Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Two-string technique to manage dislocated posterior chamber plate-haptic intraocular lens.

Identifieur interne : 005B20 ( Main/Exploration ); précédent : 005B19; suivant : 005B21

Two-string technique to manage dislocated posterior chamber plate-haptic intraocular lens.

Auteurs : Mohammad Fayez Rahim [Russie] ; Boris Malyugin

Source :

RBID : pubmed:16765786

English descriptors

Abstract

We describe a technique for repositioning and transscleral fixation of a dislocated plate-haptic foldable collamer posterior chamber intraocular lens (PC IOL). The displaced IOL was positioned in the anterior chamber, and a double-armed suture on a curved needle was fixed to the sclera at 10:30 o'clock. The needle then entered the globe and passed through the superior haptic eyelet of the IOL. Both were withdrawn through the scleral wound on the opposite side. The inferior haptic was fixed at 4:30 and 7:30 o'clock and provided the mirror reflection of the suture path of the upper fixed haptic. This technique may be a useful alternative to lens removal or exchange.

DOI: 10.1016/j.jcrs.2006.01.069
PubMed: 16765786


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Two-string technique to manage dislocated posterior chamber plate-haptic intraocular lens.</title>
<author>
<name sortKey="Rahim, Mohammad Fayez" sort="Rahim, Mohammad Fayez" uniqKey="Rahim M" first="Mohammad Fayez" last="Rahim">Mohammad Fayez Rahim</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Cataract and Implant Surgery, S. Fyodorov Eye Microsurgery Complex Federal State Institution, Moscow, Russia. faizrh@yahoo.com</nlm:affiliation>
<country xml:lang="fr">Russie</country>
<wicri:regionArea>Department of Cataract and Implant Surgery, S. Fyodorov Eye Microsurgery Complex Federal State Institution, Moscow</wicri:regionArea>
<placeName>
<settlement type="city">Moscou</settlement>
<region>District fédéral central</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Malyugin, Boris" sort="Malyugin, Boris" uniqKey="Malyugin B" first="Boris" last="Malyugin">Boris Malyugin</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2006">2006</date>
<idno type="doi">10.1016/j.jcrs.2006.01.069</idno>
<idno type="RBID">pubmed:16765786</idno>
<idno type="pmid">16765786</idno>
<idno type="wicri:Area/PubMed/Corpus">001785</idno>
<idno type="wicri:Area/PubMed/Curation">001785</idno>
<idno type="wicri:Area/PubMed/Checkpoint">001517</idno>
<idno type="wicri:Area/Ncbi/Merge">000939</idno>
<idno type="wicri:Area/Ncbi/Curation">000939</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">000939</idno>
<idno type="wicri:doubleKey">0886-3350:2006:Rahim M:two:string:technique</idno>
<idno type="wicri:Area/Main/Merge">005D21</idno>
<idno type="wicri:Area/Main/Curation">005B20</idno>
<idno type="wicri:Area/Main/Exploration">005B20</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Two-string technique to manage dislocated posterior chamber plate-haptic intraocular lens.</title>
<author>
<name sortKey="Rahim, Mohammad Fayez" sort="Rahim, Mohammad Fayez" uniqKey="Rahim M" first="Mohammad Fayez" last="Rahim">Mohammad Fayez Rahim</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Cataract and Implant Surgery, S. Fyodorov Eye Microsurgery Complex Federal State Institution, Moscow, Russia. faizrh@yahoo.com</nlm:affiliation>
<country xml:lang="fr">Russie</country>
<wicri:regionArea>Department of Cataract and Implant Surgery, S. Fyodorov Eye Microsurgery Complex Federal State Institution, Moscow</wicri:regionArea>
<placeName>
<settlement type="city">Moscou</settlement>
<region>District fédéral central</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Malyugin, Boris" sort="Malyugin, Boris" uniqKey="Malyugin B" first="Boris" last="Malyugin">Boris Malyugin</name>
</author>
</analytic>
<series>
<title level="j">Journal of cataract and refractive surgery</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<date when="2006" type="published">2006</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Anterior Chamber (surgery)</term>
<term>Foreign-Body Migration (surgery)</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Middle Aged</term>
<term>Prosthesis Failure</term>
<term>Reoperation</term>
<term>Sclera (surgery)</term>
<term>Suture Techniques</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Anterior Chamber</term>
<term>Foreign-Body Migration</term>
<term>Sclera</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Middle Aged</term>
<term>Prosthesis Failure</term>
<term>Reoperation</term>
<term>Suture Techniques</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">We describe a technique for repositioning and transscleral fixation of a dislocated plate-haptic foldable collamer posterior chamber intraocular lens (PC IOL). The displaced IOL was positioned in the anterior chamber, and a double-armed suture on a curved needle was fixed to the sclera at 10:30 o'clock. The needle then entered the globe and passed through the superior haptic eyelet of the IOL. Both were withdrawn through the scleral wound on the opposite side. The inferior haptic was fixed at 4:30 and 7:30 o'clock and provided the mirror reflection of the suture path of the upper fixed haptic. This technique may be a useful alternative to lens removal or exchange.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Russie</li>
</country>
<region>
<li>District fédéral central</li>
</region>
<settlement>
<li>Moscou</li>
</settlement>
</list>
<tree>
<noCountry>
<name sortKey="Malyugin, Boris" sort="Malyugin, Boris" uniqKey="Malyugin B" first="Boris" last="Malyugin">Boris Malyugin</name>
</noCountry>
<country name="Russie">
<region name="District fédéral central">
<name sortKey="Rahim, Mohammad Fayez" sort="Rahim, Mohammad Fayez" uniqKey="Rahim M" first="Mohammad Fayez" last="Rahim">Mohammad Fayez Rahim</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 005B20 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 005B20 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:16765786
   |texte=   Two-string technique to manage dislocated posterior chamber plate-haptic intraocular lens.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:16765786" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024