Pathogen cross-transmission via building sanitary plumbing systems in a full scale pilot test-rig

Identifieur interne : 001352 ( Pmc/Corpus ); précédent : 001351; suivant : 001353

Pathogen cross-transmission via building sanitary plumbing systems in a full scale pilot test-rig

Auteurs : Michael Gormley ; Thomas J. Aspray ; David A. Kelly ; Cristina Rodriguez-Gil

Source :

RBID : PMC:5302810

Abstract

The WHO Consensus Document on the epidemiology of the SARS epidemic in 2003, included a report on a concentrated outbreak in one Hong Kong housing block which was considered a ‘super-spreading event’. The WHO report conjectured that the sanitary plumbing system was one transmission route for the virus. Empty U-traps allowed the aerosolised virus to enter households from the sewerage system. No biological evidence was presented. This research reports evidence that pathogens can be aerosolised and transported on airstreams within sanitary plumbing systems and enter buildings via empty U-traps. A sanitary plumbing system was built, representing two floors of a building, with simulated toilet flushes on the lower floor and a sterile chamber with extractor fan on the floor above. Cultures of a model organism, Pseudomonas putida at 106–109 cfu ml-1 in 0·85% NaCl were flushed into the system in volumes of 6 to 20 litres to represent single or multiple toilet flushes. Air and surface samples were cultured on agar plates and assessed qualitatively and semi-quantitatively. Flushing from a toilet into a sanitary plumbing system generated enough turbulence to aerosolise pathogens. Typical sanitary plumbing system airflows (between 20–30 ls-1) were sufficient to carry aerosolised pathogens between different floors of a building. Empty U-traps allowed aerosolised pathogens to enter the chamber, encouraging cross-transmission. All parts of the system were found to be contaminated post-flush. Empty U-traps have been observed in many buildings and a risk assessment indicates the potential for high risk cross-transmission under defect conditions in buildings with high pathogen loading such as hospitals. Under defective conditions (which are not uncommon) aerosolised pathogens can be carried on the airflows within sanitary plumbing systems. Our findings show that greater consideration should be given to this mode of pathogen transmission.


Url:
DOI: 10.1371/journal.pone.0171556
PubMed: 28187135
PubMed Central: 5302810

Links to Exploration step

PMC:5302810

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Pathogen cross-transmission via building sanitary plumbing systems in a full scale pilot test-rig</title>
<author>
<name sortKey="Gormley, Michael" sort="Gormley, Michael" uniqKey="Gormley M" first="Michael" last="Gormley">Michael Gormley</name>
<affiliation>
<nlm:aff id="aff001"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Aspray, Thomas J" sort="Aspray, Thomas J" uniqKey="Aspray T" first="Thomas J." last="Aspray">Thomas J. Aspray</name>
<affiliation>
<nlm:aff id="aff001"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Kelly, David A" sort="Kelly, David A" uniqKey="Kelly D" first="David A." last="Kelly">David A. Kelly</name>
<affiliation>
<nlm:aff id="aff001"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Rodriguez Gil, Cristina" sort="Rodriguez Gil, Cristina" uniqKey="Rodriguez Gil C" first="Cristina" last="Rodriguez-Gil">Cristina Rodriguez-Gil</name>
<affiliation>
<nlm:aff id="aff001"></nlm:aff>
</affiliation>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">28187135</idno>
<idno type="pmc">5302810</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5302810</idno>
<idno type="RBID">PMC:5302810</idno>
<idno type="doi">10.1371/journal.pone.0171556</idno>
<date when="2017">2017</date>
<idno type="wicri:Area/Pmc/Corpus">001352</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">001352</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Pathogen cross-transmission via building sanitary plumbing systems in a full scale pilot test-rig</title>
<author>
<name sortKey="Gormley, Michael" sort="Gormley, Michael" uniqKey="Gormley M" first="Michael" last="Gormley">Michael Gormley</name>
<affiliation>
<nlm:aff id="aff001"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Aspray, Thomas J" sort="Aspray, Thomas J" uniqKey="Aspray T" first="Thomas J." last="Aspray">Thomas J. Aspray</name>
<affiliation>
<nlm:aff id="aff001"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Kelly, David A" sort="Kelly, David A" uniqKey="Kelly D" first="David A." last="Kelly">David A. Kelly</name>
<affiliation>
<nlm:aff id="aff001"></nlm:aff>
</affiliation>
</author>
<author>
<name sortKey="Rodriguez Gil, Cristina" sort="Rodriguez Gil, Cristina" uniqKey="Rodriguez Gil C" first="Cristina" last="Rodriguez-Gil">Cristina Rodriguez-Gil</name>
<affiliation>
<nlm:aff id="aff001"></nlm:aff>
</affiliation>
</author>
</analytic>
<series>
<title level="j">PLoS ONE</title>
<idno type="eISSN">1932-6203</idno>
<imprint>
<date when="2017">2017</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p>The WHO Consensus Document on the epidemiology of the SARS epidemic in 2003, included a report on a concentrated outbreak in one Hong Kong housing block which was considered a ‘super-spreading event’. The WHO report conjectured that the sanitary plumbing system was one transmission route for the virus. Empty U-traps allowed the aerosolised virus to enter households from the sewerage system. No biological evidence was presented. This research reports evidence that pathogens can be aerosolised and transported on airstreams within sanitary plumbing systems and enter buildings via empty U-traps. A sanitary plumbing system was built, representing two floors of a building, with simulated toilet flushes on the lower floor and a sterile chamber with extractor fan on the floor above. Cultures of a model organism,
<italic>Pseudomonas putida</italic>
at 10
<sup>6</sup>
–10
<sup>9</sup>
cfu ml
<sup>-1</sup>
in 0·85% NaCl were flushed into the system in volumes of 6 to 20 litres to represent single or multiple toilet flushes. Air and surface samples were cultured on agar plates and assessed qualitatively and semi-quantitatively. Flushing from a toilet into a sanitary plumbing system generated enough turbulence to aerosolise pathogens. Typical sanitary plumbing system airflows (between 20–30 ls
<sup>-1</sup>
) were sufficient to carry aerosolised pathogens between different floors of a building. Empty U-traps allowed aerosolised pathogens to enter the chamber, encouraging cross-transmission. All parts of the system were found to be contaminated post-flush. Empty U-traps have been observed in many buildings and a risk assessment indicates the potential for high risk cross-transmission under defect conditions in buildings with high pathogen loading such as hospitals. Under defective conditions (which are not uncommon) aerosolised pathogens can be carried on the airflows within sanitary plumbing systems. Our findings show that greater consideration should be given to this mode of pathogen transmission.</p>
</div>
</front>
<back>
<div1 type="bibliography">
<listBibl>
<biblStruct>
<analytic>
<author>
<name sortKey="Moore, G" uniqKey="Moore G">G Moore</name>
</author>
<author>
<name sortKey="Walker, Jt" uniqKey="Walker J">JT Walker</name>
</author>
<author>
<name sortKey="Percival, Sl" uniqKey="Percival S">SL Percival</name>
</author>
<author>
<name sortKey="Randle, J" uniqKey="Randle J">J Randle</name>
</author>
<author>
<name sortKey="Cooper, T" uniqKey="Cooper T">T Cooper</name>
</author>
<author>
<name sortKey="Williams, D" uniqKey="Williams D">D Williams</name>
</author>
</analytic>
</biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Moore, G" uniqKey="Moore G">G Moore</name>
</author>
<author>
<name sortKey="Stevenson, D" uniqKey="Stevenson D">D Stevenson</name>
</author>
<author>
<name sortKey="Thompson, K A" uniqKey="Thompson K">K-A Thompson</name>
</author>
<author>
<name sortKey="Parks, S" uniqKey="Parks S">S Parks</name>
</author>
<author>
<name sortKey="Ngabo, D" uniqKey="Ngabo D">D Ngabo</name>
</author>
<author>
<name sortKey="Bennett, Am" uniqKey="Bennett A">AM Bennett</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Walker, Jt" uniqKey="Walker J">JT Walker</name>
</author>
<author>
<name sortKey="Moore, G" uniqKey="Moore G">G. Moore</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Pitts, B" uniqKey="Pitts B">B Pitts</name>
</author>
<author>
<name sortKey="Stewart, Ps" uniqKey="Stewart P">PS Stewart</name>
</author>
<author>
<name sortKey="Mcfeters, Ga" uniqKey="Mcfeters G">GA McFeters</name>
</author>
<author>
<name sortKey="Hamilton, Ma" uniqKey="Hamilton M">MA Hamilton</name>
</author>
<author>
<name sortKey="Willse, A" uniqKey="Willse A">A Willse</name>
</author>
<author>
<name sortKey="Zelver, N" uniqKey="Zelver N">N Zelver</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Gebra, Cp" uniqKey="Gebra C">CP Gebra</name>
</author>
<author>
<name sortKey="Wallis, C" uniqKey="Wallis C">C Wallis</name>
</author>
<author>
<name sortKey="Melnick, Jl" uniqKey="Melnick J">JL Melnick</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Barker, J" uniqKey="Barker J">J Barker</name>
</author>
<author>
<name sortKey="Jones, Mv" uniqKey="Jones M">MV Jones</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Barker, J" uniqKey="Barker J">J Barker</name>
</author>
<author>
<name sortKey="Bloomfield, S" uniqKey="Bloomfield S">S. Bloomfield</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Riley, S" uniqKey="Riley S">S Riley</name>
</author>
<author>
<name sortKey="Fraser, C" uniqKey="Fraser C">C Fraser</name>
</author>
<author>
<name sortKey="Donnelly, Ca" uniqKey="Donnelly C">CA Donnelly</name>
</author>
<author>
<name sortKey="Ghani, Ac" uniqKey="Ghani A">AC Ghani</name>
</author>
<author>
<name sortKey="Abu Radda, Lj" uniqKey="Abu Radda L">LJ Abu-Radda</name>
</author>
<author>
<name sortKey="Hedley, Aj" uniqKey="Hedley A">AJ Hedley</name>
</author>
</analytic>
</biblStruct>
<biblStruct></biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Tang, Jw" uniqKey="Tang J">JW Tang</name>
</author>
<author>
<name sortKey="Noakes, Cj" uniqKey="Noakes C">CJ Noakes</name>
</author>
<author>
<name sortKey="Nielson, Pv" uniqKey="Nielson P">PV Nielson</name>
</author>
<author>
<name sortKey="Eames, I" uniqKey="Eames I">I Eames</name>
</author>
<author>
<name sortKey="Nicolle, A" uniqKey="Nicolle A">A Nicolle</name>
</author>
<author>
<name sortKey="Li, Y" uniqKey="Li Y">Y Li</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Hathway, Ea" uniqKey="Hathway E">EA Hathway</name>
</author>
<author>
<name sortKey="Noakes, Cj" uniqKey="Noakes C">CJ Noakes</name>
</author>
<author>
<name sortKey="Sleigh, Pa" uniqKey="Sleigh P">PA Sleigh</name>
</author>
<author>
<name sortKey="Fletcher, La" uniqKey="Fletcher L">LA Fletcher</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Hung, Hck" uniqKey="Hung H">HCK Hung</name>
</author>
<author>
<name sortKey="Chan, Dwt" uniqKey="Chan D">DWT Chan</name>
</author>
<author>
<name sortKey="Law, Lkc" uniqKey="Law L">LKC Law</name>
</author>
<author>
<name sortKey="Chan, Ehw" uniqKey="Chan E">EHW Chan</name>
</author>
<author>
<name sortKey="Wong, Esw" uniqKey="Wong E">ESW Wong</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Gormley, M" uniqKey="Gormley M">M Gormley</name>
</author>
<author>
<name sortKey="Swaffield, Ja" uniqKey="Swaffield J">JA Swaffield</name>
</author>
<author>
<name sortKey="Sleigh, Pa" uniqKey="Sleigh P">PA Sleigh</name>
</author>
<author>
<name sortKey="Noakes, Cj" uniqKey="Noakes C">CJ Noakes</name>
</author>
</analytic>
</biblStruct>
