Abstract

Several studies have reported poor indoor air quality (IAQ) in day care centers (DCCs), and other studies have shown that children attending them have an increased risk of respiratory and gastrointestinal infections. The aim of this study was to investigate whether there is an association between ventilation in DCCs and sick leave among nursery children. Data on child sick leave within an 11‐week period were obtained for 635 children attending 20 DCCs. Ventilation measurements included three proxies of ventilation: air exchange rate (ACR) measured with the decay method, ACR measured by the perfluorocarbon tracer gas (PFT) method, and CO2 concentration measured over a 1‐week period. All but two DCCs had balanced mechanical ventilation system, which could explain the low CO2 levels measured. The mean concentration of CO2 was 643 ppm, exceeding 1000 ppm in only one DCC. A statistically significant inverse relationship between the number of sick days and ACR measured with the decay method was found for crude and adjusted analysis, with a 12% decrease in number of sick days per hour increase in ACR measured with the decay method. This study suggests a relationship between sick leave among nursery children and ventilation in DCCs, as measured with the decay method.

Url:
DOI: 10.1111/ina.12202


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Ventilation in day care centers and sick leave among nursery children</title>
<author>
<name sortKey="Kolarik, B" sort="Kolarik, B" uniqKey="Kolarik B" first="B." last="Kolarik">B. Kolarik</name>
</author>
<author>
<name sortKey="Andersen, Z Jovanovic" sort="Andersen, Z Jovanovic" uniqKey="Andersen Z" first="Z. Jovanovic" last="Andersen">Z. Jovanovic Andersen</name>
</author>
<author>
<name sortKey="Ibfelt, T" sort="Ibfelt, T" uniqKey="Ibfelt T" first="T." last="Ibfelt">T. Ibfelt</name>
</author>
<author>
<name sortKey="Engelund, E Hoj" sort="Engelund, E Hoj" uniqKey="Engelund E" first="E. Hoj" last="Engelund">E. Hoj Engelund</name>
</author>
<author>
<name sortKey="M Ller, E" sort="M Ller, E" uniqKey="M Ller E" first="E." last="M Ller">E. M Ller</name>
</author>
<author>
<name sortKey="Br Uner, E Vaclavik" sort="Br Uner, E Vaclavik" uniqKey="Br Uner E" first="E. Vaclavik" last="Br Uner">E. Vaclavik Br Uner</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:E66C7936390F458BA2C86E4689AA876A449E8233</idno>
<date when="2016" year="2016">2016</date>
<idno type="doi">10.1111/ina.12202</idno>
<idno type="url">https://api.istex.fr/ark:/67375/WNG-WS927TRN-L/fulltext.pdf</idno>
<idno type="wicri:Area/Istex/Corpus">001B46</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Corpus" wicri:corpus="ISTEX">001B46</idno>
<idno type="wicri:Area/Istex/Curation">001B46</idno>
<idno type="wicri:Area/Istex/Checkpoint">000001</idno>
<idno type="wicri:explorRef" wicri:stream="Istex" wicri:step="Checkpoint">000001</idno>
<idno type="wicri:doubleKey">0905-6947:2016:Kolarik B:ventilation:in:day</idno>
<idno type="wicri:Area/Main/Merge">001097</idno>
<idno type="wicri:Area/Main/Curation">001095</idno>
<idno type="wicri:Area/Main/Exploration">001095</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main">Ventilation in day care centers and sick leave among nursery children</title>
<author>
<name sortKey="Kolarik, B" sort="Kolarik, B" uniqKey="Kolarik B" first="B." last="Kolarik">B. Kolarik</name>
<affiliation wicri:level="4">
<country xml:lang="fr">Danemark</country>
<wicri:regionArea>Department of Construction and Health, Danish Building Research Institute, Aalborg University, Copenhagen</wicri:regionArea>
<placeName>
<settlement type="city">Copenhague</settlement>
<region type="région" nuts="2">Hovedstaden</region>
</placeName>
<orgName type="university">Université d'Aalborg</orgName>
</affiliation>
<affiliation wicri:level="4">
<orgName type="university">Université d'Aalborg</orgName>
<country>Danemark</country>
<placeName>
<settlement type="city">Aalborg</settlement>
<region nuts="2" type="region">Jutland du Nord</region>
</placeName>
</affiliation>
<affiliation wicri:level="1">
<country wicri:rule="url">Danemark</country>
</affiliation>
</author>
<author>
<name sortKey="Andersen, Z Jovanovic" sort="Andersen, Z Jovanovic" uniqKey="Andersen Z" first="Z. Jovanovic" last="Andersen">Z. Jovanovic Andersen</name>
<affiliation wicri:level="3">
<country xml:lang="fr">Danemark</country>
<wicri:regionArea>Department of Public Health, Center for Epidemiology and Screening, Copenhagen University, Copenhagen</wicri:regionArea>
<placeName>
<settlement type="city">Copenhague</settlement>
<region type="région" nuts="2">Hovedstaden</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Ibfelt, T" sort="Ibfelt, T" uniqKey="Ibfelt T" first="T." last="Ibfelt">T. Ibfelt</name>
<affiliation wicri:level="3">
<country xml:lang="fr">Danemark</country>
<wicri:regionArea>Departments of Infection Control and Clinical Microbiology, Copenhagen University Hospital (Rigshospitalet), Copenhagen</wicri:regionArea>
<placeName>
<settlement type="city">Copenhague</settlement>
<region type="région" nuts="2">Hovedstaden</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Engelund, E Hoj" sort="Engelund, E Hoj" uniqKey="Engelund E" first="E. Hoj" last="Engelund">E. Hoj Engelund</name>
