Comparison of Through-Focus Image Quality Across Five Presbyopia-Correcting Intraocular Lenses (An American Ophthalmological Society Thesis)
Identifieur interne : 002C70 ( Main/Exploration ); précédent : 002C69; suivant : 002C71Comparison of Through-Focus Image Quality Across Five Presbyopia-Correcting Intraocular Lenses (An American Ophthalmological Society Thesis)
Auteurs : Jay S. Pepose ; Daozhi Wang ; Griffith E. AltmannSource :
- Transactions of the American Ophthalmological Society [ 0065-9533 ] ; 2011.
Abstract
To assess through-focus polychromatic image sharpness of five US Food and Drug Administration–approved presbyopia-correcting intraocular lenses (IOLs) through a range of object vergences and pupil diameters utilizing an image sharpness algorithm.
A 1951 US Air Force resolution target was imaged through a Crystalens AO (AO) (Bausch & Lomb Surgical, Aliso Viejo, California), Crystalens HD (HD) (Bausch & Lomb Surgical, Aliso Viejo, California), aspheric ReSTOR +4.0 (R4) (Alcon Laboratories, Fort Worth, Texas), aspheric ReSTOR +3.0 (R3) (Alcon Laboratories, Fort Worth, Texas), and Tecnis Multifocal Acrylic (TMF) (Abbott Medical Optics, Irvine, California) IOL in an anatomically and optically accurate model eye and captured digitally for each combination of pupil diameter and object vergence. The sharpness of each digital image was objectively scored using a two-dimensional gradient function.
The AO lens had the best distance image sharpness for all pupil diameters, followed by the HD. With a 5-mm pupil, the R4 lens achieved distance image quality similar to the HD, but inferior to the AO. The R3 successfully moved the near focal point farther from the patient compared to the R4, but did not improve image sharpness at intermediate distances and showed worse distance and near image sharpness. Consistent with apodization, the ReSTOR IOLs displayed better distance and poorer near image sharpness as pupil diameter increased. The TMF lens showed consistent distance and near image sharpness across pupil diameters and exhibited the best near image sharpness for all pupil diameters.
Differing IOL design strategies to increase depth of field are associated with quantifiable differences in image sharpness at varying vergences and pupil sizes. An objective comparison of the imaging properties of specific presbyopia-correcting IOLs, in conjunction with patients’ pupil sizes, can be useful in selecting the most appropriate IOL for each patient.
Url:
PubMed: 22253489
PubMed Central: 3259672
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Pmc, to step Corpus: 001577
- to stream Pmc, to step Curation: 001577
- to stream Pmc, to step Checkpoint: 001C13
- to stream Ncbi, to step Merge: 001D70
- to stream Ncbi, to step Curation: 001D70
- to stream Ncbi, to step Checkpoint: 001D70
- to stream Main, to step Merge: 002D09
- to stream Main, to step Curation: 002C70
Le document en format XML
<record><TEI><teiHeader><fileDesc><titleStmt><title xml:lang="en">Comparison of Through-Focus Image Quality Across Five Presbyopia-Correcting Intraocular Lenses (An American Ophthalmological Society Thesis)</title>
<author><name sortKey="Pepose, Jay S" sort="Pepose, Jay S" uniqKey="Pepose J" first="Jay S." last="Pepose">Jay S. Pepose</name>
</author>
<author><name sortKey="Wang, Daozhi" sort="Wang, Daozhi" uniqKey="Wang D" first="Daozhi" last="Wang">Daozhi Wang</name>
</author>
<author><name sortKey="Altmann, Griffith E" sort="Altmann, Griffith E" uniqKey="Altmann G" first="Griffith E." last="Altmann">Griffith E. Altmann</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">PMC</idno>
<idno type="pmid">22253489</idno>
<idno type="pmc">3259672</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3259672</idno>
<idno type="RBID">PMC:3259672</idno>
<date when="2011">2011</date>
<idno type="wicri:Area/Pmc/Corpus">001577</idno>
<idno type="wicri:Area/Pmc/Curation">001577</idno>
<idno type="wicri:Area/Pmc/Checkpoint">001C13</idno>
<idno type="wicri:Area/Ncbi/Merge">001D70</idno>
<idno type="wicri:Area/Ncbi/Curation">001D70</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">001D70</idno>
<idno type="wicri:doubleKey">0065-9533:2011:Pepose J:comparison:of:through</idno>
<idno type="wicri:Area/Main/Merge">002D09</idno>
<idno type="wicri:Area/Main/Curation">002C70</idno>
