The effects of different frequency responses on sound quality judgments and speech intelligibility.

Identifieur interne : 001F12 ( Main/Exploration ); précédent : 001F11; suivant : 001F13

The effects of different frequency responses on sound quality judgments and speech intelligibility.

Auteurs : A. Gabrielsson [Suède] ; B N Schenkman ; B. Hagerman

Source :

RBID : pubmed:3398490

Descripteurs français

English descriptors

Abstract

Four speech programs and two music programs were reproduced using five different frequency responses: one flat and the others combinations of reductions at lower frequencies and/or increases at higher frequencies. Twelve hearing impaired (HI) and 8 normal hearing (NH) subjects listened monaurally to the reproductions at comfortable listening level and judged the sound quality on seven perceptual scales and a scale for total impression. Speech intelligibility was measured for phonetically balanced (PB) word lists and for sentences in noise. Significant differences among the reproductions appeared in practically all scales. The most preferred system was characterized by a flat response at lower frequencies and a 6 dB/octave increase thereafter. There were certain differences between the NH and HI listeners in the judgments of the other systems. The intelligibility of PB word lists did not differ among the systems, and the S/N threshold for the sentences in noise only distinguished the flat response as worse than all others for the HI listeners. There was little correspondence between intelligibility measures and sound quality measures. The latter provided more information and distinctions among systems.