<affiliation wicri:level="1">
<country xml:lang="fr">Danemark</country>
<wicri:regionArea>DHI, Hoersholm</wicri:regionArea>
<wicri:noRegion>Hoersholm</wicri:noRegion>
</affiliation>
</author>
<author>
<name sortKey="M Ller, E" sort="M Ller, E" uniqKey="M Ller E" first="E." last="M Ller">E. M Ller</name>
<affiliation wicri:level="4">
<country xml:lang="fr">Danemark</country>
<wicri:regionArea>Department of Construction and Health, Danish Building Research Institute, Aalborg University, Copenhagen</wicri:regionArea>
<placeName>
<settlement type="city">Copenhague</settlement>
<region type="région" nuts="2">Hovedstaden</region>
</placeName>
<orgName type="university">Université d'Aalborg</orgName>
</affiliation>
</author>
<author>
<name sortKey="Br Uner, E Vaclavik" sort="Br Uner, E Vaclavik" uniqKey="Br Uner E" first="E. Vaclavik" last="Br Uner">E. Vaclavik Br Uner</name>
<affiliation wicri:level="4">
<country xml:lang="fr">Danemark</country>
<wicri:regionArea>Department of Construction and Health, Danish Building Research Institute, Aalborg University, Copenhagen</wicri:regionArea>
<placeName>
<settlement type="city">Copenhague</settlement>
<region type="région" nuts="2">Hovedstaden</region>
</placeName>
<orgName type="university">Université d'Aalborg</orgName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j" type="main">Indoor Air</title>
<title level="j" type="alt">INDOOR AIR</title>
<idno type="ISSN">0905-6947</idno>
<idno type="eISSN">1600-0668</idno>
<imprint>
<biblScope unit="vol">26</biblScope>
<biblScope unit="issue">2</biblScope>
<biblScope unit="page" from="157">157</biblScope>
<biblScope unit="page" to="167">167</biblScope>
<biblScope unit="page-count">11</biblScope>
<date type="published" when="2016-04">2016-04</date>
</imprint>
<idno type="ISSN">0905-6947</idno>
</series>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0905-6947</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract">Several studies have reported poor indoor air quality (IAQ) in day care centers (DCCs), and other studies have shown that children attending them have an increased risk of respiratory and gastrointestinal infections. The aim of this study was to investigate whether there is an association between ventilation in DCCs and sick leave among nursery children. Data on child sick leave within an 11‐week period were obtained for 635 children attending 20 DCCs. Ventilation measurements included three proxies of ventilation: air exchange rate (ACR) measured with the decay method, ACR measured by the perfluorocarbon tracer gas (PFT) method, and CO2 concentration measured over a 1‐week period. All but two DCCs had balanced mechanical ventilation system, which could explain the low CO2 levels measured. The mean concentration of CO2 was 643 ppm, exceeding 1000 ppm in only one DCC. A statistically significant inverse relationship between the number of sick days and ACR measured with the decay method was found for crude and adjusted analysis, with a 12% decrease in number of sick days per hour increase in ACR measured with the decay method. This study suggests a relationship between sick leave among nursery children and ventilation in DCCs, as measured with the decay method.</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Danemark</li>
</country>
<region>
<li>Hovedstaden</li>
<li>Jutland du Nord</li>
</region>
<settlement>
<li>Aalborg</li>
<li>Copenhague</li>
</settlement>
<orgName>
<li>Université d'Aalborg</li>
</orgName>
</list>
<tree>
<country name="Danemark">
<region name="Hovedstaden">
<name sortKey="Kolarik, B" sort="Kolarik, B" uniqKey="Kolarik B" first="B." last="Kolarik">B. Kolarik</name>
</region>
<name sortKey="Andersen, Z Jovanovic" sort="Andersen, Z Jovanovic" uniqKey="Andersen Z" first="Z. Jovanovic" last="Andersen">Z. Jovanovic Andersen</name>
<name sortKey="Br Uner, E Vaclavik" sort="Br Uner, E Vaclavik" uniqKey="Br Uner E" first="E. Vaclavik" last="Br Uner">E. Vaclavik Br Uner</name>
<name sortKey="Engelund, E Hoj" sort="Engelund, E Hoj" uniqKey="Engelund E" first="E. Hoj" last="Engelund">E. Hoj Engelund</name>
<name sortKey="Ibfelt, T" sort="Ibfelt, T" uniqKey="Ibfelt T" first="T." last="Ibfelt">T. Ibfelt</name>
<name sortKey="Kolarik, B" sort="Kolarik, B" uniqKey="Kolarik B" first="B." last="Kolarik">B. Kolarik</name>
<name sortKey="Kolarik, B" sort="Kolarik, B" uniqKey="Kolarik B" first="B." last="Kolarik">B. Kolarik</name>
<name sortKey="M Ller, E" sort="M Ller, E" uniqKey="M Ller E" first="E." last="M Ller">E. M Ller</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Sante/explor/SrasV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001095 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 001095 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Sante
   |area=    SrasV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:E66C7936390F458BA2C86E4689AA876A449E8233
   |texte=   Ventilation in day care centers and sick leave among nursery children
}}

Wicri

This area was generated with Dilib version V0.6.33.
Data generation: Tue Apr 28 14:49:16 2020. Site generation: Sat Mar 27 22:06:49 2021