Development and application of an integrated indoor air quality audit to an international hotel building in Taiwan
Identifieur interne : 003A33 ( Main/Exploration ); précédent : 003A32; suivant : 003A34Development and application of an integrated indoor air quality audit to an international hotel building in Taiwan
Auteurs : Nae-Wen Kuo [République populaire de Chine, Taïwan] ; Hsin-Chen Chiang [République populaire de Chine] ; Che-Ming Chiang [République populaire de Chine]Source :
- Environmental Monitoring and Assessment [ 0167-6369 ] ; 2008-12-01.
English descriptors
Abstract
Abstract: Indoor air quality (IAQ) has begun to surface as an important issue that affects the comfort and health of people; however, there is little research concerned about the IAQ monitoring of hotels up to now. Hotels are designed to provide comfortable spaces for guests. However, most complaints related to uncomfortable thermal environment and inadequate indoor air quality appear. In addition, microbial pollution can affect the health of tourists such as the Legionnaire’s disease and SARS problems. This study is aimed to establish the comprehensive IAQ audit approach for hotel buildings with portable equipments, and one five-star international hotel in Taiwan was selected to exam this integrated approach. Finally, four major problems are identified after the comprehensive IAQ audit. They are: (1) low room temperature (21.8°C), (2) insufficient air exchange rate (<1.5 h−1), (3) formaldehyde contamination (>0.02 ppm), and (4) the microbial pollution (total bacteria: 2,624–3,799 CFU/m3). The high level of formaldehyde may be due to the emission from the detergent and cleaning agents used for housekeeping.
Url:
DOI: 10.1007/s10661-007-0105-5
Affiliations:
Links toward previous steps (curation, corpus...)
- to stream Istex, to step Corpus: 000E96
- to stream Istex, to step Curation: 000E96
- to stream Istex, to step Checkpoint: 001377
- to stream Main, to step Merge: 003B88
- to stream Main, to step Curation: 003A33
Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title xml:lang="en">Development and application of an integrated indoor air quality audit to an international hotel building in Taiwan</title>
<author><name sortKey="Kuo, Nae Wen" sort="Kuo, Nae Wen" uniqKey="Kuo N" first="Nae-Wen" last="Kuo">Nae-Wen Kuo</name>
</author>
<author><name sortKey="Chiang, Hsin Chen" sort="Chiang, Hsin Chen" uniqKey="Chiang H" first="Hsin-Chen" last="Chiang">Hsin-Chen Chiang</name>
</author>
<author><name sortKey="Chiang, Che Ming" sort="Chiang, Che Ming" uniqKey="Chiang C" first="Che-Ming" last="Chiang">Che-Ming Chiang</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:5CB5AFED8FDF45698D30F4EA2E0E5DCF1B11E624</idno>
<date when="2007" year="2007">2007</date>
<idno type="doi">10.1007/s10661-007-0105-5</idno>
<idno type="url">https://api.istex.fr/ark:/67375/VQC-L4F04P53-4/fulltext.pdf</idno>
<idno type="wicri:Area/Istex/Corpus">000E96</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">000E96</idno>
<idno type="wicri:Area/Istex/Curation">000E96</idno>
<idno type="wicri:Area/Istex/Checkpoint">001377</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">001377</idno>
<idno type="wicri:doubleKey">0167-6369:2007:Kuo N:development:and:application</idno>
<idno type="wicri:Area/Main/Merge">003B88</idno>
<idno type="wicri:Area/Main/Curation">003A33</idno>
<idno type="wicri:Area/Main/Exploration">003A33</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a" type="main" xml:lang="en">Development and application of an integrated indoor air quality audit to an international hotel building in Taiwan</title>
<author><name sortKey="Kuo, Nae Wen" sort="Kuo, Nae Wen" uniqKey="Kuo N" first="Nae-Wen" last="Kuo">Nae-Wen Kuo</name>
<affiliation wicri:level="1"><country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Graduate Institute of Tourism and Health Science, National Taipei College of Nursing, P.O. Box 22-96, 10699, Taipei City, Taiwan</wicri:regionArea>
<wicri:noRegion>Taiwan</wicri:noRegion>
</affiliation>
<affiliation wicri:level="1"><country wicri:rule="url">Taïwan</country>
</affiliation>
</author>
<author><name sortKey="Chiang, Hsin Chen" sort="Chiang, Hsin Chen" uniqKey="Chiang H" first="Hsin-Chen" last="Chiang">Hsin-Chen Chiang</name>
