Serveur d'exploration Stress et Covid

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

The efficacy and acceptability of using a jet injector in performing digital blocks

Identifieur interne : 003357 ( Main/Exploration ); précédent : 003356; suivant : 003358

The efficacy and acceptability of using a jet injector in performing digital blocks

Auteurs : George L. Ellis [États-Unis] ; Ada Owens [États-Unis]

Source :

RBID : ISTEX:222744DB0CCFC2A5F6EBDA388002B1A042210BA3

English descriptors

Abstract

Abstract: This prospective, nonblinded study, comparing jet injection with needlesyringe injection of lidocaine in performing digital blocks, tested the hypothesis that jet injection can be used effectively as a less painful way to perform digital blocks. Twenty-four adult patients with injuries of the middle or distal phalanges of the fingers received digital blocks using a jet injector on one side of the finger and a needle-syringe on the other side; pain was assessed at 0, 1, 3, 6, 12, and 24 hours using visual analog scales. Differences in pain scores for the two procedures (jet injector vs needle) were tested at each time period using nonparametric statistical procedures for paired or matched data (paired Wilcoxon). At the time of injection (time 0) and at 12 hours, the jet had a significantly lower pain score than the needle. Comparisons made at the other points were statistically nonsignificant at .05. The anesthesia achieved using the jet injector was considered adequate in 23 of 24 patients. We conclude that the jet injector can be used effectively in performing digital blocks and is less painful than standard needle-syringe methods.

Url:
DOI: 10.1016/0735-6757(93)90024-6


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title>The efficacy and acceptability of using a jet injector in performing digital blocks</title>
<author>
<name sortKey="Ellis, George L" sort="Ellis, George L" uniqKey="Ellis G" first="George L." last="Ellis">George L. Ellis</name>
</author>
<author>
<name sortKey="Owens, Ada" sort="Owens, Ada" uniqKey="Owens A" first="Ada" last="Owens">Ada Owens</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:222744DB0CCFC2A5F6EBDA388002B1A042210BA3</idno>
<date when="1993" year="1993">1993</date>
<idno type="doi">10.1016/0735-6757(93)90024-6</idno>
<idno type="url">https://api.istex.fr/ark:/67375/6H6-V7PKC30N-H/fulltext.pdf</idno>
<idno type="wicri:Area/Istex/Corpus">001299</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">001299</idno>
<idno type="wicri:Area/Istex/Curation">001239</idno>
<idno type="wicri:Area/Istex/Checkpoint">001B98</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">001B98</idno>
<idno type="wicri:doubleKey">0735-6757:1993:Ellis G:the:efficacy:and</idno>
<idno type="wicri:Area/Main/Merge">003371</idno>
<idno type="wicri:Area/Main/Curation">003357</idno>
<idno type="wicri:Area/Main/Exploration">003357</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a">The efficacy and acceptability of using a jet injector in performing digital blocks</title>
<author>
<name sortKey="Ellis, George L" sort="Ellis, George L" uniqKey="Ellis G" first="George L." last="Ellis">George L. Ellis</name>
<affiliation wicri:level="2">
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Emergency Medicine, Guthrie Clinic/Robert Packer Hospital, Sayre, PA</wicri:regionArea>
<placeName>
<region type="state">Pennsylvanie</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Owens, Ada" sort="Owens, Ada" uniqKey="Owens A" first="Ada" last="Owens">Ada Owens</name>
<affiliation wicri:level="4">
<country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Biostatistics, Graduate School of Public Health, University of Pittsburgh, Pittsburgh, PA</wicri:regionArea>
<placeName>
<region type="state">Pennsylvanie</region>
<settlement type="city">Pittsburgh</settlement>
</placeName>
<orgName type="university">Université de Pittsburgh</orgName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">American Journal of Emergency Medicine</title>
<title level="j" type="abbrev">YAJEM</title>
<idno type="ISSN">0735-6757</idno>
<imprint>
<publisher>ELSEVIER</publisher>
<date type="published" when="1993">1993</date>
<biblScope unit="volume">11</biblScope>
<biblScope unit="issue">6</biblScope>
<biblScope unit="page" from="648">648</biblScope>
<biblScope unit="page" to="650">650</biblScope>
</imprint>
<idno type="ISSN">0735-6757</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0735-6757</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="Teeft" xml:lang="en">
<term>Adequate anesthesia</term>
<term>Anesthesia</term>
<term>Anesthetic</term>
<term>Cherry hill</term>
<term>Current study</term>
<term>Digital blocks</term>
<term>Distal phalanges</term>
<term>Emergency medicine</term>
<term>Emergency medicine literature</term>
<term>Injection</term>
<term>Injection site</term>
<term>Injector</term>
<term>Laceration</term>
<term>Lidocaine</term>
<term>Median</term>
<term>Median pain scores</term>
<term>Metacarpal head</term>
<term>Nonblinded study</term>
<term>Nonparametric</term>
<term>Other side</term>
<term>Overall results</term>
<term>Pain score</term>
<term>Pain scores</term>
<term>Proximal phalanx</term>
<term>Radial aspect</term>
<term>Saunders company</term>
<term>Second injection</term>
<term>Significant differences</term>
<term>Syringe</term>
<term>Time period</term>
<term>Total volume</term>
<term>Visual analog scales</term>
</keywords>
</textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Abstract: This prospective, nonblinded study, comparing jet injection with needlesyringe injection of lidocaine in performing digital blocks, tested the hypothesis that jet injection can be used effectively as a less painful way to perform digital blocks. Twenty-four adult patients with injuries of the middle or distal phalanges of the fingers received digital blocks using a jet injector on one side of the finger and a needle-syringe on the other side; pain was assessed at 0, 1, 3, 6, 12, and 24 hours using visual analog scales. Differences in pain scores for the two procedures (jet injector vs needle) were tested at each time period using nonparametric statistical procedures for paired or matched data (paired Wilcoxon). At the time of injection (time 0) and at 12 hours, the jet had a significantly lower pain score than the needle. Comparisons made at the other points were statistically nonsignificant at .05. The anesthesia achieved using the jet injector was considered adequate in 23 of 24 patients. We conclude that the jet injector can be used effectively in performing digital blocks and is less painful than standard needle-syringe methods.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>États-Unis</li>
</country>
<region>
<li>Pennsylvanie</li>
</region>
<settlement>
<li>Pittsburgh</li>
</settlement>
<orgName>
<li>Université de Pittsburgh</li>
</orgName>
</list>
<tree>
<country name="États-Unis">
<region name="Pennsylvanie">
<name sortKey="Ellis, George L" sort="Ellis, George L" uniqKey="Ellis G" first="George L." last="Ellis">George L. Ellis</name>
</region>
<name sortKey="Owens, Ada" sort="Owens, Ada" uniqKey="Owens A" first="Ada" last="Owens">Ada Owens</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Sante/explor/StressCovidV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003357 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 003357 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Sante
   |area=    StressCovidV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:222744DB0CCFC2A5F6EBDA388002B1A042210BA3
   |texte=   The efficacy and acceptability of using a jet injector in performing digital blocks
}}

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Wed May 6 16:44:09 2020. Site generation: Sun Mar 28 08:26:57 2021