<biblStruct></biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Swaffield, J" uniqKey="Swaffield J">J. Swaffield</name>
</author>
<author>
<name sortKey="Gormley, M" uniqKey="Gormley M">M Gormley</name>
</author>
<author>
<name sortKey="Wright, G" uniqKey="Wright G">G Wright</name>
</author>
<author>
<name sortKey="Mcdougall, I" uniqKey="Mcdougall I">I McDougall</name>
</author>
</analytic>
</biblStruct>
<biblStruct></biblStruct>
<biblStruct></biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Gormley, M" uniqKey="Gormley M">M Gormley</name>
</author>
<author>
<name sortKey="Templeton, K" uniqKey="Templeton K">K Templeton</name>
</author>
<author>
<name sortKey="Kelly, Da" uniqKey="Kelly D">DA Kelly</name>
</author>
<author>
<name sortKey="Hardie, A" uniqKey="Hardie A">A Hardie</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Aspray, Tj" uniqKey="Aspray T">TJ Aspray</name>
</author>
<author>
<name sortKey="Hansen, Sk" uniqKey="Hansen S">SK Hansen</name>
</author>
<author>
<name sortKey="Burns, Rg" uniqKey="Burns R">RG Burns</name>
</author>
</analytic>
</biblStruct>
<biblStruct></biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Stewart, Sl" uniqKey="Stewart S">SL Stewart</name>
</author>
<author>
<name sortKey="Grinshpun, Sa" uniqKey="Grinshpun S">SA Grinshpun</name>
</author>
<author>
<name sortKey="Willeke, K" uniqKey="Willeke K">K Willeke</name>
</author>
<author>
<name sortKey="Terzieva, S" uniqKey="Terzieva S">S Terzieva</name>
</author>
<author>
<name sortKey="Ulevicius, V" uniqKey="Ulevicius V">V Ulevicius</name>
</author>
<author>
<name sortKey="Donnelly, J" uniqKey="Donnelly J">J Donnelly</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Chang, Cw" uniqKey="Chang C">CW Chang</name>
</author>
<author>
<name sortKey="Hwang, Yh" uniqKey="Hwang Y">YH Hwang</name>
</author>
<author>
<name sortKey="Grinshpun, Sa" uniqKey="Grinshpun S">SA Grinshpun</name>
</author>
<author>
<name sortKey="Macher, Ja" uniqKey="Macher J">JA Macher</name>
</author>
<author>
<name sortKey="Willeke, K" uniqKey="Willeke K">K Willeke</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Wise, Afe" uniqKey="Wise A">AFE Wise</name>
</author>
<author>
<name sortKey="Swaffield, Ja" uniqKey="Swaffield J">JA Swaffield</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Swaffield, Ja" uniqKey="Swaffield J">JA Swaffield</name>
</author>
<author>
<name sortKey="Campbell, Dp" uniqKey="Campbell D">DP Campbell</name>
</author>
<author>
<name sortKey="Gormley, M" uniqKey="Gormley M">M Gormley</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Swaffield, Ja" uniqKey="Swaffield J">JA Swaffield</name>
</author>
<author>
<name sortKey="Campbell, Dp" uniqKey="Campbell D">DP Campbell</name>
</author>
<author>
<name sortKey="Gormley, M" uniqKey="Gormley M">M Gormley</name>
</author>
</analytic>
</biblStruct>
<biblStruct>
<analytic>
<author>
<name sortKey="Gormley, M" uniqKey="Gormley M">M. Gormley</name>
</author>
</analytic>
</biblStruct>
<biblStruct></biblStruct>
</listBibl>
</div1>
</back>
</TEI>
<pmc article-type="research-article">
<pmc-dir>properties open_access</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">PLoS One</journal-id>
<journal-id journal-id-type="iso-abbrev">PLoS ONE</journal-id>
<journal-id journal-id-type="publisher-id">plos</journal-id>
<journal-id journal-id-type="pmc">plosone</journal-id>
<journal-title-group>
<journal-title>PLoS ONE</journal-title>
</journal-title-group>
<issn pub-type="epub">1932-6203</issn>
<publisher>
<publisher-name>Public Library of Science</publisher-name>
<publisher-loc>San Francisco, CA USA</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">28187135</article-id>
<article-id pub-id-type="pmc">5302810</article-id>
<article-id pub-id-type="doi">10.1371/journal.pone.0171556</article-id>
<article-id pub-id-type="publisher-id">PONE-D-16-21118</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Research Article</subject>
</subj-group>
<subj-group subj-group-type="Discipline-v3">
<subject>Physical Sciences</subject>
<subj-group>
<subject>Physics</subject>
<subj-group>
<subject>Classical Mechanics</subject>
<subj-group>
<subject>Continuum Mechanics</subject>
<subj-group>
<subject>Fluid Mechanics</subject>
<subj-group>
<subject>Fluid Dynamics</subject>
<subj-group>
<subject>Flow Rate</subject>
</subj-group>
</subj-group>
</subj-group>
</subj-group>
</subj-group>
</subj-group>
</subj-group>
<subj-group subj-group-type="Discipline-v3">
<subject>Medicine and Health Sciences</subject>
<subj-group>
<subject>Infectious Diseases</subject>
<subj-group>
<subject>Viral Diseases</subject>
<subj-group>
<subject>SARS</subject>
</subj-group>
</subj-group>
</subj-group>
</subj-group>
<subj-group subj-group-type="Discipline-v3">
<subject>Biology and Life Sciences</subject>
<subj-group>
<subject>Organisms</subject>
<subj-group>
<subject>Bacteria</subject>
<subj-group>
<subject>Pseudomonas</subject>
<subj-group>
<subject>Pseudomonas Putida</subject>
</subj-group>
</subj-group>
</subj-group>
</subj-group>
</subj-group>
<subj-group subj-group-type="Discipline-v3">
<subject>Medicine and Health Sciences</subject>
<subj-group>
<subject>Pathology and Laboratory Medicine</subject>
<subj-group>
<subject>Pathogens</subject>
</subj-group>
</subj-group>
</subj-group>
<subj-group subj-group-type="Discipline-v3">
<subject>Research and Analysis Methods</subject>
<subj-group>
<subject>Experimental Organism Systems</subject>
<subj-group>
<subject>Model Organisms</subject>
</subj-group>
</subj-group>
</subj-group>
<subj-group subj-group-type="Discipline-v3">
<subject>Research and Analysis Methods</subject>
<subj-group>
<subject>Model Organisms</subject>
</subj-group>
</subj-group>
<subj-group subj-group-type="Discipline-v3">
<subject>Biology and Life Sciences</subject>
<subj-group>
<subject>Microbiology</subject>
<subj-group>
<subject>Medical Microbiology</subject>
<subj-group>
<subject>Microbial Pathogens</subject>
<subj-group>
<subject>Bacterial Pathogens</subject>
</subj-group>
</subj-group>
</subj-group>
</subj-group>
</subj-group>
<subj-group subj-group-type="Discipline-v3">
<subject>Medicine and Health Sciences</subject>
<subj-group>
<subject>Pathology and Laboratory Medicine</subject>
<subj-group>
<subject>Pathogens</subject>
<subj-group>
<subject>Microbial Pathogens</subject>
<subj-group>
<subject>Bacterial Pathogens</subject>
</subj-group>
</subj-group>
</subj-group>
</subj-group>
</subj-group>
<subj-group subj-group-type="Discipline-v3">
<subject>Physical Sciences</subject>
<subj-group>
<subject>Physics</subject>
<subj-group>
<subject>Classical Mechanics</subject>
<subj-group>
<subject>Dynamics</subject>
<subj-group>
<subject>Aerodynamics</subject>
<subj-group>
<subject>Air Flow</subject>
</subj-group>
</subj-group>
</subj-group>
</subj-group>
</subj-group>
</subj-group>
<subj-group subj-group-type="Discipline-v3">
<subject>Physical Sciences</subject>
<subj-group>
<subject>Physics</subject>
<subj-group>
<subject>Condensed Matter Physics</subject>
<subj-group>
<subject>Phase Transitions</subject>
<subj-group>
<subject>Vaporization</subject>
<subj-group>
<subject>Evaporation</subject>
</subj-group>
</subj-group>
</subj-group>
</subj-group>
</subj-group>
</subj-group>
</article-categories>
<title-group>
<article-title>Pathogen cross-transmission via building sanitary plumbing systems in a full scale pilot test-rig</article-title>
<alt-title alt-title-type="running-head">Pathogen cross-transmission via plumbing systems</alt-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<contrib-id authenticated="true" contrib-id-type="orcid">http://orcid.org/0000-0003-3418-4621</contrib-id>
<name>
<surname>Gormley</surname>
<given-names>Michael</given-names>
</name>
<xref ref-type="corresp" rid="cor001">*</xref>
<xref ref-type="aff" rid="aff001"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Aspray</surname>
<given-names>Thomas J.</given-names>
</name>
<xref ref-type="aff" rid="aff001"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Kelly</surname>
<given-names>David A.</given-names>
</name>
<xref ref-type="aff" rid="aff001"></xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Rodriguez-Gil</surname>
<given-names>Cristina</given-names>
</name>
<xref ref-type="aff" rid="aff001"></xref>
</contrib>
</contrib-group>
<aff id="aff001">
<addr-line>School of Energy, Geoscience, Infrastructure and Society, Heriot-Watt University, Riccarton Campus, Edinburgh, United Kingdom</addr-line>
</aff>
<contrib-group>
<contrib contrib-type="editor">
<name>
<surname>Bach</surname>
<given-names>Horacio</given-names>
</name>
<role>Editor</role>
<xref ref-type="aff" rid="edit1"></xref>
</contrib>
</contrib-group>
<aff id="edit1">
<addr-line>University of British Columbia, CANADA</addr-line>
</aff>
<author-notes>
<fn fn-type="COI-statement" id="coi001">
<p>
<bold>Competing Interests: </bold>
MG is a named inventor on a Patent for a defective trap identification system. MG received funding to do the research from Dyteqta Ltd. who played no role in study design, data collection, data analysis, data interpretation, or writing of the report. The corresponding author had final responsibility for the decision to submit for publication. TJA DAK and CR have declared that no competing interests exist. Patent details (Michael Gormley named inventor): Faulty Trap Identification system - Patent no. GB2441788 publication date 9th November 2011 and US 2010/0000298A1 - publication date Jan 7 2010. Patent owned by Heriot-Watt University and licensed to Dyteqta Ltd. This does not alter our adherence to PLOS ONE policies on sharing data and materials.</p>
</fn>
<fn fn-type="con">
<p>
<list list-type="simple">
<list-item>
<p>
<bold>Conceptualization:</bold>
MG TJA DAK.</p>
</list-item>
<list-item>
<p>
<bold>Data curation:</bold>
MG TJA DAK CRG.</p>
</list-item>
<list-item>
<p>
<bold>Formal analysis:</bold>
MG TJA DAK.</p>
</list-item>
<list-item>
<p>
<bold>Funding acquisition:</bold>
MG.</p>
</list-item>
<list-item>
<p>
<bold>Investigation:</bold>
MG TJA DAK CRG.</p>
</list-item>
<list-item>
<p>
<bold>Methodology:</bold>
MG TJA DAK CRG.</p>
</list-item>
<list-item>
<p>
<bold>Project administration:</bold>
MG.</p>
</list-item>
<list-item>
<p>
<bold>Resources:</bold>
MG TJA DAK.</p>
</list-item>
<list-item>
<p>
<bold>Supervision:</bold>
MG TJA.</p>
</list-item>
<list-item>
<p>
<bold>Validation:</bold>
MG TJA DAK CRG.</p>
</list-item>
<list-item>
<p>
<bold>Writing – original draft:</bold>
MG TJA DAK.</p>
</list-item>
<list-item>
<p>
<bold>Writing – review & editing:</bold>
MG TJA DAK CRG.</p>
</list-item>
</list>
</p>
</fn>
<corresp id="cor001">* E-mail:
<email>m.gormley@hw.ac.uk</email>
</corresp>
</author-notes>
<pub-date pub-type="epub">
<day>10</day>
<month>2</month>
<year>2017</year>
</pub-date>
<pub-date pub-type="collection">
<year>2017</year>
</pub-date>
<volume>12</volume>
<issue>2</issue>
<elocation-id>e0171556</elocation-id>
<history>
<date date-type="received">
<day>25</day>
<month>5</month>
<year>2016</year>
</date>
<date date-type="accepted">
<day>23</day>
<month>1</month>
<year>2017</year>
</date>
</history>
<permissions>
<copyright-statement>© 2017 Gormley et al</copyright-statement>
<copyright-year>2017</copyright-year>
<copyright-holder>Gormley et al</copyright-holder>
<license xlink:href="http://creativecommons.org/licenses/by/4.0/">
<license-p>This is an open access article distributed under the terms of the
<ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by/4.0/">Creative Commons Attribution License</ext-link>
, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.</license-p>
</license>
</permissions>
<self-uri content-type="pdf" xlink:href="pone.0171556.pdf"></self-uri>
<abstract>
