A safe method of ciliary sulcus fixation of foldable intraocular lens using a ciliary sulcus guide.

Identifieur interne : 000B43 ( Main/Exploration ); précédent : 000B42; suivant : 000B44

A safe method of ciliary sulcus fixation of foldable intraocular lens using a ciliary sulcus guide.

Auteurs : Ertu Rul Can [Turquie] ; Adem Gül [Turquie] ; Hakk Birinci [Turquie]

Source :

RBID : pubmed:26439372

Abstract

To describe a novel technique for implantation of intraocular lens in the absence of capsular support using a ciliary sulcus guide. Based on the anatomic knowledge of the ciliary sulcus and the sclera, a new instrument was developed to pierce the needle safely through the ciliary sulcus and sclera. While the foldable lens is stored inside the cartridge, the leading haptic is sutured with a cow-hitch knot. The needle is then inserted into the ciliary sulcus guide. The tip of the guide is inserted from the corneal incision and proceeded under the iris to touch and fit the ciliary sulcus. The needle is pushed from back side. The needle comes out at precise point at the sclera. Implantation of the lens was performed through a 2.8 mm clear cornea incision using the injector. The trailing haptic is tied after implantation, and then the same procedure is performed at the opposite side. We performed this technique to 15 aphakic eyes without sufficient capsular support. There was no bleeding or other intraoperative complication. All the points coming out the sclera were between 2 and 2.5 mm from the limbus. The ab interno technique for scleral fixation of IOL is quicker, easier and less traumatic then ab externo techniques. A new ciliary sulcus guide which is usable with both straight and curved needles eliminates the blind maneuvers of ab interno technique and makes this technique more safe and precise.

