Serveur d'exploration sur les dispositifs haptiques

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Design and Evaluation of Identifiable Key-Click Signals for Mobile Devices.

Identifieur interne : 00A670 ( Main/Curation ); précédent : 00A669; suivant : 00A671

Design and Evaluation of Identifiable Key-Click Signals for Mobile Devices.

Auteurs : Hsiang-Yu Chen ; Jaeyoung Park ; S. Dai ; H Z Tan

Source :

RBID : pubmed:26963652

Abstract

As touch based input becomes more popular in mobile devices, there is an increasing need for haptic feedback on key-less input surface. Four experiments were conducted to design and evaluate identifiable emulated key-click signals using a piezoelectric actuator. Experiments I and II assessed the information transmission capacity for the amplitude, frequency, and number of cycles of raised cosine waveforms used to drive the piezo actuators under fixed- and roving-background conditions, respectively. Experiment III estimated the total information transfer for all three parameters. The results were used to reduce the number of stimulus alternatives in the key-click signal set with the goal to achieve perfect identification performance. Experiment IV verified that up to 5 to 6 identifiable key-click signals could be achieved with the experimental setup. The present study outlines an information theoretic approach to conducting identification experiments to guide the design of and to evaluate a perfectly identifiable stimulus set. The methodology can be applied to other applications in need of perceptually identifiable stimulation patterns.

DOI: 10.1109/TOH.2011.21
PubMed: 26963652

Links toward previous steps (curation, corpus...)


Links to Exploration step

pubmed:26963652

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Design and Evaluation of Identifiable Key-Click Signals for Mobile Devices.</title>
<author>
<name sortKey="Hsiang Yu Chen" sort="Hsiang Yu Chen" uniqKey="Hsiang Yu Chen" last="Hsiang-Yu Chen">Hsiang-Yu Chen</name>
</author>
<author>
<name sortKey="Jaeyoung Park" sort="Jaeyoung Park" uniqKey="Jaeyoung Park" last="Jaeyoung Park">Jaeyoung Park</name>
</author>
<author>
<name sortKey="Dai, S" sort="Dai, S" uniqKey="Dai S" first="S" last="Dai">S. Dai</name>
</author>
<author>
<name sortKey="Tan, H Z" sort="Tan, H Z" uniqKey="Tan H" first="H Z" last="Tan">H Z Tan</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="????">
<PubDate>
<MedlineDate>2011 Jul-Aug</MedlineDate>
</PubDate>
</date>
<idno type="doi">10.1109/TOH.2011.21</idno>
<idno type="RBID">pubmed:26963652</idno>
<idno type="pmid">26963652</idno>
<idno type="wicri:Area/PubMed/Corpus">000E41</idno>
<idno type="wicri:Area/PubMed/Curation">000E41</idno>
<idno type="wicri:Area/PubMed/Checkpoint">002420</idno>
<idno type="wicri:Area/Ncbi/Merge">004054</idno>
<idno type="wicri:Area/Ncbi/Curation">004054</idno>
<idno type="wicri:Area/Ncbi/Checkpoint">004054</idno>
<idno type="wicri:doubleKey">1939-1412::Hsiang Yu Chen:design:and:evaluation</idno>
<idno type="wicri:Area/Main/Merge">00B215</idno>
<idno type="wicri:Area/Main/Curation">00A670</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Design and Evaluation of Identifiable Key-Click Signals for Mobile Devices.</title>
<author>
<name sortKey="Hsiang Yu Chen" sort="Hsiang Yu Chen" uniqKey="Hsiang Yu Chen" last="Hsiang-Yu Chen">Hsiang-Yu Chen</name>
</author>
<author>
<name sortKey="Jaeyoung Park" sort="Jaeyoung Park" uniqKey="Jaeyoung Park" last="Jaeyoung Park">Jaeyoung Park</name>
</author>
<author>
<name sortKey="Dai, S" sort="Dai, S" uniqKey="Dai S" first="S" last="Dai">S. Dai</name>
</author>
<author>
<name sortKey="Tan, H Z" sort="Tan, H Z" uniqKey="Tan H" first="H Z" last="Tan">H Z Tan</name>
</author>
</analytic>
<series>
<title level="j">IEEE transactions on haptics</title>
<idno type="ISSN">1939-1412</idno>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">As touch based input becomes more popular in mobile devices, there is an increasing need for haptic feedback on key-less input surface. Four experiments were conducted to design and evaluate identifiable emulated key-click signals using a piezoelectric actuator. Experiments I and II assessed the information transmission capacity for the amplitude, frequency, and number of cycles of raised cosine waveforms used to drive the piezo actuators under fixed- and roving-background conditions, respectively. Experiment III estimated the total information transfer for all three parameters. The results were used to reduce the number of stimulus alternatives in the key-click signal set with the goal to achieve perfect identification performance. Experiment IV verified that up to 5 to 6 identifiable key-click signals could be achieved with the experimental setup. The present study outlines an information theoretic approach to conducting identification experiments to guide the design of and to evaluate a perfectly identifiable stimulus set. The methodology can be applied to other applications in need of perceptually identifiable stimulation patterns.</div>
</front>
</TEI>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Main/Curation
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 00A670 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Curation/biblio.hfd -nk 00A670 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Main
   |étape=   Curation
   |type=    RBID
   |clé=     pubmed:26963652
   |texte=   Design and Evaluation of Identifiable Key-Click Signals for Mobile Devices.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Curation/RBID.i   -Sk "pubmed:26963652" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Curation/biblio.hfd   \
       | NlmPubMed2Wicri -a HapticV1 

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024