Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

AcrySof phakic angle-supported intraocular lens for the correction of high to extremely high myopia: one-year follow-up results

Identifieur interne : 002589 ( Main/Exploration ); précédent : 002588; suivant : 002590

AcrySof phakic angle-supported intraocular lens for the correction of high to extremely high myopia: one-year follow-up results

Auteurs : Rui-Bo Yang ; Shao-Zhen Zhao

Source :

RBID : PMC:3388408

Abstract

AIM

To assess the safety, efficacy and predictability of the AcrySof phakic angle-supported intraocular lens (IOL) (Alcon Inc., U.S.A.) for correction of high-to-extremely high myopia in adults.

METHODS

In this prospective study performed in Tianjin Medical University Eye Center & College of Optometry, Tianjin, China, 25 eyes of 13 patients were implanted with AcrySof phakic angle-supported IOLs and followed for 1 year postoperatively. Preoperative manifest refractive sphere was (-12.08±2.44) diopters (D) and cylinder was (-1.35±0.62)D. Visual acuity, predictability and stability of manifest refraction spherical equivalent (MRSE), adverse events, and endothelial cell density were analyzed during 1-year of follow-up.

RESULTS

After 1 year of follow-up, no eyes lost≥1 line (best spectacle-corrected visual acuity)BSCVA; an uncorrected visual acuity (UCVA) of 20/20 or better was achieved in 60% of eyes; 100% had an UCVA of 20/40 or better; a BSCVA of 20/30 or better was achieved by 100% of eyes; 84% had a BSCVA of 20/20 or better. The overall mean percentage change in endothelial cell density 1 year after surgery was (-0.27±3.60)%. Two eyes (8%) had increased intraocular pressure (IOP) on the day of surgery. No pupil ovalization, pupillary block, or retinal detachment events were observed.

CONCLUSION

After 1 year of follow-up, the implantation of AcrySof phakic angle-supported IOL is proved to be safe, effective and predictable with minimal complications in patients with high-to-extremely high myopia. Due to the limitation of visiting time, long-term of clinical investigation is necessary to verify the safety and efficacy of this IOL.


Url:
DOI: 10.3980/j.issn.2222-3959.2012.03.21
PubMed: 22773988
PubMed Central: 3388408


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">AcrySof phakic angle-supported intraocular lens for the correction of high to extremely high myopia: one-year follow-up results</title>
<author>
<name sortKey="Yang, Rui Bo" sort="Yang, Rui Bo" uniqKey="Yang R" first="Rui-Bo" last="Yang">Rui-Bo Yang</name>
</author>
<author>
<name sortKey="Zhao, Shao Zhen" sort="Zhao, Shao Zhen" uniqKey="Zhao S" first="Shao-Zhen" last="Zhao">Shao-Zhen Zhao</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">22773988</idno>
<idno type="pmc">3388408</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3388408</idno>
<idno type="RBID">PMC:3388408</idno>
<idno type="doi">10.3980/j.issn.2222-3959.2012.03.21</idno>
<date when="2012">2012</date>
<idno type="wicri:Area/Pmc/Corpus">001348</idno>
<idno type="wicri:Area/Pmc/Curation">001348</idno>
<idno type="wicri:Area/Pmc/Checkpoint">001872</idno>
<idno type="wicri:Area/Ncbi/Merge">002121</idno>
<idno type="wicri:Area/Ncbi/Curation">002121</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">002121</idno>
<idno type="wicri:doubleKey">2222-3959:2012:Yang R:acrysof:phakic:angle</idno>
<idno type="wicri:Area/Main/Merge">002617</idno>
<idno type="wicri:Area/Main/Curation">002589</idno>
<idno type="wicri:Area/Main/Exploration">002589</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">AcrySof phakic angle-supported intraocular lens for the correction of high to extremely high myopia: one-year follow-up results</title>
<author>
<name sortKey="Yang, Rui Bo" sort="Yang, Rui Bo" uniqKey="Yang R" first="Rui-Bo" last="Yang">Rui-Bo Yang</name>
</author>
<author>
<name sortKey="Zhao, Shao Zhen" sort="Zhao, Shao Zhen" uniqKey="Zhao S" first="Shao-Zhen" last="Zhao">Shao-Zhen Zhao</name>
</author>
</analytic>
<series>
<title level="j">International Journal of Ophthalmology</title>
<idno type="ISSN">2222-3959</idno>
<idno type="eISSN">2227-4898</idno>
<imprint>
<date when="2012">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<sec>
<title>AIM</title>
<p>To assess the safety, efficacy and predictability of the AcrySof phakic angle-supported intraocular lens (IOL) (Alcon Inc., U.S.A.) for correction of high-to-extremely high myopia in adults.</p>
</sec>
<sec>
<title>METHODS</title>
<p>In this prospective study performed in Tianjin Medical University Eye Center & College of Optometry, Tianjin, China, 25 eyes of 13 patients were implanted with AcrySof phakic angle-supported IOLs and followed for 1 year postoperatively. Preoperative manifest refractive sphere was (-12.08±2.44) diopters (D) and cylinder was (-1.35±0.62)D. Visual acuity, predictability and stability of manifest refraction spherical equivalent (MRSE), adverse events, and endothelial cell density were analyzed during 1-year of follow-up.</p>
</sec>
<sec>
<title>RESULTS</title>
<p>After 1 year of follow-up, no eyes lost≥1 line (best spectacle-corrected visual acuity)BSCVA; an uncorrected visual acuity (UCVA) of 20/20 or better was achieved in 60% of eyes; 100% had an UCVA of 20/40 or better; a BSCVA of 20/30 or better was achieved by 100% of eyes; 84% had a BSCVA of 20/20 or better. The overall mean percentage change in endothelial cell density 1 year after surgery was (-0.27±3.60)%. Two eyes (8%) had increased intraocular pressure (IOP) on the day of surgery. No pupil ovalization, pupillary block, or retinal detachment events were observed.</p>
</sec>
<sec>
<title>CONCLUSION</title>
<p>After 1 year of follow-up, the implantation of AcrySof phakic angle-supported IOL is proved to be safe, effective and predictable with minimal complications in patients with high-to-extremely high myopia. Due to the limitation of visiting time, long-term of clinical investigation is necessary to verify the safety and efficacy of this IOL.</p>
</sec>
</div>
</front>
</TEI>
<affiliations>
<list></list>
<tree>
<noCountry>
<name sortKey="Yang, Rui Bo" sort="Yang, Rui Bo" uniqKey="Yang R" first="Rui-Bo" last="Yang">Rui-Bo Yang</name>
<name sortKey="Zhao, Shao Zhen" sort="Zhao, Shao Zhen" uniqKey="Zhao S" first="Shao-Zhen" last="Zhao">Shao-Zhen Zhao</name>
</noCountry>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002589 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 002589 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     PMC:3388408
   |texte=   AcrySof phakic angle-supported intraocular lens for the correction of high to extremely high myopia: one-year follow-up results
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:22773988" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024