Transport of Droplets Expelled by Coughing in Ventilated Rooms

Identifieur interne : 003863 ( Main/Exploration ); précédent : 003862; suivant : 003864

Transport of Droplets Expelled by Coughing in Ventilated Rooms

Auteurs : Wei Sun [République populaire de Chine] ; Jie Ji [République populaire de Chine]

Source :

RBID : ISTEX:48F2C5197389373D72E05E41C99A5CF6C9593ACC

English descriptors

Abstract

This study aims to understand the transport and dispersal of droplets produced by coughing in a ventilated room. Experiments were conducted to measure the initial velocity and the duration of a coughing burst. Computational fluid dynamics with a Eulerian—Lagrangian model was used to investigate the transport characteristics of evaporating droplets expelled into the ventilated room. The simulation results indicate that if expelled horizontally the droplets finally settle if their initial size is >100 μm, while if expelled upwards the droplets only settle if their initial size is ≥300 μm. Different ventilation set-ups vary in their ability to remove droplets produced by coughing. The mixing ventilation system has an almost equal efficiency for removing small passive droplets and the nuclei of droplets whose original size was 100 and 80 μm, respectively. For displacement ventilation, although it has high efficiency in removing small passive droplets, it has difficulty in removing the nuclei of large droplets. In the displacement system, small droplets show a two-zonal distribution in the room, but the nuclei of large droplets are subjected to gravitational force and tend to settle in the lower part of the room.

Url:
DOI: 10.1177/1420326X07084290


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Transport of Droplets Expelled by Coughing in Ventilated Rooms</title>
<author wicri:is="90%">
<name sortKey="Sun, Wei" sort="Sun, Wei" uniqKey="Sun W" first="Wei" last="Sun">Wei Sun</name>
</author>
<author wicri:is="90%">
<name sortKey="Ji, Jie" sort="Ji, Jie" uniqKey="Ji J" first="Jie" last="Ji">Jie Ji</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:48F2C5197389373D72E05E41C99A5CF6C9593ACC</idno>
<date when="2007" year="2007">2007</date>
<idno type="doi">10.1177/1420326X07084290</idno>
<idno type="url">https://api.istex.fr/ark:/67375/M70-L40ZQMHQ-4/fulltext.pdf</idno>
<idno type="wicri:Area/Istex/Corpus">001389</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">001389</idno>
<idno type="wicri:Area/Istex/Curation">001389</idno>
<idno type="wicri:Area/Istex/Checkpoint">001206</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">001206</idno>
<idno type="wicri:doubleKey">1420-326X:2007:Sun W:transport:of:droplets</idno>
<idno type="wicri:Area/Main/Merge">003A17</idno>
<idno type="wicri:Area/Main/Curation">003863</idno>
<idno type="wicri:Area/Main/Exploration">003863</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Transport of Droplets Expelled by Coughing in Ventilated Rooms</title>
<author wicri:is="90%">
<name sortKey="Sun, Wei" sort="Sun, Wei" uniqKey="Sun W" first="Wei" last="Sun">Wei Sun</name>
<affiliation wicri:level="1">
<country xml:lang="fr" wicri:curation="lc">République populaire de Chine</country>
<wicri:regionArea>Department of Thermal Science and Energy Engineering, University of Science and Technology of China, Hefei, Anhui 230027</wicri:regionArea>
<wicri:noRegion>Anhui 230027</wicri:noRegion>
</affiliation>
</author>
<author wicri:is="90%">
<name sortKey="Ji, Jie" sort="Ji, Jie" uniqKey="Ji J" first="Jie" last="Ji">Jie Ji</name>
<affiliation></affiliation>
<affiliation wicri:level="1">
<country wicri:rule="url">République populaire de Chine</country>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Indoor and Built Environment</title>
<idno type="ISSN">1420-326X</idno>
<idno type="eISSN">1423-0070</idno>
<imprint>
<publisher>Sage Publications</publisher>
<pubPlace>Sage UK: London, England</pubPlace>
<date type="published" when="2007-12">2007-12</date>
<biblScope unit="volume">16</biblScope>
<biblScope unit="issue">6</biblScope>
<biblScope unit="page" from="493">493</biblScope>
<biblScope unit="page" to="504">504</biblScope>
</imprint>
<idno type="ISSN">1420-326X</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">1420-326X</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="Teeft" xml:lang="en">
<term>Carrier phase</term>
<term>Displacement ventilation</term>
<term>Droplet</term>
<term>Environ</term>
<term>Evaporating</term>
<term>Evaporating droplets</term>
<term>Flow field</term>
<term>Large droplets</term>
<term>Lower part</term>
<term>Manikin</term>
<term>Original diameter</term>
<term>Original size</term>
<term>Relative humidity</term>
<term>Simulation</term>
<term>Source manikin</term>
<term>Ventilation system</term>
<term>Vertical distribution</term>
<term>Water vapor</term>
</keywords>
</textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">This study aims to understand the transport and dispersal of droplets produced by coughing in a ventilated room. Experiments were conducted to measure the initial velocity and the duration of a coughing burst. Computational fluid dynamics with a Eulerian—Lagrangian model was used to investigate the transport characteristics of evaporating droplets expelled into the ventilated room. The simulation results indicate that if expelled horizontally the droplets finally settle if their initial size is >100 μm, while if expelled upwards the droplets only settle if their initial size is ≥300 μm. Different ventilation set-ups vary in their ability to remove droplets produced by coughing. The mixing ventilation system has an almost equal efficiency for removing small passive droplets and the nuclei of droplets whose original size was 100 and 80 μm, respectively. For displacement ventilation, although it has high efficiency in removing small passive droplets, it has difficulty in removing the nuclei of large droplets. In the displacement system, small droplets show a two-zonal distribution in the room, but the nuclei of large droplets are subjected to gravitational force and tend to settle in the lower part of the room.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>République populaire de Chine</li>
</country>
</list>
<tree>
<country name="République populaire de Chine">
<noRegion>
<name sortKey="Sun, Wei" sort="Sun, Wei" uniqKey="Sun W" first="Wei" last="Sun">Wei Sun</name>
</noRegion>
<name sortKey="Ji, Jie" sort="Ji, Jie" uniqKey="Ji J" first="Jie" last="Ji">Jie Ji</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Sante/explor/SrasV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 003863 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 003863 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Sante
   |area=    SrasV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:48F2C5197389373D72E05E41C99A5CF6C9593ACC
   |texte=   Transport of Droplets Expelled by Coughing in Ventilated Rooms
}}

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Tue Apr 28 14:49:16 2020. Site generation: Sat Mar 27 22:06:49 2021