A simple snare for transscleral fixation of dislocated intraocular lenses

Identifieur interne : 000F55 ( Istex/Corpus ); précédent : 000F54; suivant : 000F56

A simple snare for transscleral fixation of dislocated intraocular lenses

Auteurs : Alex Poon ; J Ben Clark ; Rodney Hb Grey ; Richard Hc Markham

Source :

RBID : ISTEX:B230995F43F9136B8EB0DE12B879D81499C5A781

Abstract

Purpose:The construction and use of a surgical snare in retrieving and securing posterior chamber intraocular lenses is described. Methods:The snare consists of a 10‐0 polypropylene suture threaded into a 25‐gauge ret‐robulbar needle. This is used after a pars plana vitrectomy to retrieve the dislocated intraocular lens. The needle attached to the polypropylene suture is used to secure the lens haptic 1.5 mm behind the limbus. Two snares are used to secure the two lens haptics. Conclusions:The snare is easy to make with readily available materials. The use of this snare involves less intraocular and extraocular manipulations than other described methods.

Url:
DOI: 10.1111/j.1442-9071.1996.tb01614.x

Links to Exploration step

ISTEX:B230995F43F9136B8EB0DE12B879D81499C5A781

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="no">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">A simple snare for transscleral fixation of dislocated intraocular lenses</title>
<author>
<name sortKey="Poon, Alex" sort="Poon, Alex" uniqKey="Poon A" first="Alex" last="Poon">Alex Poon</name>
<affiliation>
<mods:affiliation>*Geelong Hospital</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Clark, J Ben" sort="Clark, J Ben" uniqKey="Clark J" first="J Ben" last="Clark">J Ben Clark</name>
<affiliation>
<mods:affiliation>*Geelong Hospital</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Grey, Rodney Hb" sort="Grey, Rodney Hb" uniqKey="Grey R" first="Rodney Hb" last="Grey">Rodney Hb Grey</name>
<affiliation>
<mods:affiliation>†Bristol Eye Hospital</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Markham, Richard Hc" sort="Markham, Richard Hc" uniqKey="Markham R" first="Richard Hc" last="Markham">Richard Hc Markham</name>
<affiliation>
<mods:affiliation>†Bristol Eye Hospital</mods:affiliation>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:B230995F43F9136B8EB0DE12B879D81499C5A781</idno>
<date when="1996" year="1996">1996</date>
<idno type="doi">10.1111/j.1442-9071.1996.tb01614.x</idno>
<idno type="url">https://api.istex.fr/document/B230995F43F9136B8EB0DE12B879D81499C5A781/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000F55</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<author>
<name sortKey="Poon, Alex" sort="Poon, Alex" uniqKey="Poon A" first="Alex" last="Poon">Alex Poon</name>
<affiliation>
<mods:affiliation>*Geelong Hospital</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Clark, J Ben" sort="Clark, J Ben" uniqKey="Clark J" first="J Ben" last="Clark">J Ben Clark</name>
<affiliation>
<mods:affiliation>*Geelong Hospital</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Grey, Rodney Hb" sort="Grey, Rodney Hb" uniqKey="Grey R" first="Rodney Hb" last="Grey">Rodney Hb Grey</name>
<affiliation>
<mods:affiliation>†Bristol Eye Hospital</mods:affiliation>
</affiliation>
</author>
<author>
<name sortKey="Markham, Richard Hc" sort="Markham, Richard Hc" uniqKey="Markham R" first="Richard Hc" last="Markham">Richard Hc Markham</name>
<affiliation>
<mods:affiliation>†Bristol Eye Hospital</mods:affiliation>
</affiliation>
</author>
</analytic>
<series>
<idno type="ISSN">0814-9763</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0814-9763</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Purpose:The construction and use of a surgical snare in retrieving and securing posterior chamber intraocular lenses is described. Methods:The snare consists of a 10‐0 polypropylene suture threaded into a 25‐gauge ret‐robulbar needle. This is used after a pars plana vitrectomy to retrieve the dislocated intraocular lens. The needle attached to the polypropylene suture is used to secure the lens haptic 1.5 mm behind the limbus. Two snares are used to secure the two lens haptics. Conclusions:The snare is easy to make with readily available materials. The use of this snare involves less intraocular and extraocular manipulations than other described methods.</div>
