Noncorneal astigmatism related to poly(methyl methacrylate) and plate-haptic silicone intraocular lenses
Identifieur interne : 003B81 ( Istex/Checkpoint ); précédent : 003B80; suivant : 003B82Noncorneal astigmatism related to poly(methyl methacrylate) and plate-haptic silicone intraocular lenses
Auteurs : Detlev Spiegel ; Anton Widmann ; Richard KöllSource :
- Journal of Cataract & Refractive Surgery [ 0886-3350 ] ; 1997.
Abstract
Purpose: To evaluate noncorneal astigmatism after implantation of a one-piece, plate-haptic silicone or one-piece poly(methyl methacrylate) PMMA intraocular lens (IOL).Setting: Klinik and Poliklinik fur Augenheilkunde der Universität Regensburg, Germany.Methods: After a follow-up of at least 3 months, the degree of postoperative noncorneal astigmatism was calculated using the data from an auto refractometer. Sixty patients were evaluated: 30 with silicone IOLs (Group A) and 30 with PMMA lenses (Group B).Results: Mean noncorneal astigmatism in Group A was 0.78 diopter (D) ± 0.51 (SD), which was statistically significantly higher than that in Group B (0.51 ± 0.27 D) (P = .013). The highest noncorneal astigmatism, 2.32 D, occurred in Group A.Conclusions: Based on these findings, we recommend noncorneal astigmatism be considered in eyes with a one-piece, plate-haptic silicone IOL and postoperative astigmatism. A prospective study with a standardized capsulorhexis size is needed to ascertain whether this IOL-related noncorneal astigmatism is caused by capsular shrinkage, which may then be treatable with a laser capsulotomy of the anterior capsule.
Url:
DOI: 10.1016/S0886-3350(97)80117-4
Affiliations:
Links toward previous steps (curation, corpus...)
Links to Exploration step
ISTEX:07D98E05078D0635808AE41A6FB0EA1D49499052Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Noncorneal astigmatism related to poly(methyl methacrylate) and plate-haptic silicone intraocular lenses</title>
<author><name sortKey="Spiegel, Detlev" sort="Spiegel, Detlev" uniqKey="Spiegel D" first="Detlev" last="Spiegel">Detlev Spiegel</name>
</author>
<author><name sortKey="Widmann, Anton" sort="Widmann, Anton" uniqKey="Widmann A" first="Anton" last="Widmann">Anton Widmann</name>
</author>
<author><name sortKey="Koll, Richard" sort="Koll, Richard" uniqKey="Koll R" first="Richard" last="Köll">Richard Köll</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:07D98E05078D0635808AE41A6FB0EA1D49499052</idno>
<date when="1997" year="1997">1997</date>
<idno type="doi">10.1016/S0886-3350(97)80117-4</idno>
<idno type="url">https://api.istex.fr/document/07D98E05078D0635808AE41A6FB0EA1D49499052/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000268</idno>
<idno type="wicri:Area/Istex/Curation">000268</idno>
<idno type="wicri:Area/Istex/Checkpoint">003B81</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main" xml:lang="en">Noncorneal astigmatism related to poly(methyl methacrylate) and plate-haptic silicone intraocular lenses</title>
<author><name sortKey="Spiegel, Detlev" sort="Spiegel, Detlev" uniqKey="Spiegel D" first="Detlev" last="Spiegel">Detlev Spiegel</name>
</author>
<author><name sortKey="Widmann, Anton" sort="Widmann, Anton" uniqKey="Widmann A" first="Anton" last="Widmann">Anton Widmann</name>
</author>
<author><name sortKey="Koll, Richard" sort="Koll, Richard" uniqKey="Koll R" first="Richard" last="Köll">Richard Köll</name>
</author>
</analytic>
<monogr></monogr>
<series><title level="j">Journal of Cataract & Refractive Surgery</title>
<title level="j" type="abbrev">JCRS</title>
<idno type="ISSN">0886-3350</idno>
<imprint><publisher>ELSEVIER</publisher>
<date type="published" when="1997">1997</date>
<biblScope unit="volume">23</biblScope>
<biblScope unit="issue">9</biblScope>
<biblScope unit="page" from="1376">1376</biblScope>
<biblScope unit="page" to="1379">1379</biblScope>
</imprint>
<idno type="ISSN">0886-3350</idno>
</series>
<idno type="istex">07D98E05078D0635808AE41A6FB0EA1D49499052</idno>
<idno type="DOI">10.1016/S0886-3350(97)80117-4</idno>
<idno type="PII">S0886-3350(97)80117-4</idno>
<idno type="ArticleID">80117</idno>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0886-3350</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass></textClass>
<langUsage><language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Purpose: To evaluate noncorneal astigmatism after implantation of a one-piece, plate-haptic silicone or one-piece poly(methyl methacrylate) PMMA intraocular lens (IOL).Setting: Klinik and Poliklinik fur Augenheilkunde der Universität Regensburg, Germany.Methods: After a follow-up of at least 3 months, the degree of postoperative noncorneal astigmatism was calculated using the data from an auto refractometer. Sixty patients were evaluated: 30 with silicone IOLs (Group A) and 30 with PMMA lenses (Group B).Results: Mean noncorneal astigmatism in Group A was 0.78 diopter (D) ± 0.51 (SD), which was statistically significantly higher than that in Group B (0.51 ± 0.27 D) (P = .013). The highest noncorneal astigmatism, 2.32 D, occurred in Group A.Conclusions: Based on these findings, we recommend noncorneal astigmatism be considered in eyes with a one-piece, plate-haptic silicone IOL and postoperative astigmatism. A prospective study with a standardized capsulorhexis size is needed to ascertain whether this IOL-related noncorneal astigmatism is caused by capsular shrinkage, which may then be treatable with a laser capsulotomy of the anterior capsule.</div>
</front>
</TEI>
<affiliations><list></list>
<tree><noCountry><name sortKey="Koll, Richard" sort="Koll, Richard" uniqKey="Koll R" first="Richard" last="Köll">Richard Köll</name>
<name sortKey="Spiegel, Detlev" sort="Spiegel, Detlev" uniqKey="Spiegel D" first="Detlev" last="Spiegel">Detlev Spiegel</name>
<name sortKey="Widmann, Anton" sort="Widmann, Anton" uniqKey="Widmann A" first="Anton" last="Widmann">Anton Widmann</name>
</noCountry>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Istex/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003B81 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Istex/Checkpoint/biblio.hfd -nk 003B81 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Ticri/CIDE |area= HapticV1 |flux= Istex |étape= Checkpoint |type= RBID |clé= ISTEX:07D98E05078D0635808AE41A6FB0EA1D49499052 |texte= Noncorneal astigmatism related to poly(methyl methacrylate) and plate-haptic silicone intraocular lenses }}
This area was generated with Dilib version V0.6.23. |