Serveur d'exploration sur la maladie de Parkinson

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Comparison of a timed motor test battery to the Unified Parkinson's Disease Rating Scale‐III in Parkinson's disease

Identifieur interne : 000E39 ( Main/Exploration ); précédent : 000E38; suivant : 000E40

Comparison of a timed motor test battery to the Unified Parkinson's Disease Rating Scale‐III in Parkinson's disease

Auteurs : Charlotte A. Haaxma [Pays-Bas] ; Bastiaan R. Bloem [Pays-Bas] ; George F. Borm [Pays-Bas] ; Martin W. I. M. Horstink [Pays-Bas]

Source :

RBID : ISTEX:85770F5CB724E62689D2EC62237AB1C110FF6D80

English descriptors

Abstract

The most widely used scale currently available for the clinical evaluation of motor dysfunction in Parkinson's disease (PD)—the Unified Parkinson's Disease Rating Scale‐III (UPDRS‐III) —is time‐consuming, subjective, and has suboptimal sensitivity. A brief timed motor test (TMT) battery could possibly overcome these drawbacks. Two hundred eighty‐eight PD patients (disease duration 3.1 years; preceding dopaminergic treatment initiation) were assessed with the UPDRS‐III and nine TMTs based on aspects of (a) walking, (b) writing, (c) single and double‐handed pegboard performance, (d) finger tapping, and (e) rapid alternating forearm movements. We investigated validity, reliability, responsiveness, and feasibility. Completing the TMT battery took less than 5 minutes. The TMT correlated well with UPDRS‐III and disease duration. Two factors explained 61% of the TMT variance, the first represented mainly upper extremity function, the second mainly axial/lower extremity function. Cronbach's α was equal for the TMT and the UPDRS‐III (0.8). Test–retest reliability of the TMT sumscore was 0.93 to 0.89 for measurements separated by 3 up to 24 months, whereas UPDRS‐III correlations were 0.88 to 0.84. At group level, a trial using “change from baseline” as endpoint requires only 75% of the patients needed with the UPDRS‐III when applying the TMT battery, and 57% using the pegboard dexterity test. At patient level, TMT and UPDRS‐III were equally responsive. The TMT battery described here is valid, reliable, and feasible. Compared to the UPDRS‐III, it is more objective and more sensitive to change. Therefore, it could be a useful tool for both practical and scientific purposes. © 2008 Movement Disorder Society

Url:
DOI: 10.1002/mds.22197


Affiliations:


Links toward previous steps (curation, corpus...)