DOI: 10.1044/jshr.3102.166
PubMed: 3398490


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">The effects of different frequency responses on sound quality judgments and speech intelligibility.</title>
<author>
<name sortKey="Gabrielsson, A" sort="Gabrielsson, A" uniqKey="Gabrielsson A" first="A" last="Gabrielsson">A. Gabrielsson</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Technical Audiology, Karolinska Institute, Stockholm.</nlm:affiliation>
<country>Suède</country>
<placeName>
<settlement type="city">Stockholm</settlement>
<region nuts="2">Svealand</region>
</placeName>
<wicri:orgArea>Department of Technical Audiology, Karolinska Institute</wicri:orgArea>
</affiliation>
</author>
<author>
<name sortKey="Schenkman, B N" sort="Schenkman, B N" uniqKey="Schenkman B" first="B N" last="Schenkman">B N Schenkman</name>
</author>
<author>
<name sortKey="Hagerman, B" sort="Hagerman, B" uniqKey="Hagerman B" first="B" last="Hagerman">B. Hagerman</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PubMed</idno>
<date when="1988">1988</date>
<idno type="RBID">pubmed:3398490</idno>
<idno type="pmid">3398490</idno>
<idno type="doi">10.1044/jshr.3102.166</idno>
<idno type="wicri:Area/Main/Corpus">001F16</idno>
<idno type="wicri:explorRef" wicri:stream="Main" wicri:step="Corpus" wicri:corpus="PubMed">001F16</idno>
<idno type="wicri:Area/Main/Curation">001F16</idno>
<idno type="wicri:explorRef" wicri:stream="Main" wicri:step="Curation">001F16</idno>
<idno type="wicri:Area/Main/Exploration">001F16</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en">The effects of different frequency responses on sound quality judgments and speech intelligibility.</title>
<author>
<name sortKey="Gabrielsson, A" sort="Gabrielsson, A" uniqKey="Gabrielsson A" first="A" last="Gabrielsson">A. Gabrielsson</name>
<affiliation wicri:level="3">
<nlm:affiliation>Department of Technical Audiology, Karolinska Institute, Stockholm.</nlm:affiliation>
<country>Suède</country>
<placeName>
<settlement type="city">Stockholm</settlement>
<region nuts="2">Svealand</region>
</placeName>
<wicri:orgArea>Department of Technical Audiology, Karolinska Institute</wicri:orgArea>
</affiliation>
</author>
<author>
<name sortKey="Schenkman, B N" sort="Schenkman, B N" uniqKey="Schenkman B" first="B N" last="Schenkman">B N Schenkman</name>
</author>
<author>
<name sortKey="Hagerman, B" sort="Hagerman, B" uniqKey="Hagerman B" first="B" last="Hagerman">B. Hagerman</name>
</author>
</analytic>
<series>
<title level="j">Journal of speech and hearing research</title>
<idno type="ISSN">0022-4685</idno>
<imprint>
<date when="1988" type="published">1988</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Adult (MeSH)</term>
<term>Female (MeSH)</term>
<term>Hearing Disorders (physiopathology)</term>
<term>Humans (MeSH)</term>
<term>Judgment (MeSH)</term>
<term>Male (MeSH)</term>
<term>Middle Aged (MeSH)</term>
<term>Sound (MeSH)</term>
<term>Speech Intelligibility (MeSH)</term>
</keywords>
<keywords scheme="KwdFr" xml:lang="fr">
<term>Adulte (MeSH)</term>
<term>Adulte d'âge moyen (MeSH)</term>
<term>Femelle (MeSH)</term>
<term>Humains (MeSH)</term>
<term>Intelligibilité de la parole (MeSH)</term>
<term>Jugement (MeSH)</term>
<term>Mâle (MeSH)</term>
<term>Son (physique) (MeSH)</term>
<term>Troubles de l'audition (physiopathologie)</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathologie" xml:lang="fr">
<term>Troubles de l'audition</term>
</keywords>
<keywords scheme="MESH" qualifier="physiopathology" xml:lang="en">
<term>Hearing Disorders</term>
</keywords>
<keywords scheme="MESH" xml:lang="en">
<term>Adult</term>
<term>Female</term>
<term>Humans</term>
<term>Judgment</term>
<term>Male</term>
<term>Middle Aged</term>
<term>Sound</term>
<term>Speech Intelligibility</term>
</keywords>
<keywords scheme="MESH" xml:lang="fr">
<term>Adulte</term>
<term>Adulte d'âge moyen</term>
<term>Femelle</term>
<term>Humains</term>
<term>Intelligibilité de la parole</term>
<term>Jugement</term>
<term>Mâle</term>
<term>Son (physique)</term>
</keywords>
</textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">Four speech programs and two music programs were reproduced using five different frequency responses: one flat and the others combinations of reductions at lower frequencies and/or increases at higher frequencies. Twelve hearing impaired (HI) and 8 normal hearing (NH) subjects listened monaurally to the reproductions at comfortable listening level and judged the sound quality on seven perceptual scales and a scale for total impression. Speech intelligibility was measured for phonetically balanced (PB) word lists and for sentences in noise. Significant differences among the reproductions appeared in practically all scales. The most preferred system was characterized by a flat response at lower frequencies and a 6 dB/octave increase thereafter. There were certain differences between the NH and HI listeners in the judgments of the other systems. The intelligibility of PB word lists did not differ among the systems, and the S/N threshold for the sentences in noise only distinguished the flat response as worse than all others for the HI listeners. There was little correspondence between intelligibility measures and sound quality measures. The latter provided more information and distinctions among systems.</div>
</front>
</TEI>
<pubmed>
<MedlineCitation Status="MEDLINE" Owner="NLM">
<PMID Version="1">3398490</PMID>
<DateCompleted>
<Year>1988</Year>
<Month>09</Month>
<Day>08</Day>
</DateCompleted>
<DateRevised>
<Year>2019</Year>
<Month>08</Month>
<Day>28</Day>
</DateRevised>
<Article PubModel="Print">
<Journal>
<ISSN IssnType="Print">0022-4685</ISSN>