<p>The WHO Consensus Document on the epidemiology of the SARS epidemic in 2003, included a report on a concentrated outbreak in one Hong Kong housing block which was considered a ‘super-spreading event’. The WHO report conjectured that the sanitary plumbing system was one transmission route for the virus. Empty U-traps allowed the aerosolised virus to enter households from the sewerage system. No biological evidence was presented. This research reports evidence that pathogens can be aerosolised and transported on airstreams within sanitary plumbing systems and enter buildings via empty U-traps. A sanitary plumbing system was built, representing two floors of a building, with simulated toilet flushes on the lower floor and a sterile chamber with extractor fan on the floor above. Cultures of a model organism,
<italic>Pseudomonas putida</italic>
at 10
<sup>6</sup>
–10
<sup>9</sup>
cfu ml
<sup>-1</sup>
in 0·85% NaCl were flushed into the system in volumes of 6 to 20 litres to represent single or multiple toilet flushes. Air and surface samples were cultured on agar plates and assessed qualitatively and semi-quantitatively. Flushing from a toilet into a sanitary plumbing system generated enough turbulence to aerosolise pathogens. Typical sanitary plumbing system airflows (between 20–30 ls
<sup>-1</sup>
) were sufficient to carry aerosolised pathogens between different floors of a building. Empty U-traps allowed aerosolised pathogens to enter the chamber, encouraging cross-transmission. All parts of the system were found to be contaminated post-flush. Empty U-traps have been observed in many buildings and a risk assessment indicates the potential for high risk cross-transmission under defect conditions in buildings with high pathogen loading such as hospitals. Under defective conditions (which are not uncommon) aerosolised pathogens can be carried on the airflows within sanitary plumbing systems. Our findings show that greater consideration should be given to this mode of pathogen transmission.</p>
</abstract>
<funding-group>
<award-group id="award001">
<funding-source>
<institution>Dyteqta Ltd.</institution>
</funding-source>
<award-id>D13R10169</award-id>
<principal-award-recipient>
<contrib-id authenticated="true" contrib-id-type="orcid">http://orcid.org/0000-0003-3418-4621</contrib-id>
<name>
<surname>Gormley</surname>
<given-names>Michael</given-names>
</name>
</principal-award-recipient>
</award-group>
<funding-statement>A small Funding grant (£15k) was obtained from Dyteqta Ltd., Funding No.D13R10169. The funder of the study had no role in study design, data collection, data analysis, data interpretation, or writing of the report. The corresponding author had final responsibility for the decision to submit for publication.</funding-statement>
</funding-group>
<counts>
<fig-count count="6"></fig-count>
<table-count count="4"></table-count>
<page-count count="13"></page-count>
</counts>
<custom-meta-group>
<custom-meta id="data-availability">
<meta-name>Data Availability</meta-name>
<meta-value>All relevant data are within the paper and its Supporting Information files.</meta-value>
</custom-meta>
</custom-meta-group>
</article-meta>
<notes>
<title>Data Availability</title>
<p>All relevant data are within the paper and its Supporting Information files.</p>
</notes>
</front>
<body>
<sec sec-type="intro" id="sec001">
<title>Introduction</title>
<p>The spread of disease via building environmental systems is, on the whole, little understood. Sporadic investigations on pathogen transmission have mostly focussed on
<italic>Legionella pneumophila</italic>
in air conditioning and water supply systems [
<xref rid="pone.0171556.ref001" ref-type="bibr">1</xref>
<xref rid="pone.0171556.ref005" ref-type="bibr">5</xref>
] with some additional work being carried out on biofilm formation in sinks and pathogen fallout from flushing toilets [
<xref rid="pone.0171556.ref006" ref-type="bibr">6</xref>
<xref rid="pone.0171556.ref009" ref-type="bibr">9</xref>
]. While the study of
<italic>L</italic>
.
<italic>pneumophila</italic>
transmission from water supply systems is now well understood, principally due to the steady, predictable nature of the water flows involved, this is not the case for the transmission of pathogens from the sanitary plumbing system. These systems are characterised by unsteady and turbulent wastewater flows due to random discharges from sanitary fittings such as sinks, baths, showers and toilets. These flows, in turn, induce unsteady transient airflows inside the plumbing pipe network. Wastewater flows inside the sanitary plumbing system lead to pressure fluctuations which can compromise the fragile water trap seals (U-traps) which form the only protection between the sanitary plumbing system and the people within buildings.</p>
<p>Since the SARS outbreak in 2002/2003 [
<xref rid="pone.0171556.ref010" ref-type="bibr">10</xref>
], there has been growing concern regarding the role that the sanitary plumbing system played in the transmission of the virus. The World Health Organisation (WHO) Consensus Document [
<xref rid="pone.0171556.ref011" ref-type="bibr">11</xref>
] on the epidemiology of the outbreak included a report on the transmission of SARS in one particular housing block in Hong Kong (Amoy Gardens) which was considered as a ‘super-spreading event’. A total of 341 cases of SARS were reported at Amoy Gardens, resulting in 42 deaths. One of the reasons cited for this high infection rate was the spread of the virus via the building’s sanitary plumbing system. The WHO conjecture stated that
<italic>“dry U-traps in bathroom floor drains provided a conduit for contaminated sewage droplets to enter households</italic>
.
<italic>A significant virus load had built up in the sewer system as an increasing number of SARS cases with diarrhoea excreted virus</italic>
.
<italic>Virus was aerosolized within the confines of very small bathrooms and may have been inhaled</italic>
,
<italic>ingested or transmitted indirectly by contact with fomites as the aerosol settled”</italic>
[
<xref rid="pone.0171556.ref011" ref-type="bibr">11</xref>
]. The U-traps (particularly in floor gullies) were found to be depleted of water, thus having lost their sealing function and providing an open connection between the sanitary plumbing system and different apartments within the building. As the number of SARS cases increased, the sanitary plumbing system became a reservoir for the virus due to diarrhoeal excretion. The WHO hypothesis followed that the virus became aerosolised when discharged into the sanitary plumbing system which provided a conduit for virus-laden aerosols to enter apartments via depleted U-traps. This process was exacerbated by the naturally occurring airflows within the sanitary plumbing system and the negative pressures within bathrooms as a result of extract fans. The combination of these factors presented a pathway for pathogen transmission heretofore unexplored. The process is illustrated in
<xref ref-type="fig" rid="pone.0171556.g001">Fig 1</xref>
.</p>
<fig id="pone.0171556.g001" orientation="portrait" position="float">
<object-id pub-id-type="doi">10.1371/journal.pone.0171556.g001</object-id>
<label>Fig 1</label>
<caption>
<title>SARS transmission route at Amoy Gardens via the sanitary plumbing system.</title>
</caption>
<graphic xlink:href="pone.0171556.g001"></graphic>
</fig>
<p>The interconnectedness of the sanitary plumbing system, and the airflow communication pathways that exist between all system points are rarely understood and almost never considered within the context of pathogen transmission.
<xref ref-type="fig" rid="pone.0171556.g002">Fig 2</xref>
illustrates the interconnected nature of the sanitary plumbing system for a building similar to Amoy Gardens. Aerosols and droplets carrying infectious agents can be carried in airflows [
<xref rid="pone.0171556.ref012" ref-type="bibr">12</xref>
,
<xref rid="pone.0171556.ref013" ref-type="bibr">13</xref>
] and so an understanding of the airflows within both the sanitary plumbing system and within the building itself is imperative in order to track transmission routes.</p>
<fig id="pone.0171556.g002" orientation="portrait" position="float">
<object-id pub-id-type="doi">10.1371/journal.pone.0171556.g002</object-id>
<label>Fig 2</label>
<caption>
<title>Interconnectedness of whole building.</title>
</caption>
<graphic xlink:href="pone.0171556.g002"></graphic>
</fig>
<p>While research into the potential mechanisms of the SARS transmission at Amoy Gardens proved that there was an airflow path between the sanitary plumbing system and different parts of the building when the U-trap had no water seal [
<xref rid="pone.0171556.ref014" ref-type="bibr">14</xref>
,
<xref rid="pone.0171556.ref015" ref-type="bibr">15</xref>
], it was only hypothesised that pathogens could be transmitted within these airflows and could deliver an infective exposure dose. This paper sets out to test the WHO hypothesis by qualitatively and quantitatively tracking the transmission of a model organism chosen to represent pathogens generally within the airflows of a full scale pilot test-rig representing a two storey sanitary plumbing system designed to current European standards [
<xref rid="pone.0171556.ref016" ref-type="bibr">16</xref>
]. The data gained from the pilot test-rig is supplemented with on-site observational data of sanitary plumbing defects collected over many years by the Authors to identify the risk factors of transmission.</p>
</sec>
<sec sec-type="materials|methods" id="sec002">
<title>Methods</title>
<sec id="sec003">
<title>Full scale pilot test-rig setup</title>
<p>A full scale pilot test-rig was constructed to conform with BS EN 12056 [
<xref rid="pone.0171556.ref016" ref-type="bibr">16</xref>
]; the British and European Standard for the design and construction of sanitary plumbing systems. The two floor test rig is shown in
<xref ref-type="fig" rid="pone.0171556.g003">Fig 3</xref>
and was constructed with standard 100 mm diameter PVC-u rigid pipe and consisted of a main vertical pipe (stack) connected to a horizontal drain. The system included a receptacle pipe to hold an inoculum which was discharged into the main vertical stack at the lower floor via a toilet flush simulator valve. The valve was operated to simulate a flush similar in characteristics to a standard drop valve toilet (a typical toilet flush volume in the U.K. is 6 litres, however other legacy toilets have flush volumes of 7.5, 9 and 13 litres, these are also typical volumes for toilets globally). The simulator had the capacity for either a single standard 6 litre flush or multiple flushes [
<xref rid="pone.0171556.ref017" ref-type="bibr">17</xref>
]. The flushed inoculum was then directed to a collection tank. At the upper floor, a test chamber was constructed to represent a bathroom containing a toilet, of which the U-trap could be emptied of water, and an extract fan connected to a flexible duct at the end of which air samples could be taken. A typical U-trap for a toilet will contain 1–1.5 litres of water and for sinks, baths, showers and other fixtures the volume of water will be up to 400ml depending on the type and model. Two further test points (Test Point 1 and Test Point 2) were located between the lower and upper floors, and a further test point (Test Point 3) was located within the horizontal pipe within the test chamber to allow air samples to be taken from within the system.</p>
<fig id="pone.0171556.g003" orientation="portrait" position="float">
<object-id pub-id-type="doi">10.1371/journal.pone.0171556.g003</object-id>
<label>Fig 3</label>
<caption>
<title>Full scale 2-storey pilot test-rig.</title>
</caption>
<graphic xlink:href="pone.0171556.g003"></graphic>
</fig>