</front>
</TEI>
<istex>
<corpusName>wiley</corpusName>
<author>
<json:item>
<name>Alex Poon MB BS</name>
<affiliations>
<json:string>*Geelong Hospital</json:string>
</affiliations>
</json:item>
<json:item>
<name>J Ben Clark FRACS, FRACO</name>
<affiliations>
<json:string>*Geelong Hospital</json:string>
</affiliations>
</json:item>
<json:item>
<name>Rodney HB Grey FRCO</name>
<affiliations>
<json:string>†Bristol Eye Hospital</json:string>
</affiliations>
</json:item>
<json:item>
<name>Richard HC Markham FRCO</name>
<affiliations>
<json:string>†Bristol Eye Hospital</json:string>
</affiliations>
</json:item>
</author>
<subject>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>Dislocation</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>posterior chamber intraocular lens</value>
</json:item>
<json:item>
<lang>
<json:string>eng</json:string>
</lang>
<value>snare</value>
</json:item>
</subject>
<articleId>
<json:string>CEO385</json:string>
</articleId>
<language>
<json:string>eng</json:string>
</language>
<abstract>Purpose:The construction and use of a surgical snare in retrieving and securing posterior chamber intraocular lenses is described. Methods:The snare consists of a 10‐0 polypropylene suture threaded into a 25‐gauge ret‐robulbar needle. This is used after a pars plana vitrectomy to retrieve the dislocated intraocular lens. The needle attached to the polypropylene suture is used to secure the lens haptic 1.5 mm behind the limbus. Two snares are used to secure the two lens haptics. Conclusions:The snare is easy to make with readily available materials. The use of this snare involves less intraocular and extraocular manipulations than other described methods.</abstract>
<qualityIndicators>
<score>2.836</score>
<pdfVersion>1.3</pdfVersion>
<pdfPageSize>576 x 792 pts</pdfPageSize>
<refBibsNative>true</refBibsNative>
<keywordCount>3</keywordCount>
<abstractCharCount>662</abstractCharCount>
<pdfWordCount>1636</pdfWordCount>
<pdfCharCount>9351</pdfCharCount>
<pdfPageCount>4</pdfPageCount>
<abstractWordCount>100</abstractWordCount>
</qualityIndicators>
<title>A simple snare for transscleral fixation of dislocated intraocular lenses</title>
<genre.original>
<json:string>miscellaneous</json:string>
</genre.original>
<genre>
<json:string>other</json:string>
</genre>
<host>
<volume>24</volume>
<publisherId>
<json:string>CEO</json:string>
</publisherId>
<pages>
<total>4</total>
<last>388</last>
<first>385</first>
</pages>
<issn>
<json:string>0814-9763</json:string>
</issn>
<issue>4</issue>
<genre>
<json:string>journal</json:string>
</genre>
<language>
<json:string>unknown</json:string>
</language>
<eissn>
<json:string>1440-1606</json:string>
</eissn>
<title>Australian and New Zealand Journal of Ophthalmology</title>
<doi>
<json:string>10.1111/(ISSN)1440-1606</json:string>
</doi>
</host>
<publicationDate>1996</publicationDate>
<copyrightDate>1996</copyrightDate>
<doi>
<json:string>10.1111/j.1442-9071.1996.tb01614.x</json:string>
</doi>
<id>B230995F43F9136B8EB0DE12B879D81499C5A781</id>
<score>1</score>
<fulltext>
<json:item>
<original>true</original>
<mimetype>application/pdf</mimetype>
<extension>pdf</extension>
<uri>https://api.istex.fr/document/B230995F43F9136B8EB0DE12B879D81499C5A781/fulltext/pdf</uri>
</json:item>
<json:item>
<original>false</original>
<mimetype>application/zip</mimetype>
<extension>zip</extension>
<uri>https://api.istex.fr/document/B230995F43F9136B8EB0DE12B879D81499C5A781/fulltext/zip</uri>
</json:item>
<json:item>
<original>false</original>
<mimetype>text/plain</mimetype>
<extension>txt</extension>
<uri>https://api.istex.fr/document/B230995F43F9136B8EB0DE12B879D81499C5A781/fulltext/txt</uri>
</json:item>
</fulltext>
<metadata>
<istex:metadataXml wicri:clean="Wiley, elements deleted: body">
<istex:xmlDeclaration>version="1.0" encoding="UTF-8" standalone="yes"</istex:xmlDeclaration>
<istex:document>
<component version="2.0" type="serialArticle" xml:lang="en">
<header>
<publicationMeta level="product">
<publisherInfo>
<publisherName>Blackwell Publishing Ltd</publisherName>
<publisherLoc>Oxford, UK</publisherLoc>
</publisherInfo>
<doi origin="wiley" registered="yes">10.1111/(ISSN)1440-1606</doi>
<issn type="print">0814-9763</issn>
<issn type="electronic">1440-1606</issn>