<JournalIssue CitedMedium="Print">
<Volume>31</Volume>
<Issue>2</Issue>
<PubDate>
<Year>1988</Year>
<Month>Jun</Month>
</PubDate>
</JournalIssue>
<Title>Journal of speech and hearing research</Title>
<ISOAbbreviation>J Speech Hear Res</ISOAbbreviation>
</Journal>
<ArticleTitle>The effects of different frequency responses on sound quality judgments and speech intelligibility.</ArticleTitle>
<Pagination>
<MedlinePgn>166-77</MedlinePgn>
</Pagination>
<Abstract>
<AbstractText>Four speech programs and two music programs were reproduced using five different frequency responses: one flat and the others combinations of reductions at lower frequencies and/or increases at higher frequencies. Twelve hearing impaired (HI) and 8 normal hearing (NH) subjects listened monaurally to the reproductions at comfortable listening level and judged the sound quality on seven perceptual scales and a scale for total impression. Speech intelligibility was measured for phonetically balanced (PB) word lists and for sentences in noise. Significant differences among the reproductions appeared in practically all scales. The most preferred system was characterized by a flat response at lower frequencies and a 6 dB/octave increase thereafter. There were certain differences between the NH and HI listeners in the judgments of the other systems. The intelligibility of PB word lists did not differ among the systems, and the S/N threshold for the sentences in noise only distinguished the flat response as worse than all others for the HI listeners. There was little correspondence between intelligibility measures and sound quality measures. The latter provided more information and distinctions among systems.</AbstractText>
</Abstract>
<AuthorList CompleteYN="Y">
<Author ValidYN="Y">
<LastName>Gabrielsson</LastName>
<ForeName>A</ForeName>
<Initials>A</Initials>
<AffiliationInfo>
<Affiliation>Department of Technical Audiology, Karolinska Institute, Stockholm.</Affiliation>
</AffiliationInfo>
</Author>
<Author ValidYN="Y">
<LastName>Schenkman</LastName>
<ForeName>B N</ForeName>
<Initials>BN</Initials>
</Author>
<Author ValidYN="Y">
<LastName>Hagerman</LastName>
<ForeName>B</ForeName>
<Initials>B</Initials>
</Author>
</AuthorList>
<Language>eng</Language>
<PublicationTypeList>
<PublicationType UI="D016428">Journal Article</PublicationType>
<PublicationType UI="D013485">Research Support, Non-U.S. Gov't</PublicationType>
</PublicationTypeList>
</Article>
<MedlineJournalInfo>
<Country>United States</Country>
<MedlineTA>J Speech Hear Res</MedlineTA>
<NlmUniqueID>0376336</NlmUniqueID>
<ISSNLinking>0022-4685</ISSNLinking>
</MedlineJournalInfo>
<CitationSubset>IM</CitationSubset>
<MeshHeadingList>
<MeshHeading>
<DescriptorName UI="D000328" MajorTopicYN="N">Adult</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D005260" MajorTopicYN="N">Female</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006311" MajorTopicYN="N">Hearing Disorders</DescriptorName>
<QualifierName UI="Q000503" MajorTopicYN="N">physiopathology</QualifierName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D006801" MajorTopicYN="N">Humans</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D007600" MajorTopicYN="Y">Judgment</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008297" MajorTopicYN="N">Male</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D008875" MajorTopicYN="N">Middle Aged</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013016" MajorTopicYN="Y">Sound</DescriptorName>
</MeshHeading>
<MeshHeading>
<DescriptorName UI="D013065" MajorTopicYN="Y">Speech Intelligibility</DescriptorName>
</MeshHeading>
</MeshHeadingList>
</MedlineCitation>
<PubmedData>
<History>
<PubMedPubDate PubStatus="pubmed">
<Year>1988</Year>
<Month>6</Month>
<Day>1</Day>
</PubMedPubDate>
<PubMedPubDate PubStatus="medline">
<Year>1988</Year>
<Month>6</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>1</Minute>
</PubMedPubDate>
<PubMedPubDate PubStatus="entrez">
<Year>1988</Year>
<Month>6</Month>
<Day>1</Day>
<Hour>0</Hour>
<Minute>0</Minute>
</PubMedPubDate>
</History>
<PublicationStatus>ppublish</PublicationStatus>
<ArticleIdList>
<ArticleId IdType="pubmed">3398490</ArticleId>
<ArticleId IdType="doi">10.1044/jshr.3102.166</ArticleId>
</ArticleIdList>
</PubmedData>
</pubmed>
<affiliations>
<list>
<country>
<li>Suède</li>
</country>
<region>
<li>Svealand</li>
</region>
<settlement>
<li>Stockholm</li>
</settlement>
</list>
<tree>
<noCountry>
<name sortKey="Hagerman, B" sort="Hagerman, B" uniqKey="Hagerman B" first="B" last="Hagerman">B. Hagerman</name>
<name sortKey="Schenkman, B N" sort="Schenkman, B N" uniqKey="Schenkman B" first="B N" last="Schenkman">B N Schenkman</name>
</noCountry>
<country name="Suède">
<region name="Svealand">
<name sortKey="Gabrielsson, A" sort="Gabrielsson, A" uniqKey="Gabrielsson A" first="A" last="Gabrielsson">A. Gabrielsson</name>
</region>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Sante/explor/SanteMusiqueV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 001F12 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 001F12 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Sante
   |area=    SanteMusiqueV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     pubmed:3398490
   |texte=   The effects of different frequency responses on sound quality judgments and speech intelligibility.
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Main/Exploration/RBID.i   -Sk "pubmed:3398490" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd   \
       | NlmPubMed2Wicri -a SanteMusiqueV1 

Wicri

This area was generated with Dilib version V0.6.38.
Data generation: Mon Mar 8 15:23:44 2021. Site generation: Mon Mar 8 15:23:58 2021