<p>Airflow rates within the test-rig were adjusted using the extract fan to correspond to those found in real systems.</p>
<p>While there is currently very little literature on the airflows found within sanitary plumbing systems [
<xref rid="pone.0171556.ref018" ref-type="bibr">18</xref>
], one key piece of literature investigated the airflow within the sanitary plumbing system at Amoy Gardens [
<xref rid="pone.0171556.ref011" ref-type="bibr">11</xref>
] and found the airflow rate at a bathroom floor drain to be 28 ls
<sup>-1</sup>
with a direction of flow from the sanitary plumbing system into the bathroom. Investigations by the Authors [
<xref rid="pone.0171556.ref019" ref-type="bibr">19</xref>
,
<xref rid="pone.0171556.ref020" ref-type="bibr">20</xref>
] into the airflow characteristics within sanitary plumbing systems of a three-storey house found similar results with peak airflow rates ranging from 18·6 ls
<sup>-1</sup>
to 26·7 ls
<sup>-1</sup>
. Smoke tests of this three-storey system showed that plumes of air would enter the bathroom when the U-trap was missing. Airflow rates within the test-rig were varied up to a maximum of 29.8 ls
<sup>-1</sup>
or operated without airflow.</p>
<p>There are two main ways in which airflow can occur within a sanitary plumbing system:</p>
<list list-type="order">
<list-item>
<p>As a result of wastewater flowing down the vertical stack. This has the effect of entraining an airflow into the system from the top. The direction of this airflow is from top to bottom.</p>
</list-item>
<list-item>
<p>Air flowing out of the main sewer and through the vertical stack to the exit at the top of the building. This airflow depends on many factors including; sewer activity levels, temperature differentials between top and bottom of the vertical stack, chimney effects and wind shear across the top to the vertical stack. The direction of this airflow is from bottom to top.</p>
</list-item>
</list>
<p>The airflow of most interest in this study is defined in ii) above. This is because the airflows from i) will flow from the building into the sewer. The flows described in ii) can travel from the sewer and into the building, and so have potential to carry aerosolised pathogens with it. The upward flow of air will travel the shortest route towards atmospheric pressure and an empty U-trap provides such a route.</p>
<p>Only two studies have published relevant data on airflows from sanitary plumbing systems:</p>
<list list-type="order">
<list-item>
<p>Amoy Gardens (a50 storey building) was found to be 28 ls
<sup>-1</sup>
</p>
</list-item>
<list-item>
<p>The 3storey house was recorded 18.6 and 26.7 ls
<sup>-1</sup>
</p>
</list-item>
</list>
<p>The task of inducing a flowrate in the pilot test-rig was difficult to do precisely (small variations in system operation and the random nature of some of the variables meant that exact flow rates could not be repeated. It was decided to set 3 ranges of airflow rate in order to carry out test repeats. The airflow rates were classified as either low (< 20 ls
<sup>-1</sup>
), medium (20 ls
<sup>-1</sup>
–27 ls
<sup>-1</sup>
) or high (>27ls
<sup>-1</sup>
).</p>
<sec id="sec004">
<title>
<italic>Pseudomonas putida</italic>
culture preparation</title>
<p>Due to the preliminary nature of this work, a class 1 non-genetically modified bacterium,
<italic>Pseudomonas putida</italic>
KT2440 [
<xref rid="pone.0171556.ref021" ref-type="bibr">21</xref>
], was used as a reliable model organism in 10 experiments to assess pathogen cross contamination. Pure colonies were picked from agar plates, inoculated into Erlenmeyer flasks containing tryptone soya broth and incubated overnight at 30°C with orbital shaking. The resulting stock culture was diluted in 0·85% (w/v) NaCl to provide the inoculum. An aliquot of this culture was used to determine cell concentration. For experiments 1–5, an inoculum of 10
<sup>7</sup>
−10
<sup>9</sup>
cfu ml
<sup>-1</sup>
was used. For experiments 6–10, a lower inoculum concentration (10
<sup>6</sup>
cfu ml
<sup>-1</sup>
) was used to reduce number of cells reaching the active air sampler and oversaturating.</p>
</sec>
<sec id="sec005">
<title>Monitoring approaches</title>
<p>A) Passive sampler (Experiments 1, 2, 4–7)</p>
<p>Stainless steel ‘upper discs’ from domestic cafetieres (or coffee presses) were adapted as novel passive air samplers (i.e. not described in BS EN ISO 14698–1:2003) [
<xref rid="pone.0171556.ref022" ref-type="bibr">22</xref>
] and inserted into test points indicated in
<xref ref-type="fig" rid="pone.0171556.g003">Fig 3</xref>
. Each test point was carefully sealed whether in use or not. Each sampler was sterilised in sealed bags by autoclaving prior to use. After use, each sampler was carefully removed from its test point and pressed onto a standard 90 mm diameter Pseudomonas Isolation Agar (PIA; Sigma Aldrich) plate (resulting growth pattern as illustrated in
<xref ref-type="fig" rid="pone.0171556.g004">Fig 4</xref>
). The plates were incubated overnight at 30°C.</p>
<fig id="pone.0171556.g004" orientation="portrait" position="float">
<object-id pub-id-type="doi">10.1371/journal.pone.0171556.g004</object-id>
<label>Fig 4</label>
<caption>
<title>Pattern and number of viable
<italic>Pseudomonas putida</italic>
KT2440 at the end of the horizontal pipe (experiment 9).</title>
</caption>
<graphic xlink:href="pone.0171556.g004"></graphic>
</fig>
<p>B) Swabs and contact plates (Experiments 1–2, 6- and 7)</p>
<p>Swabs were used to take surface samples during Experiment 1, after which, 55 mm diameter (23·8 cm
<sup>2</sup>
area) contact plates were used. For Experiment 2, non-selective nutrient plates were used, after which, PIA plates were used for subsequent Experiments (as required). Contact plates were touched once onto test chamber surfaces and incubated for 24 h at 30°C.</p>
<p>C) Active air sampler (Experiments 2–5, 8–10)</p>
<p>A Surface Air System (SAS Super IAQ; International PBI S.p.A) indoor air quality monitor, containing a single 90 mm diameter PIA plate, was setup at the end of the flexible duct connected to the extract fan. The monitor was set to sample 250 litres of air at a rate of 100 litres per min prior to each experiment. The PIA plate was replaced and air sampling repeated at the same time as the test inoculum (containing
<italic>P</italic>
.
<italic>putida</italic>
KT2440) was flushed into the system. PIA plates were incubated for 24 h at 30°C before colony counting.</p>
</sec>
<sec id="sec006">
<title>Toilet U-trap tests (Experiments 8, 9 and 10)</title>
<p>A standard domestic toilet was sterilised by autoclaving and fitted into the test chamber (see
<xref ref-type="fig" rid="pone.0171556.g003">Fig 3</xref>
). A partial water trap was prepared using 180 ml (Experiment 8) and 350 ml (Experiment 10) sterile 0·85% (w/v) NaCl, respectively. An empty U-trap was used for Experiment 9. After Experiments 8 and 10, the partial water trap solution was collected and vacuum filtered through a sterile 0·45 μm filter. The filter was incubated on a PIA standard (90 mm diameter) plate. Colonies were counted after 24–72 h.</p>
<p>For experiments 9 and 10, a perforated steel plate was sterilised in sealed bags by autoclaving prior to use and positioned flat on the toilet bowl (
<xref ref-type="fig" rid="pone.0171556.g005">Fig 5B</xref>
). After each experiment, the plate was reversed and sampled in a grid like fashion using PIA contact plates (
<xref ref-type="fig" rid="pone.0171556.g005">Fig 5B</xref>
).</p>
<fig id="pone.0171556.g005" orientation="portrait" position="float">
<object-id pub-id-type="doi">10.1371/journal.pone.0171556.g005</object-id>
<label>Fig 5</label>
<caption>
<p>
<bold>Toilet bowl (A) and toilet seat (B) surface sampling locations.</bold>
Front of toilet to right of both images.</p>
</caption>
<graphic xlink:href="pone.0171556.g005"></graphic>
</fig>
</sec>
<sec id="sec007">
<title>Test- rig decontamination</title>
<p>The test-rig was fully decontaminated between each experiment using a biochlor® solution flush followed by rinsing with mains tap water. The rig sterility was checked using the active air sampler and PIA plates and found to be effective. The chamber was decontaminated by surface sterilisation and confirmed clean with the use of PIA contact plates.</p>
</sec>
<sec id="sec008">
<title>On-site observations of defective U-traps</title>
<p>In conjunction with the full scale 2-storey pilot test-rig experiments, observation data from previously completed on-site research were collated in terms of observed depleted U-trap occurrence. The data was collated by building type and location, size of building and location of depleted U-trap within the building. The extent of the depletion and a likely cause was also assessed.</p>
</sec>
</sec>
</sec>
<sec id="sec009">
<title>Results and discussion</title>
<sec id="sec010">
<title>Microbiological results</title>
<p>The microbiological results from the experiments using the full scale pilot test-rig are shown in Tables
<xref rid="pone.0171556.t001" ref-type="table">1</xref>
and
<xref rid="pone.0171556.t002" ref-type="table">2</xref>
. Experiments 1 to 7 are those with no U-trap connected at the upper floor and an empty test chamber, whereas, Experiments 8–10 include a toilet connected at the upper floor in the chamber as illustrated in
<xref ref-type="fig" rid="pone.0171556.g003">Fig 3</xref>
.</p>
<table-wrap id="pone.0171556.t001" orientation="portrait" position="float">
<object-id pub-id-type="doi">10.1371/journal.pone.0171556.t001</object-id>
<label>Table 1</label>
<caption>
<title>Empty chamber experiments.</title>
<p>Reported values are colony forming units (CFU) with CFU/cm
<sup>2</sup>
in parenthesis.</p>
</caption>
<alternatives>
<graphic id="pone.0171556.t001g" xlink:href="pone.0171556.t001"></graphic>
<table frame="hsides" rules="groups">
<colgroup span="1">
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
</colgroup>
<thead>
<tr>
<th align="center" rowspan="1" colspan="1">Expt.</th>
<th align="center" rowspan="1" colspan="1">Airflow</th>
<th align="center" rowspan="1" colspan="1">Inoc.</th>
<th align="center" rowspan="1" colspan="1">Inoc.</th>
<th align="center" colspan="3" rowspan="2">Passive sampler CFU</th>
<th align="center" colspan="10" rowspan="1">Chamber surface</th>
<th align="center" rowspan="1" colspan="1">Active air</th>
</tr>
<tr>
<th align="center" rowspan="1" colspan="1">no.</th>
<th align="center" rowspan="1" colspan="1">rate</th>
<th align="center" rowspan="1" colspan="1">vol (l)</th>
<th align="center" rowspan="1" colspan="1">CFU</th>
<th align="center" colspan="10" rowspan="1">CFU (CFU/cm
<sup>2</sup>
)</th>
<th align="center" rowspan="1" colspan="1">sampler</th>
</tr>
<tr>
<th align="center" rowspan="1" colspan="1"></th>
<th align="center" rowspan="1" colspan="1"></th>
<th align="left" rowspan="1" colspan="1"></th>
<th align="center" rowspan="1" colspan="1">(ml
<sup>-1</sup>
)</th>
<th align="center" rowspan="2" colspan="1">TP1</th>
<th align="center" rowspan="2" colspan="1">TP2</th>
<th align="center" rowspan="2" colspan="1">TP3</th>
<th align="center" colspan="5" rowspan="1">Pre-flush</th>
<th align="center" colspan="5" rowspan="1">Post-flush</th>
<th align="center" rowspan="1" colspan="1">CFU</th>
</tr>
<tr>
<th align="center" rowspan="1" colspan="1"> </th>
<th align="center" rowspan="1" colspan="1"> </th>
<th align="center" rowspan="1" colspan="1"> </th>
<th align="left" rowspan="1" colspan="1"> </th>
<th align="left" rowspan="1" colspan="1">B</th>
<th align="left" rowspan="1" colspan="1">L</th>
<th align="left" rowspan="1" colspan="1">T</th>
<th align="left" rowspan="1" colspan="1">R</th>
<th align="center" rowspan="1" colspan="1">F</th>