DOI: 10.1007/s10792-015-0132-0
PubMed: 26439372


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">A safe method of ciliary sulcus fixation of foldable intraocular lens using a ciliary sulcus guide.</title>
<author>
<name sortKey="Can, Ertu Rul" sort="Can, Ertu Rul" uniqKey="Can E" first="Ertu Rul" last="Can">Ertu Rul Can</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Ophthalmology, Faculty of Medicine, Ondokuz Mayis University, 55139, Samsun, Turkey. canertugrul73@hotmail.com.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Ophthalmology, Faculty of Medicine, Ondokuz Mayis University, 55139, Samsun</wicri:regionArea>
<wicri:noRegion>Samsun</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Gul, Adem" sort="Gul, Adem" uniqKey="Gul A" first="Adem" last="Gül">Adem Gül</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Ophthalmology, Faculty of Medicine, Ondokuz Mayis University, 55139, Samsun, Turkey.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Ophthalmology, Faculty of Medicine, Ondokuz Mayis University, 55139, Samsun</wicri:regionArea>
<wicri:noRegion>Samsun</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Birinci, Hakk" sort="Birinci, Hakk" uniqKey="Birinci H" first="Hakk" last="Birinci">Hakk Birinci</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Ophthalmology, Faculty of Medicine, Ondokuz Mayis University, 55139, Samsun, Turkey.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Ophthalmology, Faculty of Medicine, Ondokuz Mayis University, 55139, Samsun</wicri:regionArea>
<wicri:noRegion>Samsun</wicri:noRegion>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="2015">2015</date>
<idno type="doi">10.1007/s10792-015-0132-0</idno>
<idno type="RBID">pubmed:26439372</idno>
<idno type="pmid">26439372</idno>
<idno type="wicri:Area/PubMed/Corpus">000235</idno>
<idno type="wicri:Area/PubMed/Curation">000235</idno>
<idno type="wicri:Area/PubMed/Checkpoint">000441</idno>
<idno type="wicri:Area/Ncbi/Merge">003C69</idno>
<idno type="wicri:Area/Ncbi/Curation">003C69</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">003C69</idno>
<idno type="wicri:Area/Main/Merge">000B43</idno>
<idno type="wicri:Area/Main/Curation">000B43</idno>
<idno type="wicri:Area/Main/Exploration">000B43</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">A safe method of ciliary sulcus fixation of foldable intraocular lens using a ciliary sulcus guide.</title>
<author>
<name sortKey="Can, Ertu Rul" sort="Can, Ertu Rul" uniqKey="Can E" first="Ertu Rul" last="Can">Ertu Rul Can</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Ophthalmology, Faculty of Medicine, Ondokuz Mayis University, 55139, Samsun, Turkey. canertugrul73@hotmail.com.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Ophthalmology, Faculty of Medicine, Ondokuz Mayis University, 55139, Samsun</wicri:regionArea>
<wicri:noRegion>Samsun</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Gul, Adem" sort="Gul, Adem" uniqKey="Gul A" first="Adem" last="Gül">Adem Gül</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Ophthalmology, Faculty of Medicine, Ondokuz Mayis University, 55139, Samsun, Turkey.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Ophthalmology, Faculty of Medicine, Ondokuz Mayis University, 55139, Samsun</wicri:regionArea>
<wicri:noRegion>Samsun</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Birinci, Hakk" sort="Birinci, Hakk" uniqKey="Birinci H" first="Hakk" last="Birinci">Hakk Birinci</name>
<affiliation wicri:level="1">
<nlm:affiliation>Department of Ophthalmology, Faculty of Medicine, Ondokuz Mayis University, 55139, Samsun, Turkey.</nlm:affiliation>
<country xml:lang="fr">Turquie</country>
<wicri:regionArea>Department of Ophthalmology, Faculty of Medicine, Ondokuz Mayis University, 55139, Samsun</wicri:regionArea>
<wicri:noRegion>Samsun</wicri:noRegion>
</affiliation>
</author>
</analytic>
<series>
<title level="j">International ophthalmology</title>
<idno type="eISSN">1573-2630</idno>
<imprint>
<date when="2015" type="published">2015</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">To describe a novel technique for implantation of intraocular lens in the absence of capsular support using a ciliary sulcus guide. Based on the anatomic knowledge of the ciliary sulcus and the sclera, a new instrument was developed to pierce the needle safely through the ciliary sulcus and sclera. While the foldable lens is stored inside the cartridge, the leading haptic is sutured with a cow-hitch knot. The needle is then inserted into the ciliary sulcus guide. The tip of the guide is inserted from the corneal incision and proceeded under the iris to touch and fit the ciliary sulcus. The needle is pushed from back side. The needle comes out at precise point at the sclera. Implantation of the lens was performed through a 2.8 mm clear cornea incision using the injector. The trailing haptic is tied after implantation, and then the same procedure is performed at the opposite side. We performed this technique to 15 aphakic eyes without sufficient capsular support. There was no bleeding or other intraoperative complication. All the points coming out the sclera were between 2 and 2.5 mm from the limbus. The ab interno technique for scleral fixation of IOL is quicker, easier and less traumatic then ab externo techniques. A new ciliary sulcus guide which is usable with both straight and curved needles eliminates the blind maneuvers of ab interno technique and makes this technique more safe and precise.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Turquie</li>
</country>
</list>
<tree>
<country name="Turquie">
<noRegion>
<name sortKey="Can, Ertu Rul" sort="Can, Ertu Rul" uniqKey="Can E" first="Ertu Rul" last="Can">Ertu Rul Can</name>
</noRegion>
<name sortKey="Birinci, Hakk" sort="Birinci, Hakk" uniqKey="Birinci H" first="Hakk" last="Birinci">Hakk Birinci</name>
<name sortKey="Gul, Adem" sort="Gul, Adem" uniqKey="Gul A" first="Adem" last="Gül">Adem Gül</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000B43 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000B43 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:26439372
   |texte=   A safe method of ciliary sulcus fixation of foldable intraocular lens using a ciliary sulcus guide.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:26439372" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024