Silicone and poly(methyl methacrylate) lens decentration associated with asymmetric capsule shrinkage in rabbits

Identifieur interne : 003434 ( Istex/Checkpoint ); précédent : 003433; suivant : 003435

Silicone and poly(methyl methacrylate) lens decentration associated with asymmetric capsule shrinkage in rabbits

Auteurs : Shunsaku Ohmi [Japon] ; Saiichi Tanaka [Japon] ; Shizuyz Saika [Japon] ; Yoshitaka Ohnishi [Japon]

Source :

RBID : ISTEX:5F3476851973AF2581FCB3BE425FE79818FE235D

Abstract

Purpose To determine whether silicone intraocular lenses (IOLs) are readily affected by capsule shrinkage.Setting Department of Ophthalmology, Wakayama Medical College, Wakayama, Japan.Methods A D-shaped incision was made in the anterior capsule of 38 eyes of 20 white rabbits. One of 2 IOL types was implanted in the capsular bag: 3-piece silicone or single-piece all-poly(methyl methacrylate) (PMMA). Twenty-eight eyes were evaluated for IOL rotation and optic decentration.Results The extent of postoperative decentration and rotation observed with the silicone IOLs did not significantly exceed that of the PMMA IOLs.Conclusions Our results, coupled with the advantages of small incision surgery, indicate that a silicone IOL is an effective choice.

Url:
DOI: 10.1016/S0886-3350(99)00140-6


Affiliations:


Links toward previous steps (curation, corpus...)