<th align="center" rowspan="1" colspan="1">B</th>
<th align="center" rowspan="1" colspan="1">L</th>
<th align="center" rowspan="1" colspan="1">T</th>
<th align="center" rowspan="1" colspan="1">R</th>
<th align="center" rowspan="1" colspan="1">F</th>
<th align="center" rowspan="1" colspan="1"> </th>
</tr>
</thead>
<tbody>
<tr>
<td align="center" rowspan="1" colspan="1">1</td>
<td align="center" rowspan="1" colspan="1">HIGH</td>
<td align="center" rowspan="1" colspan="1">6+8+6</td>
<td align="center" rowspan="1" colspan="1">1·93x10
<sup>8</sup>
</td>
<td align="center" rowspan="1" colspan="1">752</td>
<td align="center" rowspan="1" colspan="1">51</td>
<td align="left" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="left" rowspan="1" colspan="1"> </td>
</tr>
<tr>
<td align="center" rowspan="1" colspan="1">2</td>
<td align="center" rowspan="1" colspan="1">HIGH</td>
<td align="center" rowspan="1" colspan="1">8+3</td>
<td align="center" rowspan="1" colspan="1">9·13x10
<sup>9</sup>
</td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1">45</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">2 (0·08)</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">1 (0·04)</td>
<td align="center" rowspan="1" colspan="1">1 (0·04)</td>
<td align="center" rowspan="1" colspan="1">2 (0·08)</td>
<td align="center" rowspan="1" colspan="1">64</td>
</tr>
<tr>
<td align="center" rowspan="1" colspan="1">3</td>
<td align="center" rowspan="1" colspan="1">HIGH</td>
<td align="center" rowspan="1" colspan="1">6</td>
<td align="center" rowspan="1" colspan="1">1·20x10
<sup>7</sup>
</td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1">197</td>
</tr>
<tr>
<td align="center" rowspan="1" colspan="1">4</td>
<td align="center" rowspan="1" colspan="1">HIGH</td>
<td align="center" rowspan="1" colspan="1">6</td>
<td align="center" rowspan="1" colspan="1">3·28x10
<sup>6</sup>
</td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1">736</td>
<td align="center" rowspan="1" colspan="1">476</td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1">248</td>
</tr>
<tr>
<td align="center" rowspan="1" colspan="1">5</td>
<td align="center" rowspan="1" colspan="1">LOW</td>
<td align="center" rowspan="1" colspan="1">6</td>
<td align="center" rowspan="1" colspan="1">9·10x10
<sup>6</sup>
</td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1">748</td>
<td align="center" rowspan="1" colspan="1">484</td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1">282</td>
</tr>
<tr>
<td align="center" rowspan="1" colspan="1">6</td>
<td align="center" rowspan="1" colspan="1">n/a</td>
<td align="center" rowspan="1" colspan="1">6</td>
<td align="center" rowspan="1" colspan="1">7·33x10
<sup>6</sup>
</td>
<td align="center" rowspan="1" colspan="1">Pos
<xref ref-type="table-fn" rid="t001fn004">
<sup>#</sup>
</xref>
</td>
<td align="left" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">2 (0·08)</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1"> </td>
</tr>
<tr>
<td align="center" rowspan="1" colspan="1">7</td>
<td align="center" rowspan="1" colspan="1">n/a</td>
<td align="center" rowspan="1" colspan="1">6</td>
<td align="center" rowspan="1" colspan="1">4·48x10
<sup>6</sup>
</td>
<td align="left" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1">2</td>
<td align="center" rowspan="1" colspan="1">1</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">2 (0·08)</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1"> </td>
</tr>
</tbody>
</table>
</alternatives>
<table-wrap-foot>
<fn id="t001fn001">
<p>*Air flow rates (ls
<sup>-1</sup>
) equate to; low (<20), medium (20–27) and high (>27)</p>
</fn>
<fn id="t001fn002">
<p>B = bottom wall, L = left wall, T = top wall, R = right wall, F = front wall, TP = Test Point</p>
</fn>
<fn id="t001fn003">
<p>Blank cells indicate where testing was not carried out or sample locations were unavailable</p>
</fn>
<fn id="t001fn004">
<p>
<sup>#</sup>
Passive sampler splashed by flush–count not possible.</p>
</fn>
</table-wrap-foot>
</table-wrap>
<table-wrap id="pone.0171556.t002" orientation="portrait" position="float">
<object-id pub-id-type="doi">10.1371/journal.pone.0171556.t002</object-id>
<label>Table 2</label>
<caption>
<title>Chamber with toilet experiments.</title>
<p>Reported values are colony forming units (CFU) with CFU/cm
<sup>2</sup>
in parenthesis.</p>
</caption>
<alternatives>
<graphic id="pone.0171556.t002g" xlink:href="pone.0171556.t002"></graphic>
<table frame="hsides" rules="groups">
<colgroup span="1">
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
</colgroup>
<thead>
<tr>
<th align="center" rowspan="1" colspan="1">Expt.</th>
<th align="center" rowspan="1" colspan="1">Airflow</th>
<th align="center" rowspan="1" colspan="1">Inoc.</th>
<th align="center" rowspan="1" colspan="1">Inoc. CFU</th>
<th align="center" rowspan="1" colspan="1">U-trap</th>
<th align="left" colspan="5" rowspan="1">Chamber Surface CFU (CFU/cm
<sup>2</sup>
)</th>
<th align="left" colspan="4" rowspan="1">Toilet Surface CFU (CFU/cm
<sup>2</sup>
)</th>
<th align="center" colspan="12" rowspan="1">Toilet seat height</th>
<th align="center" rowspan="1" colspan="1">Active air</th>
</tr>
<tr>
<th align="center" rowspan="1" colspan="1">no.</th>
<th align="center" rowspan="1" colspan="1">rate
<xref ref-type="table-fn" rid="t002fn001">*</xref>
</th>
<th align="center" rowspan="1" colspan="1">vol. (l)</th>
<th align="center" rowspan="1" colspan="1">(ml
<sup>-1</sup>
)</th>
<th align="center" rowspan="1" colspan="1">water (ml)</th>
<th align="center" colspan="5" rowspan="1">Post-flush</th>
<th align="center" colspan="4" rowspan="1">Post-flush</th>
<th align="center" colspan="12" rowspan="1">Post-flush</th>
<th align="center" rowspan="1" colspan="1">sampler</th>
</tr>
<tr>
<th align="center" rowspan="1" colspan="1"> </th>
<th align="left" rowspan="1" colspan="1"> </th>
<th align="center" rowspan="1" colspan="1"> </th>
<th align="left" rowspan="1" colspan="1"> </th>
<th align="center" rowspan="1" colspan="1"> </th>
<th align="center" rowspan="1" colspan="1">B</th>
<th align="center" rowspan="1" colspan="1">L</th>
<th align="center" rowspan="1" colspan="1">T</th>
<th align="center" rowspan="1" colspan="1">R</th>
<th align="center" rowspan="1" colspan="1">F</th>
<th align="center" rowspan="1" colspan="1">1</th>
<th align="center" rowspan="1" colspan="1">2</th>
<th align="center" rowspan="1" colspan="1">3</th>
<th align="center" rowspan="1" colspan="1">4</th>
<th align="center" rowspan="1" colspan="1">P1</th>
<th align="center" rowspan="1" colspan="1">P2</th>
<th align="center" rowspan="1" colspan="1">P3</th>
<th align="center" rowspan="1" colspan="1">P4</th>
<th align="center" rowspan="1" colspan="1">P5</th>
<th align="center" rowspan="1" colspan="1">P6</th>
<th align="center" rowspan="1" colspan="1">P7</th>
<th align="center" rowspan="1" colspan="1">P8</th>
<th align="center" rowspan="1" colspan="1">P9</th>
<th align="center" rowspan="1" colspan="1">P10</th>
<th align="center" rowspan="1" colspan="1">P11</th>
<th align="center" rowspan="1" colspan="1">P12</th>
<th align="center" rowspan="1" colspan="1">CFU</th>
</tr>
</thead>
<tbody>
<tr>
<td align="center" rowspan="1" colspan="1">
<bold>8</bold>
</td>
<td align="center" rowspan="1" colspan="1">Medium</td>
<td align="center" rowspan="1" colspan="1">6</td>
<td align="center" rowspan="1" colspan="1">3·57x10
<sup>8</sup>
</td>
<td align="center" rowspan="1" colspan="1">180</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1">2 (0·08)</td>
<td align="center" rowspan="1" colspan="1">1 (0·04)</td>
<td align="center" rowspan="1" colspan="1">2 (0·08)</td>
<td align="center" rowspan="1" colspan="1">6 (0·25)</td>
<td align="center" rowspan="1" colspan="1">6 (0·25)</td>
<td align="center" rowspan="1" colspan="1">18 (0·76)</td>
<td align="center" rowspan="1" colspan="1">4 (0·17)</td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1">510</td>
</tr>
<tr>
<td align="center" rowspan="1" colspan="1">
<bold>9</bold>
</td>
<td align="center" rowspan="1" colspan="1">Medium</td>
<td align="center" rowspan="1" colspan="1">6</td>
<td align="center" rowspan="1" colspan="1">8·39x10
<sup>8</sup>
</td>
<td align="center" rowspan="1" colspan="1">0</td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1">-</td>
<td align="center" rowspan="1" colspan="1">-</td>
<td align="center" rowspan="1" colspan="1">-</td>
<td align="center" rowspan="1" colspan="1">-</td>
<td align="center" rowspan="1" colspan="1">-</td>
<td align="center" rowspan="1" colspan="1">-</td>
<td align="center" rowspan="1" colspan="1">-</td>
<td align="center" rowspan="1" colspan="1">-</td>
<td align="center" rowspan="1" colspan="1">-</td>
<td align="center" rowspan="1" colspan="1">+</td>
<td align="center" rowspan="1" colspan="1">+</td>
<td align="center" rowspan="1" colspan="1">-</td>
<td align="center" rowspan="1" colspan="1">457</td>
</tr>
<tr>
<td align="center" rowspan="1" colspan="1">
<bold>10</bold>
</td>
<td align="center" rowspan="1" colspan="1">Low</td>
<td align="center" rowspan="1" colspan="1">6</td>
<td align="center" rowspan="1" colspan="1">7·90x10
<sup>6</sup>
</td>
<td align="center" rowspan="1" colspan="1">350</td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1"> </td>
<td align="center" rowspan="1" colspan="1">+</td>
<td align="center" rowspan="1" colspan="1">-</td>
<td align="center" rowspan="1" colspan="1">-</td>
<td align="center" rowspan="1" colspan="1">+</td>
<td align="center" rowspan="1" colspan="1">+</td>
<td align="center" rowspan="1" colspan="1">+</td>
<td align="center" rowspan="1" colspan="1">+</td>
<td align="center" rowspan="1" colspan="1">+</td>
<td align="center" rowspan="1" colspan="1">+</td>
<td align="center" rowspan="1" colspan="1">+</td>
<td align="center" rowspan="1" colspan="1">+</td>
<td align="center" rowspan="1" colspan="1">+</td>
<td align="center" rowspan="1" colspan="1">318</td>
</tr>
</tbody>
</table>
</alternatives>
<table-wrap-foot>
<fn id="t002fn001">
<p>*Air flow rates (ls
<sup>-1</sup>
) equate to; low (<20, medium (20–27) and high (>27)</p>
</fn>
<fn id="t002fn002">
<p>B = bottom wall, L = left wall, T = top wall, R = right wall, F = front wall</p>
</fn>
<fn id="t002fn003">
<p>Blank cells indicate where testing was not carried out or sample locations were unavailable.</p>
</fn>
</table-wrap-foot>
</table-wrap>
<p>Collectively, the 10 experiments confirm that cross-transmission of viable bacteria can occur between adjacent floors of a sanitary plumbing system. The flushing of a toilet containing wastewater on a lower floor contaminated the room (test chamber) on the upper floor. This occurred both with an induced upward airflow (Experiments 1 to 5, and 8–10) and without (Experiments 6 and 7), however, the cross-contamination was less severe in the absence of an airflow based on passive air sampler data. Finally, based on passive air sampler data, Experiments 4 and 5 which had comparable inoculum concentrations show similar numbers of bacteria at test points 2 and 3. This result is supported by active air sampler data at the extractor ducting exit.</p>
<p>Two different approaches were assessed for detecting and quantifying the model bacterium,
<italic>P</italic>
.
<italic>putida</italic>
KT2440, in the test chamber (Tables
<xref rid="pone.0171556.t001" ref-type="table">1</xref>
and
<xref rid="pone.0171556.t002" ref-type="table">2</xref>
). In Experiment 1, swabs were used to assay the test chamber surfaces, however, no CFUs formed on plates. The swabs were substituted for non-selective media contact plates in Experiment 2. Although CFUs were reported after this experiment on three walls of the test chamber, two CFUs (of differing colour/morphology to
<italic>P</italic>
.