<affiliation wicri:level="1"><country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Graduate Institute of Tourism and Health Science, National Taipei College of Nursing, P.O. Box 22-96, 10699, Taipei City, Taiwan</wicri:regionArea>
<wicri:noRegion>Taiwan</wicri:noRegion>
</affiliation>
</author>
<author><name sortKey="Chiang, Che Ming" sort="Chiang, Che Ming" uniqKey="Chiang C" first="Che-Ming" last="Chiang">Che-Ming Chiang</name>
<affiliation wicri:level="1"><country xml:lang="fr">République populaire de Chine</country>
<wicri:regionArea>Department of Architecture, National Cheng Kung University, No. 1, University Road, Tainan City, Taiwan</wicri:regionArea>
<wicri:noRegion>Taiwan</wicri:noRegion>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j">Environmental Monitoring and Assessment</title>
<title level="j" type="sub">An International Journal Devoted to Progress in the Use of Monitoring Data in Assessing Environmental Risks to Man and the Environment</title>
<title level="j" type="abbrev">Environ Monit Assess</title>
<idno type="ISSN">0167-6369</idno>
<idno type="eISSN">1573-2959</idno>
<imprint><publisher>Springer Netherlands</publisher>
<pubPlace>Dordrecht</pubPlace>
<date type="published" when="2008-12-01">2008-12-01</date>
<biblScope unit="volume">147</biblScope>
<biblScope unit="issue">1-3</biblScope>
<biblScope unit="page" from="139">139</biblScope>
<biblScope unit="page" to="147">147</biblScope>
</imprint>
<idno type="ISSN">0167-6369</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0167-6369</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass><keywords scheme="KwdEn" xml:lang="en"><term>Hotel building</term>
<term>Indoor air quality (IAQ)</term>
<term>Tourist health</term>
</keywords>
</textClass>
<langUsage><language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front><div type="abstract" xml:lang="en">Abstract: Indoor air quality (IAQ) has begun to surface as an important issue that affects the comfort and health of people; however, there is little research concerned about the IAQ monitoring of hotels up to now. Hotels are designed to provide comfortable spaces for guests. However, most complaints related to uncomfortable thermal environment and inadequate indoor air quality appear. In addition, microbial pollution can affect the health of tourists such as the Legionnaire’s disease and SARS problems. This study is aimed to establish the comprehensive IAQ audit approach for hotel buildings with portable equipments, and one five-star international hotel in Taiwan was selected to exam this integrated approach. Finally, four major problems are identified after the comprehensive IAQ audit. They are: (1) low room temperature (21.8°C), (2) insufficient air exchange rate (<1.5 h−1), (3) formaldehyde contamination (>0.02 ppm), and (4) the microbial pollution (total bacteria: 2,624–3,799 CFU/m3). The high level of formaldehyde may be due to the emission from the detergent and cleaning agents used for housekeeping.</div>
</front>
</TEI>
<affiliations><list><country><li>République populaire de Chine</li>
<li>Taïwan</li>
</country>
</list>
<tree><country name="République populaire de Chine"><noRegion><name sortKey="Kuo, Nae Wen" sort="Kuo, Nae Wen" uniqKey="Kuo N" first="Nae-Wen" last="Kuo">Nae-Wen Kuo</name>
</noRegion>
<name sortKey="Chiang, Che Ming" sort="Chiang, Che Ming" uniqKey="Chiang C" first="Che-Ming" last="Chiang">Che-Ming Chiang</name>
<name sortKey="Chiang, Hsin Chen" sort="Chiang, Hsin Chen" uniqKey="Chiang H" first="Hsin-Chen" last="Chiang">Hsin-Chen Chiang</name>
</country>
<country name="Taïwan"><noRegion><name sortKey="Kuo, Nae Wen" sort="Kuo, Nae Wen" uniqKey="Kuo N" first="Nae-Wen" last="Kuo">Nae-Wen Kuo</name>
</noRegion>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Sante/explor/SrasV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003A33 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 003A33 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Sante |area= SrasV1 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:5CB5AFED8FDF45698D30F4EA2E0E5DCF1B11E624 |texte= Development and application of an integrated indoor air quality audit to an international hotel building in Taiwan }}
This area was generated with Dilib version V0.6.33. |