Le document en format XML

<record>
<TEI wicri:istexFullTextTei="biblStruct">
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Comparison of a timed motor test battery to the Unified Parkinson's Disease Rating Scale‐III in Parkinson's disease</title>
<author>
<name sortKey="Haaxma, Charlotte A" sort="Haaxma, Charlotte A" uniqKey="Haaxma C" first="Charlotte A." last="Haaxma">Charlotte A. Haaxma</name>
</author>
<author>
<name sortKey="Bloem, Bastiaan R" sort="Bloem, Bastiaan R" uniqKey="Bloem B" first="Bastiaan R." last="Bloem">Bastiaan R. Bloem</name>
</author>
<author>
<name sortKey="Borm, George F" sort="Borm, George F" uniqKey="Borm G" first="George F." last="Borm">George F. Borm</name>
</author>
<author>
<name sortKey="Horstink, Martin W I M" sort="Horstink, Martin W I M" uniqKey="Horstink M" first="Martin W. I. M." last="Horstink">Martin W. I. M. Horstink</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:85770F5CB724E62689D2EC62237AB1C110FF6D80</idno>
<date when="2008" year="2008">2008</date>
<idno type="doi">10.1002/mds.22197</idno>
<idno type="url">https://api.istex.fr/document/85770F5CB724E62689D2EC62237AB1C110FF6D80/fulltext/pdf</idno>
<idno type="wicri:Area/Main/Corpus">000A02</idno>
<idno type="wicri:Area/Main/Curation">000874</idno>
<idno type="wicri:Area/Main/Exploration">000E39</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title level="a" type="main" xml:lang="en">Comparison of a timed motor test battery to the Unified Parkinson's Disease Rating Scale‐III in Parkinson's disease</title>
<author>
<name sortKey="Haaxma, Charlotte A" sort="Haaxma, Charlotte A" uniqKey="Haaxma C" first="Charlotte A." last="Haaxma">Charlotte A. Haaxma</name>
<affiliation wicri:level="3">
<country xml:lang="fr">Pays-Bas</country>
<wicri:regionArea>Department of Neurology, Radboud University Nijmegen Medical Centre, Nijmegen</wicri:regionArea>
<placeName>
<settlement type="city">Nimègue</settlement>
<region type="province" nuts="2">Gueldre</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Bloem, Bastiaan R" sort="Bloem, Bastiaan R" uniqKey="Bloem B" first="Bastiaan R." last="Bloem">Bastiaan R. Bloem</name>
<affiliation wicri:level="3">
<country xml:lang="fr">Pays-Bas</country>
<wicri:regionArea>Department of Neurology, Radboud University Nijmegen Medical Centre, Nijmegen</wicri:regionArea>
<placeName>
<settlement type="city">Nimègue</settlement>
<region type="province" nuts="2">Gueldre</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Borm, George F" sort="Borm, George F" uniqKey="Borm G" first="George F." last="Borm">George F. Borm</name>
<affiliation wicri:level="3">
<country xml:lang="fr">Pays-Bas</country>
<wicri:regionArea>Department of Epidemiology and Biostatistics, Radboud University Nijmegen Medical Centre, Nijmegen</wicri:regionArea>
<placeName>
<settlement type="city">Nimègue</settlement>
<region type="province" nuts="2">Gueldre</region>
</placeName>
</affiliation>
</author>
<author>
<name sortKey="Horstink, Martin W I M" sort="Horstink, Martin W I M" uniqKey="Horstink M" first="Martin W. I. M." last="Horstink">Martin W. I. M. Horstink</name>
<affiliation wicri:level="3">
<country xml:lang="fr">Pays-Bas</country>
<wicri:regionArea>Department of Neurology, Radboud University Nijmegen Medical Centre, Nijmegen</wicri:regionArea>
<placeName>
<settlement type="city">Nimègue</settlement>
<region type="province" nuts="2">Gueldre</region>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series>
<title level="j">Movement Disorders</title>
<title level="j" type="sub">Official Journal of the Movement Disorder Society</title>
<title level="j" type="abbrev">Mov. Disord.</title>
<idno type="ISSN">0885-3185</idno>
<idno type="eISSN">1531-8257</idno>
<imprint>
<publisher>Wiley Subscription Services, Inc., A Wiley Company</publisher>
<pubPlace>Hoboken</pubPlace>
<date type="published" when="2008-09-15">2008-09-15</date>
<biblScope unit="volume">23</biblScope>
<biblScope unit="issue">12</biblScope>
<biblScope unit="page" from="1707">1707</biblScope>
<biblScope unit="page" to="1717">1717</biblScope>
</imprint>
<idno type="ISSN">0885-3185</idno>
</series>
<idno type="istex">85770F5CB724E62689D2EC62237AB1C110FF6D80</idno>
<idno type="DOI">10.1002/mds.22197</idno>
<idno type="ArticleID">MDS22197</idno>
</biblStruct>
</sourceDesc>
<seriesStmt>
<idno type="ISSN">0885-3185</idno>
</seriesStmt>
</fileDesc>
<profileDesc>
<textClass>
<keywords scheme="KwdEn" xml:lang="en">
<term>Parkinson's disease</term>
<term>UPDRS</term>
<term>metric attributes</term>
<term>rating scales</term>
<term>timed motor tests</term>
</keywords>
</textClass>
<langUsage>
<language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">The most widely used scale currently available for the clinical evaluation of motor dysfunction in Parkinson's disease (PD)—the Unified Parkinson's Disease Rating Scale‐III (UPDRS‐III) —is time‐consuming, subjective, and has suboptimal sensitivity. A brief timed motor test (TMT) battery could possibly overcome these drawbacks. Two hundred eighty‐eight PD patients (disease duration 3.1 years; preceding dopaminergic treatment initiation) were assessed with the UPDRS‐III and nine TMTs based on aspects of (a) walking, (b) writing, (c) single and double‐handed pegboard performance, (d) finger tapping, and (e) rapid alternating forearm movements. We investigated validity, reliability, responsiveness, and feasibility. Completing the TMT battery took less than 5 minutes. The TMT correlated well with UPDRS‐III and disease duration. Two factors explained 61% of the TMT variance, the first represented mainly upper extremity function, the second mainly axial/lower extremity function. Cronbach's α was equal for the TMT and the UPDRS‐III (0.8). Test–retest reliability of the TMT sumscore was 0.93 to 0.89 for measurements separated by 3 up to 24 months, whereas UPDRS‐III correlations were 0.88 to 0.84. At group level, a trial using “change from baseline” as endpoint requires only 75% of the patients needed with the UPDRS‐III when applying the TMT battery, and 57% using the pegboard dexterity test. At patient level, TMT and UPDRS‐III were equally responsive. The TMT battery described here is valid, reliable, and feasible. Compared to the UPDRS‐III, it is more objective and more sensitive to change. Therefore, it could be a useful tool for both practical and scientific purposes. © 2008 Movement Disorder Society</div>
</front>
</TEI>
<affiliations>
<list>
<country>
<li>Pays-Bas</li>
</country>
<region>
<li>Gueldre</li>
</region>
<settlement>
<li>Nimègue</li>
</settlement>
</list>
<tree>
<country name="Pays-Bas">
<region name="Gueldre">
<name sortKey="Haaxma, Charlotte A" sort="Haaxma, Charlotte A" uniqKey="Haaxma C" first="Charlotte A." last="Haaxma">Charlotte A. Haaxma</name>
</region>
<name sortKey="Bloem, Bastiaan R" sort="Bloem, Bastiaan R" uniqKey="Bloem B" first="Bastiaan R." last="Bloem">Bastiaan R. Bloem</name>
<name sortKey="Borm, George F" sort="Borm, George F" uniqKey="Borm G" first="George F." last="Borm">George F. Borm</name>
<name sortKey="Horstink, Martin W I M" sort="Horstink, Martin W I M" uniqKey="Horstink M" first="Martin W. I. M." last="Horstink">Martin W. I. M. Horstink</name>
</country>
</tree>
</affiliations>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/ParkinsonV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000E39 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000E39 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Wicri/Sante
   |area=    ParkinsonV1
   |flux=    Main
   |étape=   Exploration
   |type=    RBID
   |clé=     ISTEX:85770F5CB724E62689D2EC62237AB1C110FF6D80
   |texte=   Comparison of a timed motor test battery to the Unified Parkinson's Disease Rating Scale‐III in Parkinson's disease
}}

Wicri

This area was generated with Dilib version V0.6.23.
Data generation: Sun Jul 3 18:06:51 2016. Site generation: Wed Mar 6 18:46:03 2024