Links to Exploration step

ISTEX:5F3476851973AF2581FCB3BE425FE79818FE235D

Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Silicone and poly(methyl methacrylate) lens decentration associated with asymmetric capsule shrinkage in rabbits</title>
<author>
<name sortKey="Ohmi, Shunsaku" sort="Ohmi, Shunsaku" uniqKey="Ohmi S" first="Shunsaku" last="Ohmi">Shunsaku Ohmi</name>
</author>
<author>
<name sortKey="Tanaka, Saiichi" sort="Tanaka, Saiichi" uniqKey="Tanaka S" first="Saiichi" last="Tanaka">Saiichi Tanaka</name>
</author>
<author>
<name sortKey="Saika, Shizuyz" sort="Saika, Shizuyz" uniqKey="Saika S" first="Shizuyz" last="Saika">Shizuyz Saika</name>
</author>
<author>
<name sortKey="Ohnishi, Yoshitaka" sort="Ohnishi, Yoshitaka" uniqKey="Ohnishi Y" first="Yoshitaka" last="Ohnishi">Yoshitaka Ohnishi</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:5F3476851973AF2581FCB3BE425FE79818FE235D</idno>
<date when="1999" year="1999">1999</date>
<idno type="doi">10.1016/S0886-3350(99)00140-6</idno>
<idno type="url">https://api.istex.fr/document/5F3476851973AF2581FCB3BE425FE79818FE235D/fulltext/pdf</idno>
<idno type="wicri:Area/Istex/Corpus">004584</idno>
<idno type="wicri:Area/Istex/Curation">004584</idno>
<idno type="wicri:Area/Istex/Checkpoint">003434</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Silicone and poly(methyl methacrylate) lens decentration associated with asymmetric capsule shrinkage in rabbits</title>
<author>
<name sortKey="Ohmi, Shunsaku" sort="Ohmi, Shunsaku" uniqKey="Ohmi S" first="Shunsaku" last="Ohmi">Shunsaku Ohmi</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Ohmi Eye Clinic, Sakai (Ohmi)</wicri:regionArea>
<wicri:noRegion>Sakai (Ohmi)</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Tanaka, Saiichi" sort="Tanaka, Saiichi" uniqKey="Tanaka S" first="Saiichi" last="Tanaka">Saiichi Tanaka</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Department of Ophthalmology, Wakayama Medical College, Wakayama (Ohmi, Tanaka, Saika, Ohnishi)</wicri:regionArea>
<wicri:noRegion>Ohnishi)</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Saika, Shizuyz" sort="Saika, Shizuyz" uniqKey="Saika S" first="Shizuyz" last="Saika">Shizuyz Saika</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Department of Ophthalmology, Wakayama Medical College, Wakayama (Ohmi, Tanaka, Saika, Ohnishi)</wicri:regionArea>
<wicri:noRegion>Ohnishi)</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="Ohnishi, Yoshitaka" sort="Ohnishi, Yoshitaka" uniqKey="Ohnishi Y" first="Yoshitaka" last="Ohnishi">Yoshitaka Ohnishi</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Japon</country>
<wicri:regionArea>Department of Ophthalmology, Wakayama Medical College, Wakayama (Ohmi, Tanaka, Saika, Ohnishi)</wicri:regionArea>
<wicri:noRegion>Ohnishi)</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Journal of Cataract & Refractive Surgery</title>
<title level="j" type="abbrev">JCRS</title>
<idno type="ISSN">0886-3350</idno>
<imprint>
<publisher>ELSEVIER</publisher>
<date type="published" when="1999">1999</date>
<biblScope unit="volume">25</biblScope>
<biblScope unit="issue">8</biblScope>
<biblScope unit="page" from="1147">1147</biblScope>
<biblScope unit="page" to="1150">1150</biblScope>
</imprint>
<idno type="ISSN">0886-3350</idno>
</series>
<idno type="istex">5F3476851973AF2581FCB3BE425FE79818FE235D</idno>
<idno type="DOI">10.1016/S0886-3350(99)00140-6</idno>
<idno type="PII">S0886-3350(99)00140-6</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0886-3350</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Purpose To determine whether silicone intraocular lenses (IOLs) are readily affected by capsule shrinkage.Setting Department of Ophthalmology, Wakayama Medical College, Wakayama, Japan.Methods A D-shaped incision was made in the anterior capsule of 38 eyes of 20 white rabbits. One of 2 IOL types was implanted in the capsular bag: 3-piece silicone or single-piece all-poly(methyl methacrylate) (PMMA). Twenty-eight eyes were evaluated for IOL rotation and optic decentration.Results The extent of postoperative decentration and rotation observed with the silicone IOLs did not significantly exceed that of the PMMA IOLs.Conclusions Our results, coupled with the advantages of small incision surgery, indicate that a silicone IOL is an effective choice.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Japon</li>
</country>
</list>
<tree>
<country name="Japon">
<noRegion>
<name sortKey="Ohmi, Shunsaku" sort="Ohmi, Shunsaku" uniqKey="Ohmi S" first="Shunsaku" last="Ohmi">Shunsaku Ohmi</name>
</noRegion>
<name sortKey="Ohnishi, Yoshitaka" sort="Ohnishi, Yoshitaka" uniqKey="Ohnishi Y" first="Yoshitaka" last="Ohnishi">Yoshitaka Ohnishi</name>
<name sortKey="Saika, Shizuyz" sort="Saika, Shizuyz" uniqKey="Saika S" first="Shizuyz" last="Saika">Shizuyz Saika</name>
<name sortKey="Tanaka, Saiichi" sort="Tanaka, Saiichi" uniqKey="Tanaka S" first="Saiichi" last="Tanaka">Saiichi Tanaka</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Ticri/CIDE/explor/HapticV1/Data/Istex/Checkpoint
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003434 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Istex/Checkpoint/biblio.hfd -nk 003434 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Ticri/CIDE
   |area=    HapticV1
   |flux=    Istex
   |étape=   Checkpoint
   |type=    RBID
   |clé=     ISTEX:5F3476851973AF2581FCB3BE425FE79818FE235D
   |texte=   Silicone and poly(methyl methacrylate) lens decentration associated with asymmetric capsule shrinkage in rabbits
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Mon Jun 13 01:09:46 2016. Site generation: Wed Mar 6 09:54:07 2024