<italic>putida</italic>
KT2440) were also found on one wall before the experiment (after alcohol surface cleaning). However, these subsequently did not grow when streaked onto PIA and were assumed environmental contaminants. PIA contact plates were used in subsequent experiments to eliminate the need for a sub-culturing confirmatory step(s). The contact plates showed contrasting results depending on whether or not airflow was applied. Specifically, in Experiments 2 and 8, which were carried out with an applied upward airflow, CFUs appeared on plates which sampled from the top, right and front walls of the test chamber. By contrast, in Experiments 6 and 7, carried out with no induced airflow, CFUs were only found on the bottom surface sample. This confirms that even in the absence of an applied airflow, cross-transmission into the test chamber was achievable.</p>
<p>Three experiments (8, 9, and 10) were carried out incorporating a pre-sterilised toilet within the test chamber connected at the upper floor. Experiment 8 showed that with a partially filled U-trap, cross-contamination was apparent on the toilet itself, on the test chamber surfaces, and at the end of the flexible duct connected to the extract fan. On a surface area basis, the contact plates suggest the toilet contamination was higher than the test chamber and focused towards the front of the toilet bowl (position 3 in
<xref ref-type="fig" rid="pone.0171556.g005">Fig 5A</xref>
, see
<xref rid="pone.0171556.t002" ref-type="table">Table 2</xref>
) and, therefore, was probably influenced by the draw of the extract fan. In Experiments 9 and 10, a second novel passive sampler method was trialled involving a perforated plate placed at toilet seat height. After these experiments the perforated plate was over-turned and sampled using contact plates. However, the plate was wet after each experiment and likely to have affected the numbers of bacteria recovered from this surface; results are reported in
<xref rid="pone.0171556.t002" ref-type="table">Table 2</xref>
as presence/absence rather than actual numbers. As with the toilet surface sampler from Experiment 8, the perforated plate sampling suggested a focus towards the front of the toilet bowl (P10 and P11 in
<xref ref-type="fig" rid="pone.0171556.g005">Fig 5B</xref>
and
<xref rid="pone.0171556.t002" ref-type="table">Table 2</xref>
).</p>
<p>As well as passive air and surface sampling, an active air sampler was used to quantify bacteria transmitted through the entire system by positioning it at the exhaust termination of the flexible duct connected to the extract fan, see
<xref ref-type="fig" rid="pone.0171556.g003">Fig 3</xref>
. CFUs formed on PIA plates from all experiments using the active air sampler, confirming the cross-transmission of bacteria through the entire sanitary plumbing test-rig: from the flushing of contaminated wastewater at the lower floor and into the test chamber, as evidenced by the passive and surface sampling methods, and then into the extract ventilation system. Although CFU counts are given for the active air sampler in Tables
<xref rid="pone.0171556.t001" ref-type="table">1</xref>
and
<xref rid="pone.0171556.t002" ref-type="table">2</xref>
, these are considered as semi-quantitative for several reasons. Firstly, active air sampling was used in conjunction with passive sampling in several experiments (Experiments 2, 3, 4, 5, 9, and 10) which will have impacted on the number of cells flowing through the system. Secondly, the active air sampler had a fixed flow rate of 100 litres per minute (i.e. 1·67 ls
<sup>-1</sup>
) and was, therefore, considerably lower than the peak airflow rate within the test-rig (29·8 ls
<sup>-1</sup>
) meaning that cells will have been lost by bypassing the active air sampler. In addition to this, the different airflow velocity in the test-rig may have affected the sampling flow rate of the active air sampler and, therefore, impact velocity of the active air sampler itself. Assuming this was the case, a higher impact velocity (more than double the sampler’s optimal at the highest flow rate) could easily have resulted in lethal injury to bacterial cells and subsequent under reporting [
<xref rid="pone.0171556.ref023" ref-type="bibr">23</xref>
]. Finally, in Experiments 8 and 9, a high surface density of CFUs on the agar plate may have resulted in masking of colonies and subsequent under reporting [
<xref rid="pone.0171556.ref024" ref-type="bibr">24</xref>
].</p>
</sec>
<sec id="sec011">
<title>On-site observations of defective trap seals</title>
<p>Observation data from previously completed on-site research carried out over many years were collated and suggest that U-trap depletion is not uncommon.
<xref rid="pone.0171556.t003" ref-type="table">Table 3</xref>
below shows examples of buildings where the Authors have observed depleted U-traps or have been involved in efforts to alleviate recurring problems in specific buildings (these efforts include re-design of ventilation and pressure alleviation systems, and replacement of water traps with waterless, sheath versions). Depleted U-traps have been found in buildings in many countries and in many different types of building. It is important to note that the majority of these buildings are high occupancy and that two of the buildings observed to suffer from depleted U-traps in the UK are hospitals.</p>
<table-wrap id="pone.0171556.t003" orientation="portrait" position="float">
<object-id pub-id-type="doi">10.1371/journal.pone.0171556.t003</object-id>
<label>Table 3</label>
<caption>
<title>Observations of depleted U-traps within different locations and building types.</title>
</caption>
<alternatives>
<graphic id="pone.0171556.t003g" xlink:href="pone.0171556.t003"></graphic>
<table frame="hsides" rules="groups">
<colgroup span="1">
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
</colgroup>
<thead>
<tr>
<th align="left" rowspan="1" colspan="1">Location</th>
<th align="left" rowspan="1" colspan="1">Building type</th>
<th align="left" rowspan="1" colspan="1">No. of floors</th>
<th align="left" rowspan="1" colspan="1">U-trap location</th>
<th align="left" rowspan="1" colspan="1">Partially depleted</th>
<th align="left" rowspan="1" colspan="1">Fully depleted</th>
<th align="left" rowspan="1" colspan="1">Likely cause</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left" rowspan="1" colspan="1">UK</td>
<td align="left" rowspan="1" colspan="1">Hospital</td>
<td align="left" rowspan="1" colspan="1">5</td>
<td align="left" rowspan="1" colspan="1">Bathroom</td>
<td align="center" rowspan="1" colspan="1"></td>
<td align="center" rowspan="1" colspan="1"></td>
<td align="left" rowspan="1" colspan="1">Evaporation/ under use</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">UK</td>
<td align="left" rowspan="1" colspan="1">Hospital</td>
<td align="left" rowspan="1" colspan="1">5</td>
<td align="left" rowspan="1" colspan="1">Plant room</td>
<td align="center" rowspan="1" colspan="1"></td>
<td align="center" rowspan="1" colspan="1"></td>
<td align="left" rowspan="1" colspan="1">Evaporation/ under use</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">UK</td>
<td align="left" rowspan="1" colspan="1">University campus</td>
<td align="left" rowspan="1" colspan="1">5</td>
<td align="left" rowspan="1" colspan="1">Plant room</td>
<td align="center" rowspan="1" colspan="1"></td>
<td align="center" rowspan="1" colspan="1"></td>
<td align="left" rowspan="1" colspan="1">Evaporation/ under use</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">UK</td>
<td align="left" rowspan="1" colspan="1">Office building</td>
<td align="left" rowspan="1" colspan="1">8</td>
<td align="left" rowspan="1" colspan="1">Basement</td>
<td align="center" rowspan="1" colspan="1"></td>
<td align="center" rowspan="1" colspan="1"></td>
<td align="left" rowspan="1" colspan="1">Evaporation/ under use</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">Ireland</td>
<td align="left" rowspan="1" colspan="1">Residential</td>
<td align="left" rowspan="1" colspan="1">1</td>
<td align="left" rowspan="1" colspan="1">Bathroom</td>
<td align="center" rowspan="1" colspan="1"></td>
<td align="center" rowspan="1" colspan="1"></td>
<td align="left" rowspan="1" colspan="1">Evaporation/ under use</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">USA</td>
<td align="left" rowspan="1" colspan="1">Hotel</td>
<td align="left" rowspan="1" colspan="1">10</td>
<td align="left" rowspan="1" colspan="1">Bathroom</td>
<td align="center" rowspan="1" colspan="1"></td>
<td align="center" rowspan="1" colspan="1"></td>
<td align="left" rowspan="1" colspan="1">Pressure transients</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">China</td>
<td align="left" rowspan="1" colspan="1">Office building</td>
<td align="left" rowspan="1" colspan="1">7</td>
<td align="left" rowspan="1" colspan="1">Public toilets</td>
<td align="center" rowspan="1" colspan="1">ID</td>
<td align="center" rowspan="1" colspan="1"></td>
<td align="left" rowspan="1" colspan="1">Pressure transients</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">Hong Kong</td>
<td align="left" rowspan="1" colspan="1">Residential</td>
<td align="left" rowspan="1" colspan="1">50</td>
<td align="left" rowspan="1" colspan="1">Bathroom</td>
<td align="center" rowspan="1" colspan="1"></td>
<td align="center" rowspan="1" colspan="1"></td>
<td align="left" rowspan="1" colspan="1">Evaporation/ under use</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">UK</td>
<td align="left" rowspan="1" colspan="1">Hospital</td>
<td align="left" rowspan="1" colspan="1">7</td>
<td align="left" rowspan="1" colspan="1">Wards</td>
<td align="center" rowspan="1" colspan="1"></td>
<td align="center" rowspan="1" colspan="1"></td>
<td align="left" rowspan="1" colspan="1">Unknown</td>
</tr>
</tbody>
</table>
</alternatives>
<table-wrap-foot>
<fn id="t003fn001">
<p>ID = Intermittent depletion.</p>
</fn>
</table-wrap-foot>
</table-wrap>
</sec>
</sec>
<sec sec-type="conclusions" id="sec012">
<title>Discussion</title>
<p>The experiments prove that pathogens can be transmitted from one part of a building to another on sanitary plumbing system airstreams.</p>
<p>The U-trap is designed to provide a physical barrier between the sanitary plumbing system and building in order to prevent cross-transmission of airstreams. However, it is vulnerable to particular environmental and system conditions that make it susceptible to depletion.
