<term>Lens Capsule, Crystalline</term>
<term>Lens Subluxation</term>
</keywords>
<keywords scheme="MESH" xml:lang="en"><term>Aged</term>
<term>Contracture</term>
<term>Female</term>
<term>Humans</term>
<term>Prosthesis Failure</term>
<term>Reoperation</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Presentation of the case of the pseudophakic patient in whom 3 months after uncomplicated phacoemulsification severe capsule contraction syndrome, followed by equatorial capsule fibrosis, 240 degree zonular dialysis, and spontaneous in-the-bag intraocular lens subluxation, were observed. Consecutive surgical intervention consisting of simplified transscleral "free haptic" through the capsule fixation and additional plastic of phimotic capsulorrhexis allowed to restore the best corrected visual acuity to 20/25.</div>
</front>
</TEI>
<affiliations><list></list>
<tree><noCountry><name sortKey="Jurowski, Piotr" sort="Jurowski, Piotr" uniqKey="Jurowski P" first="Piotr" last="Jurowski">Piotr Jurowski</name>
</noCountry>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 006171 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 006171 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Exploration |type= RBID |clé= pubmed:16619820 |texte= [Capsule contraction as a cause of in-the-bag intraocular lens subluxation and simplified technique of IOL reposition]. }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i -Sk "pubmed:16619820" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
![]() | This area was generated with Dilib version V0.6.23. | ![]() |