The objective of this study was to determine the absorbed radiation doses to various structures within the head and neck as a result of routine mandibular and maxillary occlusal radiography. Five projections were investigated: the anterior mandibular; true mandibular; anterior maxillary; lateral maxillary; and maxillary vertex occlusal radiographic views. Standard thermoluminescent dosimetry methodology was employed using a humanoid phantom of the skull. Multiple exposures were done for each view to ensure adequate precision. The absorbed doses to various locations following a single occlusal exposure are presented in centiGray (cGy). It was found that the absorbed dose values for occlusal radiography observed in this study were similar in magnitude to previously reported absorbed dose values for other forms of dental radiography. Values ranged from 0.0014 cGy to 1.301 cGy. The highest absorbed doses were generally the skin entrance doses. The results of this study provide an accurate, concise summary of surface and internal absorbed radiation doses for five commonly used occlusal radiographs. They can be used in the calculation of risk estimates for dental radiography, and may assist dentists in their discussions with patients concerned about radiation exposure.

PubMed: 8521323


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Surface and internal absorbed doses in mandibular and maxillary occlusal radiography.</title>
<author>
<name sortKey="Roth, S F" sort="Roth, S F" uniqKey="Roth S" first="S F" last="Roth">S F Roth</name>
<affiliation wicri:level="3">
<nlm:affiliation>University of Western Ontario, London.</nlm:affiliation>
<country>Royaume-Uni</country>
<placeName>
<settlement type="city">Londres</settlement>
<region type="country">Angleterre</region>
<region type="région" nuts="1">Grand Londres</region>
</placeName>
<wicri:orgArea>University of Western Ontario</wicri:orgArea>
</affiliation>
</author>
<author>
<name sortKey="Bohay, R N" sort="Bohay, R N" uniqKey="Bohay R" first="R N" last="Bohay">R N Bohay</name>
</author>
<author>
<name sortKey="Barnett, R B" sort="Barnett, R B" uniqKey="Barnett R" first="R B" last="Barnett">R B Barnett</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1995">1995</date>
<idno type="RBID">pubmed:8521323</idno>
<idno type="pmid">8521323</idno>
<idno type="wicri:Area/Main/Corpus">000601</idno>
<idno type="wicri:explorRef" wicri:stream="Main" wicri:step="Corpus" wicri:corpus="PubMed">000601</idno>
<idno type="wicri:Area/Main/Curation">000601</idno>
<idno type="wicri:explorRef" wicri:stream="Main" wicri:step="Curation">000601</idno>
<idno type="wicri:Area/Main/Exploration">000601</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">Surface and internal absorbed doses in mandibular and maxillary occlusal radiography.</title>
<author>
<name sortKey="Roth, S F" sort="Roth, S F" uniqKey="Roth S" first="S F" last="Roth">S F Roth</name>
<affiliation wicri:level="3">
<nlm:affiliation>University of Western Ontario, London.</nlm:affiliation>
<country>Royaume-Uni</country>
<placeName>
<settlement type="city">Londres</settlement>
<region type="country">Angleterre</region>
<region type="région" nuts="1">Grand Londres</region>
</placeName>
<wicri:orgArea>University of Western Ontario</wicri:orgArea>
</affiliation>
</author>
<author>
<name sortKey="Bohay, R N" sort="Bohay, R N" uniqKey="Bohay R" first="R N" last="Bohay">R N Bohay</name>
</author>
<author>
<name sortKey="Barnett, R B" sort="Barnett, R B" uniqKey="Barnett R" first="R B" last="Barnett">R B Barnett</name>
</author>
</analytic>
<series>
<title level="j">Journal (Canadian Dental Association)</title>
<idno type="ISSN">0709-8936</idno>
<imprint>
<date when="1995" type="published">1995</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Absorption (MeSH)</term>
<term>Humans (MeSH)</term>
<term>Jaw (diagnostic imaging)</term>
<term>Jaw Relation Record (methods)</term>
<term>Phantoms, Imaging (MeSH)</term>
<term>Radiation Dosage (MeSH)</term>
<term>Radiography (MeSH)</term>
<term>Thermoluminescent Dosimetry (MeSH)</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Absorption (MeSH)</term>
<term>Dose de rayonnement (MeSH)</term>
<term>Dosimétrie par thermoluminescence (MeSH)</term>
<term>Enregistrement des rapports intermaxillaires (méthodes)</term>
<term>Fantômes en imagerie (MeSH)</term>
<term>Humains (MeSH)</term>
<term>Mâchoire (imagerie diagnostique)</term>
<term>Radiographie (MeSH)</term>
</keywords>
<keywords scheme="MESH" qualifier="diagnostic imaging" xml:lang="en">
<term>Jaw</term>
</keywords>
<keywords scheme="MESH" qualifier="imagerie diagnostique" xml:lang="fr">
<term>Mâchoire</term>
</keywords>
<keywords scheme="MESH" qualifier="methods" xml:lang="en">
<term>Jaw Relation Record</term>
</keywords>
<keywords scheme="MESH" qualifier="méthodes" xml:lang="fr">
<term>Enregistrement des rapports intermaxillaires</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Absorption</term>
<term>Humans</term>
<term>Phantoms, Imaging</term>
<term>Radiation Dosage</term>
<term>Radiography</term>
<term>Thermoluminescent Dosimetry</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Absorption</term>
<term>Dose de rayonnement</term>
<term>Dosimétrie par thermoluminescence</term>
<term>Fantômes en imagerie</term>
<term>Humains</term>
