Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

[Capsule contraction as a cause of in-the-bag intraocular lens subluxation and simplified technique of IOL reposition].

Identifieur interne : 006171 ( Main/Exploration ); précédent : 006170; suivant : 006172

[Capsule contraction as a cause of in-the-bag intraocular lens subluxation and simplified technique of IOL reposition].

Auteurs : Piotr Jurowski

Source :

RBID : pubmed:16619820

English descriptors

Abstract

Presentation of the case of the pseudophakic patient in whom 3 months after uncomplicated phacoemulsification severe capsule contraction syndrome, followed by equatorial capsule fibrosis, 240 degree zonular dialysis, and spontaneous in-the-bag intraocular lens subluxation, were observed. Consecutive surgical intervention consisting of simplified transscleral "free haptic" through the capsule fixation and additional plastic of phimotic capsulorrhexis allowed to restore the best corrected visual acuity to 20/25.

PubMed: 16619820


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">[Capsule contraction as a cause of in-the-bag intraocular lens subluxation and simplified technique of IOL reposition].</title>
<author>
<name sortKey="Jurowski, Piotr" sort="Jurowski, Piotr" uniqKey="Jurowski P" first="Piotr" last="Jurowski">Piotr Jurowski</name>
<affiliation>
<nlm:affiliation>Z Kliniki Okulistyki i Rehabilitacji Wzrokowej Uniwersytetu Medycznego w Lodzi.</nlm:affiliation>
<wicri:noCountry code="no comma">Z Kliniki Okulistyki i Rehabilitacji Wzrokowej Uniwersytetu Medycznego w Lodzi.</wicri:noCountry>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2005">2005</date>
<idno type="RBID">pubmed:16619820</idno>
<idno type="pmid">16619820</idno>
<idno type="wicri:Area/PubMed/Corpus">001809</idno>
<idno type="wicri:Area/PubMed/Curation">001809</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001646</idno>
<idno type="wicri:Area/Ncbi/Merge">000910</idno>
<idno type="wicri:Area/Ncbi/Curation">000910</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000910</idno>
<idno type="wicri:doubleKey">0023-2157:2005:Jurowski P:capsule:contraction:as</idno>
<idno type="wicri:Area/Main/Merge">006460</idno>
<idno type="wicri:Area/Main/Curation">006171</idno>
<idno type="wicri:Area/Main/Exploration">006171</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">[Capsule contraction as a cause of in-the-bag intraocular lens subluxation and simplified technique of IOL reposition].</title>
<author>
<name sortKey="Jurowski, Piotr" sort="Jurowski, Piotr" uniqKey="Jurowski P" first="Piotr" last="Jurowski">Piotr Jurowski</name>
<affiliation>
<nlm:affiliation>Z Kliniki Okulistyki i Rehabilitacji Wzrokowej Uniwersytetu Medycznego w Lodzi.</nlm:affiliation>
<wicri:noCountry code="no comma">Z Kliniki Okulistyki i Rehabilitacji Wzrokowej Uniwersytetu Medycznego w Lodzi.</wicri:noCountry>
</affiliation>
</author>
</analytic>
<series>
<title level="j">Klinika oczna</title>
<idno type="ISSN">0023-2157</idno>
<imprint>
<date when="2005" type="published">2005</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aged</term>
<term>Cataract Extraction (adverse effects)</term>
<term>Contracture</term>
<term>Eye Foreign Bodies (etiology)</term>
<term>Eye Foreign Bodies (surgery)</term>
<term>Female</term>
<term>Foreign-Body Migration (etiology)</term>
<term>Foreign-Body Migration (surgery)</term>
<term>Humans</term>
<term>Lens Capsule, Crystalline (pathology)</term>
<term>Lens Capsule, Crystalline (surgery)</term>
<term>Lens Subluxation (etiology)</term>
<term>Lens Subluxation (surgery)</term>
<term>Phacoemulsification (adverse effects)</term>
<term>Prosthesis Failure</term>
<term>Reoperation</term>
<term>Visual Acuity</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en">
<term>Cataract Extraction</term>
<term>Phacoemulsification</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Eye Foreign Bodies</term>
<term>Foreign-Body Migration</term>
<term>Lens Subluxation</term>
</keywords>
<keywords scheme="MESH" qualifier="pathology" xml:lang="en">
<term>Lens Capsule, Crystalline</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Eye Foreign Bodies</term>
<term>Foreign-Body Migration</term>
<term>Lens Capsule, Crystalline</term>
<term>Lens Subluxation</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Contracture</term>
<term>Female</term>
<term>Humans</term>
<term>Prosthesis Failure</term>
<term>Reoperation</term>
<term>Visual Acuity</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Presentation of the case of the pseudophakic patient in whom 3 months after uncomplicated phacoemulsification severe capsule contraction syndrome, followed by equatorial capsule fibrosis, 240 degree zonular dialysis, and spontaneous in-the-bag intraocular lens subluxation, were observed. Consecutive surgical intervention consisting of simplified transscleral "free haptic" through the capsule fixation and additional plastic of phimotic capsulorrhexis allowed to restore the best corrected visual acuity to 20/25.</div>
</front>
</TEI>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Jurowski, Piotr" sort="Jurowski, Piotr" uniqKey="Jurowski P" first="Piotr" last="Jurowski">Piotr Jurowski</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 006171 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 006171 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:16619820
   |texte=   [Capsule contraction as a cause of in-the-bag intraocular lens subluxation and simplified technique of IOL reposition].
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:16619820" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024