<idGroup>
<id type="product" value="CEO"></id>
<id type="publisherDivision" value="ST"></id>
</idGroup>
<titleGroup>
<title type="main" sort="AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY">Australian and New Zealand Journal of Ophthalmology</title>
</titleGroup>
</publicationMeta>
<publicationMeta level="part" position="11004">
<doi origin="wiley">10.1111/ceo.1996.24.issue-4</doi>
<numberingGroup>
<numbering type="journalVolume" number="24">24</numbering>
<numbering type="journalIssue" number="4">4</numbering>
</numberingGroup>
<coverDate startDate="1996-11">November 1996</coverDate>
</publicationMeta>
<publicationMeta level="unit" type="miscellaneous" position="0038500" status="forIssue">
<doi origin="wiley">10.1111/j.1442-9071.1996.tb01614.x</doi>
<idGroup>
<id type="unit" value="CEO385"></id>
</idGroup>
<countGroup>
<count type="pageTotal" number="4"></count>
</countGroup>
<titleGroup>
<title type="tocHeading1">Surgical Technique</title>
</titleGroup>
<eventGroup>
<event type="firstOnline" date="2007-11-07"></event>
<event type="publishedOnlineFinalForm" date="2009-12-07"></event>
<event type="xmlConverted" agent="Converter:BPG_TO_WML3G version:2.3.6 mode:FullText source:HeaderRef result:HeaderRef" date="2010-04-21"></event>
<event type="xmlConverted" agent="Converter:WILEY_ML3G_TO_WILEY_ML3GV2 version:3.8.8" date="2014-01-09"></event>
<event type="xmlConverted" agent="Converter:WML3G_To_WML3G version:4.1.7 mode:FullText,remove_FC" date="2014-10-15"></event>
</eventGroup>
<numberingGroup>
<numbering type="pageFirst" number="385">385</numbering>
<numbering type="pageLast" number="388">388</numbering>
</numberingGroup>
<correspondenceTo>Royal Victorian Eye and Ear Hospital, 32 Gisborne St, East Melbourne Victoria 3002</correspondenceTo>
<linkGroup>
<link type="toTypesetVersion" href="file:CEO.CEO385.pdf"></link>
</linkGroup>
</publicationMeta>
<contentMeta>
<countGroup>
<count type="referenceTotal" number="9"></count>
<count type="linksCrossRef" number="5"></count>
</countGroup>
<titleGroup>
<title type="main">A simple snare for transscleral fixation of dislocated intraocular lenses</title>
</titleGroup>
<creators>
<creator creatorRole="author" xml:id="cr1" affiliationRef="#a1" corresponding="yes">
<personName>
<givenNames>Alex</givenNames>
<familyName>Poon</familyName>
<degrees>MB BS</degrees>
</personName>
</creator>
<creator creatorRole="author" xml:id="cr2" affiliationRef="#a1">
<personName>
<givenNames>J Ben</givenNames>
<familyName>Clark</familyName>
<degrees>FRACS, FRACO</degrees>
</personName>
</creator>
<creator creatorRole="author" xml:id="cr3" affiliationRef="#a2">
<personName>
<givenNames>Rodney HB</givenNames>
<familyName>Grey</familyName>
<degrees>FRCO</degrees>
</personName>
</creator>
<creator creatorRole="author" xml:id="cr4" affiliationRef="#a2">
<personName>
<givenNames>Richard HC</givenNames>
<familyName>Markham</familyName>
<degrees>FRCO</degrees>
</personName>
</creator>
</creators>
<affiliationGroup>
<affiliation xml:id="a1">
<unparsedAffiliation>*Geelong Hospital</unparsedAffiliation>
</affiliation>
<affiliation xml:id="a2">
<unparsedAffiliation>†Bristol Eye Hospital</unparsedAffiliation>
</affiliation>
</affiliationGroup>
<keywordGroup xml:lang="en">
<keyword xml:id="k1">Dislocation</keyword>
<keyword xml:id="k2">posterior chamber intraocular lens</keyword>
<keyword xml:id="k3">snare</keyword>
</keywordGroup>
<abstractGroup>
<abstract type="main" xml:lang="en">
<title type="main">Abstract</title>
<p>
<b>Purpose:</b>
The construction and use of a surgical snare in retrieving and securing posterior chamber intraocular lenses is described.</p>
<p>
<b>Methods:</b>
The snare consists of a 10‐0 polypropylene suture threaded into a 25‐gauge ret‐robulbar needle. This is used after a pars plana vitrectomy to retrieve the dislocated intraocular lens. The needle attached to the polypropylene suture is used to secure the lens haptic 1.5 mm behind the limbus. Two snares are used to secure the two lens haptics.</p>
<p>
<b>Conclusions:</b>
The snare is easy to make with readily available materials. The use of this snare involves less intraocular and extraocular manipulations than other described methods.</p>
</abstract>
</abstractGroup>
</contentMeta>
</header>
</component>