<xref rid="pone.0171556.t004" ref-type="table">Table 4</xref>
details the hazards that influence the risk of U-trap depletion.</p>
<table-wrap id="pone.0171556.t004" orientation="portrait" position="float">
<object-id pub-id-type="doi">10.1371/journal.pone.0171556.t004</object-id>
<label>Table 4</label>
<caption>
<title>Hazards of water trap seal depletion.</title>
</caption>
<alternatives>
<graphic id="pone.0171556.t004g" xlink:href="pone.0171556.t004"></graphic>
<table frame="hsides" rules="groups">
<colgroup span="1">
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
<col align="left" valign="middle" span="1"></col>
</colgroup>
<thead>
<tr>
<th align="left" rowspan="1" colspan="1">Hazard</th>
<th align="left" rowspan="1" colspan="1">Risk to U-trap</th>
<th align="left" rowspan="1" colspan="1">Cause</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left" rowspan="1" colspan="1">Under-use</td>
<td align="left" rowspan="1" colspan="1">Evaporation</td>
<td align="left" rowspan="1" colspan="1">Vacant/under-utilised building</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">High ambient temperature</td>
<td align="left" rowspan="1" colspan="1">Increased rate of evaporation</td>
<td align="left" rowspan="1" colspan="1">Local climate</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1"> </td>
<td align="left" rowspan="1" colspan="1"> </td>
<td align="left" rowspan="1" colspan="1">Internal heat gains</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1"></td>
<td align="left" rowspan="1" colspan="1"> </td>
<td align="left" rowspan="1" colspan="1">Poor design or construction</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1"> </td>
<td align="left" rowspan="1" colspan="1"> </td>
<td align="left" rowspan="1" colspan="1">Over-loaded system</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">Excessive system</td>
<td align="left" rowspan="1" colspan="1">Self- siphonage or</td>
<td align="left" rowspan="1" colspan="1">Tall building
<italic>(> 30 storeys)</italic>
</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1">pressure transients</td>
<td align="left" rowspan="1" colspan="1">induced-siphonage</td>
<td align="left" rowspan="1" colspan="1">External air pressures</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1"> </td>
<td align="left" rowspan="1" colspan="1"> </td>
<td align="left" rowspan="1" colspan="1">(wind shear/sewer surcharge)</td>
</tr>
<tr>
<td align="left" rowspan="1" colspan="1"> </td>
<td align="left" rowspan="1" colspan="1"> </td>
<td align="left" rowspan="1" colspan="1">Chimney effect</td>
</tr>
</tbody>
</table>
</alternatives>
</table-wrap>
<p>If an appliance is under-used then the water seal within the U-trap can simply evaporate over time. The rate of evaporation under normal ambient conditions in the UK has been found to be in the region of 3 mm per week [
<xref rid="pone.0171556.ref025" ref-type="bibr">25</xref>
]. A 50 mm water seal would, therefore, fail after a period of 17 weeks of non-use. Increased rates of evaporation occur due to higher ambient temperatures. Anecdotal evidence gathered by the authors has found that the water within a 50 mm floor gulley trap located within a boiler room evaporated completely within a 24 hour period.</p>
<p>The water seal is also vulnerable to fluctuations in air pressure that can propagate throughout the system as pressure transients. Excessive negative pressures generated by discharging appliances or adjacent appliances, can lead to trap depletion by self-siphonage or induced-siphonage, respectively. The propagation of excessive positive pressures within the system can be large enough to completely displace the water seal into the appliance [
<xref rid="pone.0171556.ref026" ref-type="bibr">26</xref>
,
<xref rid="pone.0171556.ref027" ref-type="bibr">27</xref>
,
<xref rid="pone.0171556.ref028" ref-type="bibr">28</xref>
], leaving the trap either wholly or partially depleted. In some cases, even though the trap is not noticeably depleted, positive pressures can push air from the sanitary plumbing system through the water seal as air bubbles and into the building. Excessive system pressure transients can be caused due to poor design and/or construction, or when a system is simply over-loaded. They are also prevalent in tall buildings as design guides tend to have limited understanding of sanitary plumbing system operation in buildings over 30 storeys. External factors, such as wind shear over the stack termination and sewer surcharge, can also generate excessive pressure transients capable of depleting the water seal.</p>
<p>Since a U-trap is effectively a manometer, the important parameter relating to its retention is the water seal depth (not volume of water). A typical water seal depth for a sink, bath, shower is 50 mm and for a toilet it is 75 mm (in some hospital isolation wards these can be as large as 200 mm) Therefore a negative pressure in excess of 50 mm water gauge (wg) will suck water out of a sink U-trap causing a direct breach of the seal between the sanitary foul system side and the room and a positive pressure wave in excess of 50 mm will blow through into the room via a sink. In some cases partial depletion or partial flow through (bubble through) can occur which allows foul air to enter the room while the U-trap may look intact afterwards. Limiting pressure fluctuations forms the basis of much of the design of a sanitary plumbing network and while great efforts are made to reduce the likelihood of this, transient generation and propagation is inevitable (particularly in larger systems where overload is possible). Air pressure surges in excess of 50 mm (both negative and positive) are not uncommon and while efforts are made to limit these by introduce air admittance valves and P.A.P.A’s into the system, localised pressure surges and hence depleted U-traps, are inevitable on large systems[
<xref rid="pone.0171556.ref005" ref-type="bibr">5</xref>
,
<xref rid="pone.0171556.ref026" ref-type="bibr">26</xref>
,
<xref rid="pone.0171556.ref027" ref-type="bibr">27</xref>
,
<xref rid="pone.0171556.ref028" ref-type="bibr">28</xref>
].</p>
<p>The likelihood of a building occupant becoming infected through transmission from the sanitary plumbing system is dependent on four main variables: (i) the presence of a depleted U-trap; (ii) the presence of infectious pathogens within the sanitary plumbing system; (iii) adequate system airflows to transmit the infectious pathogens; and (iv) the susceptibility of the occupant to those infectious pathogens, heightened due to immunity suppression. The likelihood of infection is increased by the affirmative presence of each risk factor, see
<xref ref-type="fig" rid="pone.0171556.g006">Fig 6</xref>
. Taking Amoy Gardens as an example, the presence of depleted U-traps, the presence of the SARS virus within the sanitary plumbing system, sufficient airflows to transmit the virus to adjacent apartments, but no residents with a suppressed immunity shows, in that situation, the transmission of SARS was likely.</p>
<fig id="pone.0171556.g006" orientation="portrait" position="float">
<object-id pub-id-type="doi">10.1371/journal.pone.0171556.g006</object-id>
<label>Fig 6</label>
<caption>
<title>Transmission of infection from sanitary plumbing systems: risk factors and likelihood (adapted from OECD, 2005 [
<xref rid="pone.0171556.ref029" ref-type="bibr">29</xref>
]).</title>
</caption>
<graphic xlink:href="pone.0171556.g006"></graphic>
</fig>
</sec>
<sec sec-type="conclusions" id="sec013">
<title>Conclusions</title>
<p>The conclusions from our work are;</p>
<list list-type="bullet">
<list-item>
<p>Under defect conditions a transmission route exists within the sanitary plumbing system which could allow pathogens to move from one part of a building to another.</p>
</list-item>
<list-item>
<p>Our experiments in a full-scale pilot test-rig of a 2 storey sanitary plumbing system showed that the turbulence caused by a toilet discharge was sufficient to aerosolise a model organism (
<italic>P</italic>
.
<italic>putida</italic>
) which was then carried on airstreams and contaminated pipework, toilet bowl, room surfaces and extract fan system.</p>
</list-item>
<list-item>
<p>The passive sampling techniques developed in this research were effective as a semi-quantitative approach for the sampling of a model organism in an airflow.</p>
</list-item>
<list-item>
<p>The air flow rates used in these experiments were typical of those found in real buildings. Our findings indicate that whilst the extent of organism transport was negligible when there was no induced upward airflow, cross-transmission between floors did occur for all experiments where there was an induced airflow (>16.73 ls
<sup>-1</sup>
).</p>
</list-item>
<list-item>
<p>We have developed a qualitative risk assessment tool for building managers and maintenance personnel to use in order to assess the risk of a person becoming ill as a result of this mode of cross transmission.</p>
</list-item>
</list>
</sec>
</body>
<back>
<ref-list>
<title>References</title>
<ref id="pone.0171556.ref001">
<label>1</label>
<mixed-citation publication-type="book">
<name>
<surname>Moore</surname>
<given-names>G</given-names>
</name>
and
<name>
<surname>Walker</surname>
<given-names>JT</given-names>
</name>
.
<chapter-title>Presence and control of Legionella pneumophila and Pseudomonas aeruginosa biofilms in hospital water systems</chapter-title>
in:
<name>
<surname>Percival</surname>
<given-names>SL</given-names>
</name>
,
<name>
<surname>Randle</surname>
<given-names>J</given-names>
</name>
,
<name>
<surname>Cooper</surname>
<given-names>T</given-names>
</name>
and
<name>
<surname>Williams</surname>
<given-names>D</given-names>
</name>
. (Eds.)
<source>Biofilms in Infection Prevention and Control–A Healthcare Handbook</source>
.
<publisher-name>Elsevier</publisher-name>
:
<year>2013</year>
.</mixed-citation>
</ref>
<ref id="pone.0171556.ref002">
<label>2</label>
<mixed-citation publication-type="other">CIBSE. TM13 Minimising the Risk of Legionnaires' Disease. 2013.</mixed-citation>
</ref>
<ref id="pone.0171556.ref003">
<label>3</label>
<mixed-citation publication-type="other">ANSI/ASHRAE Legionellosis: Risk Management for Building Water Systems.
<italic>Standard</italic>
188–2015.</mixed-citation>
</ref>
<ref id="pone.0171556.ref004">
<label>4</label>
<mixed-citation publication-type="journal">
<name>
<surname>Moore</surname>
<given-names>G</given-names>
</name>
,
<name>
<surname>Stevenson</surname>
<given-names>D</given-names>
</name>
,
<name>
<surname>Thompson</surname>
<given-names>K-A</given-names>
</name>
,
<name>
<surname>Parks</surname>
<given-names>S</given-names>
</name>
,
<name>
<surname>Ngabo</surname>
<given-names>D</given-names>
</name>
,
<name>
<surname>Bennett</surname>
<given-names>AM</given-names>
</name>
<etal>et al</etal>
<article-title>Biofilm formation in an experimental water distribution system: the contamination of non-touch sensor taps and the implication for healthcare.</article-title>
<source>Biofouling</source>
.
<year>2015</year>
;
<volume>31</volume>
:
<fpage>677</fpage>
<lpage>687</lpage>
.
<pub-id pub-id-type="doi">10.1080/08927014.2015.1089986</pub-id>
<pub-id pub-id-type="pmid">26652665</pub-id>
</mixed-citation>
</ref>
<ref id="pone.0171556.ref005">
<label>5</label>
<mixed-citation publication-type="journal">
<name>
<surname>Walker</surname>
<given-names>JT</given-names>
</name>
and
<name>
<surname>Moore</surname>
<given-names>G.</given-names>
</name>
<article-title>Pseudomonas aeruginosa—biofilms, guidelines and practicalities</article-title>
.
<source>Journal of Hospital Infection</source>
,
<year>2015</year>
;
<volume>89</volume>
:
<fpage>324</fpage>
<lpage>327</lpage>
.
<pub-id pub-id-type="doi">10.1016/j.jhin.2014.11.019</pub-id>
<pub-id pub-id-type="pmid">25623205</pub-id>
</mixed-citation>
</ref>
<ref id="pone.0171556.ref006">
<label>6</label>
<mixed-citation publication-type="journal">
<name>
<surname>Pitts</surname>
<given-names>B</given-names>
</name>
,
<name>
<surname>Stewart</surname>
<given-names>PS</given-names>
</name>
,
<name>
<surname>McFeters</surname>
<given-names>GA</given-names>
</name>
,
<name>
<surname>Hamilton</surname>
<given-names>MA</given-names>
</name>
,
<name>
<surname>Willse</surname>
<given-names>A</given-names>
</name>
,
<name>
<surname>Zelver</surname>
<given-names>N</given-names>
</name>
.
<article-title>Bacterial characterization of toilet bowl biofilm</article-title>
,
<year>1998</year>
<source>Biofouling</source>
;
<volume>13</volume>
(
<issue>1</issue>
):
<fpage>19</fpage>
<lpage>30</lpage>
.</mixed-citation>
</ref>
<ref id="pone.0171556.ref007">
<label>7</label>
<mixed-citation publication-type="journal">
<name>
<surname>Gebra</surname>
<given-names>CP</given-names>
</name>
,
<name>
<surname>Wallis</surname>
<given-names>C</given-names>
</name>
and
<name>
<surname>Melnick</surname>
<given-names>JL</given-names>
</name>
.
<article-title>Microbiological hazards of household toilets: droplet production and the fate of residual organisms</article-title>
.
<source>Applied Environmental Microbiology</source>
,
<year>1975</year>
;
<volume>30</volume>
:
<fpage>229</fpage>
<lpage>237</lpage>
.</mixed-citation>
</ref>
<ref id="pone.0171556.ref008">
<label>8</label>
<mixed-citation publication-type="journal">
<name>
<surname>Barker</surname>
<given-names>J</given-names>
</name>
and
<name>
<surname>Jones</surname>
<given-names>MV</given-names>
</name>
.
<article-title>The potential spread of infection caused by aerosol contamination of surfaces after flushing a domestic toilet</article-title>
.
<source>Journal of Applied Microbiology</source>
,
<year>2005</year>
;
<volume>99</volume>
(
<issue>2</issue>
):
<fpage>339</fpage>
<lpage>347</lpage>
.
<pub-id pub-id-type="doi">10.1111/j.1365-2672.2005.02610.x</pub-id>
<pub-id pub-id-type="pmid">16033465</pub-id>
</mixed-citation>
</ref>
<ref id="pone.0171556.ref009">
<label>9</label>
<mixed-citation publication-type="journal">
<name>
<surname>Barker</surname>
<given-names>J</given-names>
</name>
and
<name>
<surname>Bloomfield</surname>
<given-names>S.</given-names>
</name>
<article-title>F Survival of Salmonella in bathrooms and toilets in domestic homes following salmonellosis</article-title>
<source>Journal of applied Microbiology</source>
,
<year>2000</year>
;
<volume>89</volume>
:
<fpage>137</fpage>
<lpage>144</lpage>
.
<pub-id pub-id-type="pmid">10945790</pub-id>
</mixed-citation>
</ref>
<ref id="pone.0171556.ref010">
<label>10</label>
<mixed-citation publication-type="journal">
<name>
<surname>Riley</surname>
<given-names>S</given-names>
</name>
,
<name>
<surname>Fraser</surname>
<given-names>C</given-names>
</name>
,
<name>
<surname>Donnelly</surname>
<given-names>CA</given-names>
</name>
,
<name>
<surname>Ghani</surname>
<given-names>AC</given-names>
</name>
,
<name>
<surname>Abu-Radda</surname>
<given-names>LJ</given-names>
</name>
,
<name>
<surname>Hedley</surname>
<given-names>AJ</given-names>
</name>
<etal>et al</etal>
<article-title>Transmission dynamics of the etiological agent of SARS in Hong Kong: Impact of public health interventions</article-title>
.
<source>Science</source>
,
<year>2003</year>
;
<volume>300</volume>
:
<fpage>1961</fpage>
<lpage>1966</lpage>
.
<pub-id pub-id-type="doi">10.1126/science.1086478</pub-id>
<pub-id pub-id-type="pmid">12766206</pub-id>
</mixed-citation>
</ref>
<ref id="pone.0171556.ref011">
<label>11</label>
<mixed-citation publication-type="book">
<collab>WHO</collab>
.