<term>Radiographie</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The objective of this study was to determine the absorbed radiation doses to various structures within the head and neck as a result of routine mandibular and maxillary occlusal radiography. Five projections were investigated: the anterior mandibular; true mandibular; anterior maxillary; lateral maxillary; and maxillary vertex occlusal radiographic views. Standard thermoluminescent dosimetry methodology was employed using a humanoid phantom of the skull. Multiple exposures were done for each view to ensure adequate precision. The absorbed doses to various locations following a single occlusal exposure are presented in centiGray (cGy). It was found that the absorbed dose values for occlusal radiography observed in this study were similar in magnitude to previously reported absorbed dose values for other forms of dental radiography. Values ranged from 0.0014 cGy to 1.301 cGy. The highest absorbed doses were generally the skin entrance doses. The results of this study provide an accurate, concise summary of surface and internal absorbed radiation doses for five commonly used occlusal radiographs. They can be used in the calculation of risk estimates for dental radiography, and may assist dentists in their discussions with patients concerned about radiation exposure.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">8521323</PMID>
<DateCompleted>
<Year>1996</Year>
<Month>01</Month>
<Day>19</Day>
</DateCompleted>
<DateRevised>
<Year>2016</Year>
<Month>11</Month>
<Day>23</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0709-8936</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>61</Volume>
<Issue>11</Issue>
<PubDate>
<Year>1995</Year>
<Month>Nov</Month>
</PubDate>
</JournalIssue>
<Title>Journal (Canadian Dental Association)</Title>
<ISOAbbreviation>J Can Dent Assoc</ISOAbbreviation>
</Journal>
<ArticleTitle>Surface and internal absorbed doses in mandibular and maxillary occlusal radiography.</ArticleTitle>
<Pagination>
<MedlinePgn>955-9</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>The objective of this study was to determine the absorbed radiation doses to various structures within the head and neck as a result of routine mandibular and maxillary occlusal radiography. Five projections were investigated: the anterior mandibular; true mandibular; anterior maxillary; lateral maxillary; and maxillary vertex occlusal radiographic views. Standard thermoluminescent dosimetry methodology was employed using a humanoid phantom of the skull. Multiple exposures were done for each view to ensure adequate precision. The absorbed doses to various locations following a single occlusal exposure are presented in centiGray (cGy). It was found that the absorbed dose values for occlusal radiography observed in this study were similar in magnitude to previously reported absorbed dose values for other forms of dental radiography. Values ranged from 0.0014 cGy to 1.301 cGy. The highest absorbed doses were generally the skin entrance doses. The results of this study provide an accurate, concise summary of surface and internal absorbed radiation doses for five commonly used occlusal radiographs. They can be used in the calculation of risk estimates for dental radiography, and may assist dentists in their discussions with patients concerned about radiation exposure.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Roth</LastName>
<ForeName>S F</ForeName>
<Initials>SF</Initials>
<AffiliationInfo>
<Affiliation>University of Western Ontario, London.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Bohay</LastName>
<ForeName>R N</ForeName>
<Initials>RN</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Barnett</LastName>
<ForeName>R B</ForeName>
<Initials>RB</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>Canada</Country>
<MedlineTA>J Can Dent Assoc</MedlineTA>
<NlmUniqueID>7907605</NlmUniqueID>
<ISSNLinking>0709-8936</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>D</CitationSubset>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000042" MajorTopicYN="N">Absorption</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007568" MajorTopicYN="N">Jaw</DescriptorName>
<QualifierName UI="Q000000981" MajorTopicYN="Y">diagnostic imaging</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007574" MajorTopicYN="N">Jaw Relation Record</DescriptorName>
<QualifierName UI="Q000379" MajorTopicYN="N">methods</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D019047" MajorTopicYN="N">Phantoms, Imaging</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011829" MajorTopicYN="N">Radiation Dosage</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D011859" MajorTopicYN="N">Radiography</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013819" MajorTopicYN="N">Thermoluminescent Dosimetry</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1995</Year>
<Month>11</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1995</Year>
<Month>11</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1995</Year>
<Month>11</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">8521323</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>Royaume-Uni</li>
</country>
<region>
<li>Angleterre</li>
<li>Grand Londres</li>
</region>
<settlement>
<li>Londres</li>
</settlement>
</list>
<tree>
<noCountry>
<name sortKey="Barnett, R B" sort="Barnett, R B" uniqKey="Barnett R" first="R B" last="Barnett">R B Barnett</name>
<name sortKey="Bohay, R N" sort="Bohay, R N" uniqKey="Bohay R" first="R N" last="Bohay">R N Bohay</name>
</noCountry>
<country name="Royaume-Uni">
<region name="Angleterre">
<name sortKey="Roth, S F" sort="Roth, S F" uniqKey="Roth S" first="S F" last="Roth">S F Roth</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Sante/explor/SuicidDentistV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000598 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000598 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Sante
   |area=    SuicidDentistV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:8521323
   |texte=   Surface and internal absorbed doses in mandibular and maxillary occlusal radiography.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:8521323" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a SuicidDentistV1 

Wicri

This area was generated with Dilib version V0.6.39.
Data generation: Sun Oct 3 17:04:29 2021. Site generation: Sun Oct 3 17:05:17 2021