Spontaneous dislocation of intraocular lens as a late complication of uncomplicated cataract surgery: a case series.

Identifieur interne : 002170 ( Main/Exploration ); précédent : 002169; suivant : 002171

Spontaneous dislocation of intraocular lens as a late complication of uncomplicated cataract surgery: a case series.

Auteurs : Hee Hong Lam [Malaisie] ; Subrayan Visvaraja

Source :

RBID : pubmed:21954950

English descriptors

Abstract

Five patients having uncomplicated phacoemulsification were implanted with CT-Asphina 603P intraocular lenses into the capsular bag. After a few months, three of the patients had haptic flexion anterior to the optic despite minimal capsular fibrosis. One patient had spontaneous dislocation of the intraocular lens into the anterior chamber with only minimal capsular fibrosis. Another patient had one haptic dislocated out of the bag. Late intraocular lens dislocation is also seen in newly designed preloaded intraocular lenses despite the absence of significant capsular fibrosis. Haptic-optic junction design and intraocular lens material play important roles in such complication. A slightly large capsulorhexis might be a deterrent for implantation of this intraocular lens.

DOI: 10.1111/j.1444-0938.2011.00640.x
PubMed: 21954950


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Spontaneous dislocation of intraocular lens as a late complication of uncomplicated cataract surgery: a case series.</title>
<author>
<name sortKey="Lam, Hee Hong" sort="Lam, Hee Hong" uniqKey="Lam H" first="Hee Hong" last="Lam">Hee Hong Lam</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Ophthalmology, University of Malaya, Kuala Lumpur, Malaysia. lamheehong@yahoo.com.my</nlm:affiliation>
<country xml:lang="fr">Malaisie</country>
<wicri:regionArea>Department of Ophthalmology, University of Malaya, Kuala Lumpur</wicri:regionArea>
<wicri:noRegion>Kuala Lumpur</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Visvaraja, Subrayan" sort="Visvaraja, Subrayan" uniqKey="Visvaraja S" first="Subrayan" last="Visvaraja">Subrayan Visvaraja</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2012">2012</date>
<idno type="doi">10.1111/j.1444-0938.2011.00640.x</idno>
<idno type="RBID">pubmed:21954950</idno>
<idno type="pmid">21954950</idno>
<idno type="wicri:Area/PubMed/Corpus">000E06</idno>
<idno type="wicri:Area/PubMed/Curation">000E06</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000A45</idno>
<idno type="wicri:Area/Ncbi/Merge">001C06</idno>
<idno type="wicri:Area/Ncbi/Curation">001C06</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">001C06</idno>
<idno type="wicri:Area/Main/Merge">002194</idno>
<idno type="wicri:Area/Main/Curation">002170</idno>
<idno type="wicri:Area/Main/Exploration">002170</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Spontaneous dislocation of intraocular lens as a late complication of uncomplicated cataract surgery: a case series.</title>
<author>
<name sortKey="Lam, Hee Hong" sort="Lam, Hee Hong" uniqKey="Lam H" first="Hee Hong" last="Lam">Hee Hong Lam</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Ophthalmology, University of Malaya, Kuala Lumpur, Malaysia. lamheehong@yahoo.com.my</nlm:affiliation>
<country xml:lang="fr">Malaisie</country>
<wicri:regionArea>Department of Ophthalmology, University of Malaya, Kuala Lumpur</wicri:regionArea>
<wicri:noRegion>Kuala Lumpur</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Visvaraja, Subrayan" sort="Visvaraja, Subrayan" uniqKey="Visvaraja S" first="Subrayan" last="Visvaraja">Subrayan Visvaraja</name>
</author>
</analytic>
<series>
<title level="j">Clinical & experimental optometry</title>
<idno type="eISSN">1444-0938</idno>
<imprint>
<date when="2012" type="published">2012</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Aged</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Foreign-Body Migration (diagnosis)</term>
<term>Foreign-Body Migration (etiology)</term>
<term>Foreign-Body Migration (surgery)</term>
<term>Humans</term>
<term>Lens Subluxation (diagnosis)</term>
<term>Lens Subluxation (etiology)</term>
<term>Lens Subluxation (surgery)</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Phacoemulsification (adverse effects)</term>
<term>Postoperative Complications</term>
<term>Prosthesis Failure</term>
<term>Reoperation</term>
<term>Time Factors</term>
</keywords>
<keywords scheme="MESH" qualifier="adverse effects" xml:lang="en">
<term>Phacoemulsification</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnosis" xml:lang="en">
<term>Foreign-Body Migration</term>
<term>Lens Subluxation</term>
</keywords>
<keywords scheme="MESH" qualifier="etiology" xml:lang="en">
<term>Foreign-Body Migration</term>
<term>Lens Subluxation</term>
</keywords>
<keywords scheme="MESH" qualifier="surgery" xml:lang="en">
<term>Foreign-Body Migration</term>
<term>Lens Subluxation</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Aged</term>
<term>Female</term>
<term>Follow-Up Studies</term>
<term>Humans</term>
<term>Lenses, Intraocular</term>
<term>Male</term>
<term>Postoperative Complications</term>
<term>Prosthesis Failure</term>
<term>Reoperation</term>
<term>Time Factors</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Five patients having uncomplicated phacoemulsification were implanted with CT-Asphina 603P intraocular lenses into the capsular bag. After a few months, three of the patients had haptic flexion anterior to the optic despite minimal capsular fibrosis. One patient had spontaneous dislocation of the intraocular lens into the anterior chamber with only minimal capsular fibrosis. Another patient had one haptic dislocated out of the bag. Late intraocular lens dislocation is also seen in newly designed preloaded intraocular lenses despite the absence of significant capsular fibrosis. Haptic-optic junction design and intraocular lens material play important roles in such complication. A slightly large capsulorhexis might be a deterrent for implantation of this intraocular lens.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Malaisie</li>
</country>
</list>
<tree>
<noCountry>
<name sortKey="Visvaraja, Subrayan" sort="Visvaraja, Subrayan" uniqKey="Visvaraja S" first="Subrayan" last="Visvaraja">Subrayan Visvaraja</name>
</noCountry>
<country name="Malaisie">
<noRegion>
<name sortKey="Lam, Hee Hong" sort="Lam, Hee Hong" uniqKey="Lam H" first="Hee Hong" last="Lam">Hee Hong Lam</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 002170 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 002170 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:21954950
   |texte=   Spontaneous dislocation of intraocular lens as a late complication of uncomplicated cataract surgery: a case series.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:21954950" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024