<chapter-title>Consensus document on the epidemiology of severe acute respiratory syndrome (SARS)</chapter-title>
<source>Department of Communicable Disease Surveillance and Response</source>
,
<publisher-name>World Health Organisation</publisher-name>
,
<year>2003</year>
.</mixed-citation>
</ref>
<ref id="pone.0171556.ref012">
<label>12</label>
<mixed-citation publication-type="journal">
<name>
<surname>Tang</surname>
<given-names>JW</given-names>
</name>
,
<name>
<surname>Noakes</surname>
<given-names>CJ</given-names>
</name>
,
<name>
<surname>Nielson</surname>
<given-names>PV</given-names>
</name>
,
<name>
<surname>Eames</surname>
<given-names>I</given-names>
</name>
,
<name>
<surname>Nicolle</surname>
<given-names>A</given-names>
</name>
,
<name>
<surname>Li</surname>
<given-names>Y</given-names>
</name>
<etal>et al.</etal>
<article-title>Observing and quantifying airflows in the infection control of aerosol- and airborne-transmitted diseases: an overview of approaches</article-title>
.
<source>Journal of Hospital Infections</source>
<year>2011</year>
;
<volume>77</volume>
:
<fpage>213</fpage>
<lpage>222</lpage>
.</mixed-citation>
</ref>
<ref id="pone.0171556.ref013">
<label>13</label>
<mixed-citation publication-type="journal">
<name>
<surname>Hathway</surname>
<given-names>EA</given-names>
</name>
,
<name>
<surname>Noakes</surname>
<given-names>CJ</given-names>
</name>
,
<name>
<surname>Sleigh</surname>
<given-names>PA</given-names>
</name>
,
<name>
<surname>Fletcher</surname>
<given-names>LA</given-names>
</name>
<article-title>CFD simulation of airborne pathogen transport due to human activities</article-title>
.
<source>Building and Environment</source>
,
<year>2011</year>
;
<volume>46</volume>
:
<fpage>2500</fpage>
<lpage>2511</lpage>
.</mixed-citation>
</ref>
<ref id="pone.0171556.ref014">
<label>14</label>
<mixed-citation publication-type="journal">
<name>
<surname>Hung</surname>
<given-names>HCK</given-names>
</name>
,
<name>
<surname>Chan</surname>
<given-names>DWT</given-names>
</name>
,
<name>
<surname>Law</surname>
<given-names>LKC</given-names>
</name>
,
<name>
<surname>Chan</surname>
<given-names>EHW</given-names>
</name>
and
<name>
<surname>Wong</surname>
<given-names>ESW</given-names>
</name>
.
<article-title>Industrial experience and research into the causes of SARS virus transmission in a high-rie residential housing estate in Hong Kong</article-title>
,
<source>Building Services Engineering Research and Technology</source>
,
<year>2006</year>
;
<volume>27</volume>
(
<issue>2</issue>
):
<fpage>91</fpage>
<lpage>102</lpage>
.</mixed-citation>
</ref>
<ref id="pone.0171556.ref015">
<label>15</label>
<mixed-citation publication-type="journal">
<name>
<surname>Gormley</surname>
<given-names>M</given-names>
</name>
,
<name>
<surname>Swaffield</surname>
<given-names>JA</given-names>
</name>
,
<name>
<surname>Sleigh</surname>
<given-names>PA</given-names>
</name>
and
<name>
<surname>Noakes</surname>
<given-names>CJ</given-names>
</name>
.
<article-title>An assessment of, and response to, potential cross contamination routes due to defective appliance water trap seals in building drainage systems</article-title>
.
<source>Building Services Engineering Research and Technology</source>
,
<year>2012</year>
;
<volume>33</volume>
:
<fpage>203</fpage>
<lpage>222</lpage>
.</mixed-citation>
</ref>
<ref id="pone.0171556.ref016">
<label>16</label>
<mixed-citation publication-type="other">British Standards Institution. BS EN 12056–2 Gravity drainage systems inside buildings. Sanitary pipework, layout and calculation. 2000: British Standards Institute.</mixed-citation>
</ref>
<ref id="pone.0171556.ref017">
<label>17</label>
<mixed-citation publication-type="book">
<name>
<surname>Swaffield</surname>
<given-names>J.</given-names>
</name>
,
<name>
<surname>Gormley</surname>
<given-names>M</given-names>
</name>
.,
<name>
<surname>Wright</surname>
<given-names>G</given-names>
</name>
&
<name>
<surname>McDougall</surname>
<given-names>I</given-names>
</name>
.
<source>Transient Free Surface Flows in Building Drainage Systems</source>
,
<year>2015</year>
,
<publisher-name>Routledge</publisher-name>
,
<publisher-loc>Oxon</publisher-loc>
. ISBN: 978-0-415-58915-4 (hbk) ISBN: 978-0-203-84576-9 (ebk).</mixed-citation>
</ref>
<ref id="pone.0171556.ref018">
<label>18</label>
<mixed-citation publication-type="other">Swaffield, J. Transient Airflows in Building Drainage Systems. 2010, London, New York, Spon.</mixed-citation>
</ref>
<ref id="pone.0171556.ref019">
<label>19</label>
<mixed-citation publication-type="other">Gormley M, Kelly DA and Aspray TJ. Bio-aerosol cross-transmission via the building drainage system
<italic>Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate</italic>
. International Society of Indoor Air Quality and Climate: 132–139.</mixed-citation>
</ref>
<ref id="pone.0171556.ref020">
<label>20</label>
<mixed-citation publication-type="journal">
<name>
<surname>Gormley</surname>
<given-names>M</given-names>
</name>
,
<name>
<surname>Templeton</surname>
<given-names>K</given-names>
</name>
,
<name>
<surname>Kelly</surname>
<given-names>DA</given-names>
</name>
and
<name>
<surname>Hardie</surname>
<given-names>A</given-names>
</name>
.
<article-title>Environmental conditions and the prevalence of norovirus in hospital building drainage system wastewater and airflows</article-title>
.
<source>Building Services Engineering Research and Technology</source>
,
<year>2013</year>
;
<volume>35</volume>
(
<issue>3</issue>
):
<fpage>244</fpage>
<lpage>253</lpage>
.</mixed-citation>
</ref>
<ref id="pone.0171556.ref021">
<label>21</label>
<mixed-citation publication-type="journal">
<name>
<surname>Aspray</surname>
<given-names>TJ</given-names>
</name>
,
<name>
<surname>Hansen</surname>
<given-names>SK</given-names>
</name>
,
<name>
<surname>Burns</surname>
<given-names>RG</given-names>
</name>
.
<article-title>A soil-based microbial biofilm exposed to 2,4-D: bacterial community development and establishment of conjugative plasmid pJP4</article-title>
.
<source>FEMS Microbiology Ecology</source>
,
<year>2005</year>
;
<volume>54</volume>
(
<issue>2</issue>
):
<fpage>317</fpage>
<lpage>327</lpage>
.
<pub-id pub-id-type="doi">10.1016/j.femsec.2005.04.007</pub-id>
<pub-id pub-id-type="pmid">16332330</pub-id>
</mixed-citation>
</ref>
<ref id="pone.0171556.ref022">
<label>22</label>
<mixed-citation publication-type="other">British Standards Institute. BS EN ISO 14698–1:2003 Cleanrooms and associated controlled environments. Biocontamination control. General principles and methods, 2003; British Standards Institute, London.</mixed-citation>
</ref>
<ref id="pone.0171556.ref023">
<label>23</label>
<mixed-citation publication-type="journal">
<name>
<surname>Stewart</surname>
<given-names>SL</given-names>
</name>
,
<name>
<surname>Grinshpun</surname>
<given-names>SA</given-names>
</name>
,
<name>
<surname>Willeke</surname>
<given-names>K</given-names>
</name>
,
<name>
<surname>Terzieva</surname>
<given-names>S</given-names>
</name>
,
<name>
<surname>Ulevicius</surname>
<given-names>V</given-names>
</name>
,
<name>
<surname>Donnelly</surname>
<given-names>J</given-names>
</name>
(1995)
<article-title>Effect of impact stress on microbial recovery on an agar surface</article-title>
.
<source>Applied and Environmental Microbiology</source>
,
<year>1995</year>
;
<volume>61</volume>
(
<issue>4</issue>
):
<fpage>1232</fpage>
<lpage>1239</lpage>
.
<pub-id pub-id-type="pmid">7747946</pub-id>
</mixed-citation>
</ref>
<ref id="pone.0171556.ref024">
<label>24</label>
<mixed-citation publication-type="journal">
<name>
<surname>Chang</surname>
<given-names>CW</given-names>
</name>
,
<name>
<surname>Hwang</surname>
<given-names>YH</given-names>
</name>
,
<name>
<surname>Grinshpun</surname>
<given-names>SA</given-names>
</name>
,
<name>
<surname>Macher</surname>
<given-names>JA</given-names>
</name>
,
<name>
<surname>Willeke</surname>
<given-names>K</given-names>
</name>
.
<article-title>Evaluation of counting error due to colony masking in bioaerosol sampling</article-title>
.
<source>Applied and Environmental Microbiology</source>
,
<year>1994</year>
;
<volume>60</volume>
:
<fpage>3732</fpage>
<lpage>3738</lpage>
.
<pub-id pub-id-type="pmid">7986046</pub-id>
</mixed-citation>
</ref>
<ref id="pone.0171556.ref025">
<label>25</label>
<mixed-citation publication-type="book">
<name>
<surname>Wise</surname>
<given-names>AFE</given-names>
</name>
and
<name>
<surname>Swaffield</surname>
<given-names>JA</given-names>
</name>
.
<source>Water, sanitary and waste services for buildings</source>
,
<edition>4th Edition</edition>
,
<publisher-name>Longman Scientific and Technical</publisher-name>
,
<year>1995</year>
,
<publisher-loc>London</publisher-loc>
.</mixed-citation>
</ref>
<ref id="pone.0171556.ref026">
<label>26</label>
<mixed-citation publication-type="journal">
<name>
<surname>Swaffield</surname>
<given-names>JA</given-names>
</name>
,
<name>
<surname>Campbell</surname>
<given-names>DP</given-names>
</name>
and
<name>
<surname>Gormley</surname>
<given-names>M</given-names>
</name>
.
<article-title>Pressure Transient Control Part I—Criteria for Transient Analysis and Control</article-title>
<source>Building Services Engineering Research and Technology</source>
,
<year>2005</year>
;
<volume>26</volume>
(
<issue>2</issue>
)
<fpage>99</fpage>
<lpage>114</lpage>
.</mixed-citation>
</ref>
<ref id="pone.0171556.ref027">
<label>27</label>
<mixed-citation publication-type="journal">
<name>
<surname>Swaffield</surname>
<given-names>JA</given-names>
</name>
,
<name>
<surname>Campbell</surname>
<given-names>DP</given-names>
</name>
, and
<name>
<surname>Gormley</surname>
<given-names>M</given-names>
</name>
.
<article-title>Pressure Transient Control Part II—simulation and design of a positive surge protection device for building drainage networks</article-title>
,
<source>Building Services Engineering Research and Technology</source>
,
<year>2005</year>
;
<volume>26</volume>
(
<issue>3</issue>
):
<fpage>195</fpage>
<lpage>212</lpage>
.</mixed-citation>
</ref>
<ref id="pone.0171556.ref028">
<label>28</label>
<mixed-citation publication-type="journal">
<name>
<surname>Gormley</surname>
<given-names>M.</given-names>
</name>
(2007)
<article-title>Air pressure transient generation as a result of falling solids in building drainage stacks: definition, mechanisms and modelling</article-title>
.
<source>Building Services Engineering Research & Technology</source>
,
<year>2007</year>
;
<volume>28</volume>
(
<issue>1</issue>
):
<fpage>55</fpage>
<lpage>70</lpage>
.</mixed-citation>
</ref>
<ref id="pone.0171556.ref029">
<label>29</label>
<mixed-citation publication-type="book">
<collab>OECD</collab>
(
<year>2005</year>
),
<source>
<italic toggle="yes">Lessons in Danger</italic>
, School Safety and Security</source>
,
<publisher-name>OECD Publishing</publisher-name>
,
<publisher-loc>Paris</publisher-loc>
.</mixed-citation>
</ref>
</ref-list>
</back>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Sante/explor/SrasV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001352 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 001352 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Sante
   |area=    SrasV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:5302810
   |texte=   Pathogen cross-transmission via building sanitary plumbing systems in a full scale pilot test-rig
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:28187135" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a SrasV1 

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Tue Apr 28 14:49:16 2020. Site generation: Sat Mar 27 22:06:49 2021