</istex:document>
</istex:metadataXml>
<mods version="3.6">
<titleInfo lang="en">
<title>A simple snare for transscleral fixation of dislocated intraocular lenses</title>
</titleInfo>
<titleInfo type="alternative" contentType="CDATA" lang="en">
<title>A simple snare for transscleral fixation of dislocated intraocular lenses</title>
</titleInfo>
<name type="personal">
<namePart type="given">Alex</namePart>
<namePart type="family">Poon</namePart>
<namePart type="termsOfAddress">MB BS</namePart>
<affiliation>*Geelong Hospital</affiliation>
<description>Correspondence: Royal Victorian Eye and Ear Hospital, 32 Gisborne St, East Melbourne Victoria 3002</description>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">J Ben</namePart>
<namePart type="family">Clark</namePart>
<namePart type="termsOfAddress">FRACS, FRACO</namePart>
<affiliation>*Geelong Hospital</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Rodney HB</namePart>
<namePart type="family">Grey</namePart>
<namePart type="termsOfAddress">FRCO</namePart>
<affiliation>†Bristol Eye Hospital</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Richard HC</namePart>
<namePart type="family">Markham</namePart>
<namePart type="termsOfAddress">FRCO</namePart>
<affiliation>†Bristol Eye Hospital</affiliation>
<role>
<roleTerm type="text">author</roleTerm>
</role>
</name>
<typeOfResource>text</typeOfResource>
<genre type="other" displayLabel="miscellaneous"></genre>
<originInfo>
<publisher>Blackwell Publishing Ltd</publisher>
<place>
<placeTerm type="text">Oxford, UK</placeTerm>
</place>
<dateIssued encoding="w3cdtf">1996-11</dateIssued>
<copyrightDate encoding="w3cdtf">1996</copyrightDate>
</originInfo>
<language>
<languageTerm type="code" authority="rfc3066">en</languageTerm>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<internetMediaType>text/html</internetMediaType>
<extent unit="references">9</extent>
</physicalDescription>
<abstract lang="en">Purpose:The construction and use of a surgical snare in retrieving and securing posterior chamber intraocular lenses is described. Methods:The snare consists of a 10‐0 polypropylene suture threaded into a 25‐gauge ret‐robulbar needle. This is used after a pars plana vitrectomy to retrieve the dislocated intraocular lens. The needle attached to the polypropylene suture is used to secure the lens haptic 1.5 mm behind the limbus. Two snares are used to secure the two lens haptics. Conclusions:The snare is easy to make with readily available materials. The use of this snare involves less intraocular and extraocular manipulations than other described methods.</abstract>
<subject lang="en">
<genre>keywords</genre>
<topic>Dislocation</topic>
<topic>posterior chamber intraocular lens</topic>
<topic>snare</topic>
</subject>
<relatedItem type="host">
<titleInfo>
<title>Australian and New Zealand Journal of Ophthalmology</title>
</titleInfo>
<genre type="journal">journal</genre>
<identifier type="ISSN">0814-9763</identifier>
<identifier type="eISSN">1440-1606</identifier>
<identifier type="DOI">10.1111/(ISSN)1440-1606</identifier>
<identifier type="PublisherID">CEO</identifier>
<part>
<date>1996</date>
<detail type="volume">
<caption>vol.</caption>
<number>24</number>
</detail>
<detail type="issue">
<caption>no.</caption>
<number>4</number>
</detail>
<extent unit="pages">
<start>385</start>
<end>388</end>
<total>4</total>
</extent>
</part>
</relatedItem>
<identifier type="istex">B230995F43F9136B8EB0DE12B879D81499C5A781</identifier>
<identifier type="DOI">10.1111/j.1442-9071.1996.tb01614.x</identifier>
<identifier type="ArticleID">CEO385</identifier>
<recordInfo>
<recordContentSource>WILEY</recordContentSource>
<recordOrigin>Blackwell Publishing Ltd</recordOrigin>
</recordInfo>
</mods>
</metadata>
<serie></serie>
</istex>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Istex/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000F55 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Istex/Corpus/biblio.hfd -nk 000F55 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Istex
   |étape=   Corpus
   |type=    RBID
   |clé=     ISTEX:B230995F43F9136B8EB0DE12B879D81499C5A781
   |texte=   A simple snare for transscleral fixation of dislocated intraocular lenses
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024