<idno type="wicri:Area/Main/Exploration">002C70</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title xml:lang="en" level="a" type="main">Comparison of Through-Focus Image Quality Across Five Presbyopia-Correcting Intraocular Lenses (An American Ophthalmological Society Thesis)</title>
<author><name sortKey="Pepose, Jay S" sort="Pepose, Jay S" uniqKey="Pepose J" first="Jay S." last="Pepose">Jay S. Pepose</name>
</author>
<author><name sortKey="Wang, Daozhi" sort="Wang, Daozhi" uniqKey="Wang D" first="Daozhi" last="Wang">Daozhi Wang</name>
</author>
<author><name sortKey="Altmann, Griffith E" sort="Altmann, Griffith E" uniqKey="Altmann G" first="Griffith E." last="Altmann">Griffith E. Altmann</name>
</author>
</analytic>
<series><title level="j">Transactions of the American Ophthalmological Society</title>
<idno type="ISSN">0065-9533</idno>
<idno type="eISSN">1545-6110</idno>
<imprint><date when="2011">2011</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc><textClass></textClass>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en"><sec><title>Purpose</title>
<p>To assess through-focus polychromatic image sharpness of five US Food and Drug Administration–approved presbyopia-correcting intraocular lenses (IOLs) through a range of object vergences and pupil diameters utilizing an image sharpness algorithm.</p>
</sec>
<sec><title>Methods</title>
<p>A 1951 US Air Force resolution target was imaged through a Crystalens AO (AO) (Bausch & Lomb Surgical, Aliso Viejo, California), Crystalens HD (HD) (Bausch & Lomb Surgical, Aliso Viejo, California), aspheric ReSTOR +4.0 (R4) (Alcon Laboratories, Fort Worth, Texas), aspheric ReSTOR +3.0 (R3) (Alcon Laboratories, Fort Worth, Texas), and Tecnis Multifocal Acrylic (TMF) (Abbott Medical Optics, Irvine, California) IOL in an anatomically and optically accurate model eye and captured digitally for each combination of pupil diameter and object vergence. The sharpness of each digital image was objectively scored using a two-dimensional gradient function.</p>
</sec>
<sec><title>Results</title>
<p>The AO lens had the best distance image sharpness for all pupil diameters, followed by the HD. With a 5-mm pupil, the R4 lens achieved distance image quality similar to the HD, but inferior to the AO. The R3 successfully moved the near focal point farther from the patient compared to the R4, but did not improve image sharpness at intermediate distances and showed worse distance and near image sharpness. Consistent with apodization, the ReSTOR IOLs displayed better distance and poorer near image sharpness as pupil diameter increased. The TMF lens showed consistent distance and near image sharpness across pupil diameters and exhibited the best near image sharpness for all pupil diameters.</p>
</sec>
<sec><title>Conclusions</title>
<p>Differing IOL design strategies to increase depth of field are associated with quantifiable differences in image sharpness at varying vergences and pupil sizes. An objective comparison of the imaging properties of specific presbyopia-correcting IOLs, in conjunction with patients’ pupil sizes, can be useful in selecting the most appropriate IOL for each patient.</p>
</sec>
</div>
</front>
</TEI>
<affiliations><list></list>
<tree><noCountry><name sortKey="Altmann, Griffith E" sort="Altmann, Griffith E" uniqKey="Altmann G" first="Griffith E." last="Altmann">Griffith E. Altmann</name>
<name sortKey="Pepose, Jay S" sort="Pepose, Jay S" uniqKey="Pepose J" first="Jay S." last="Pepose">Jay S. Pepose</name>
<name sortKey="Wang, Daozhi" sort="Wang, Daozhi" uniqKey="Wang D" first="Daozhi" last="Wang">Daozhi Wang</name>
</noCountry>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002C70 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 002C70 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Main |étape= Exploration |type= RBID |clé= PMC:3259672 |texte= Comparison of Through-Focus Image Quality Across Five Presbyopia-Correcting Intraocular Lenses (An American Ophthalmological Society Thesis) }}
Pour générer des pages wiki
HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i -Sk "pubmed:22253489" \ | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd \ | NlmPubMed2Wicri -a HapticV1
![]() | This area was generated with Dilib version V0.6.23. | ![]() |