Effect of stimulation frequency on immediate freezing of gait in newly activated STN DBS in Parkinson's disease
Identifieur interne : 000043 ( Main/Exploration ); précédent : 000042; suivant : 000044Effect of stimulation frequency on immediate freezing of gait in newly activated STN DBS in Parkinson's disease
Auteurs : Tao Xie [États-Unis] ; Un Jung Kang [États-Unis] ; Peter Warnke [États-Unis]Source :
- Journal of Neurology, Neurosurgery & Psychiatry [ 0022-3050 ] ; 2012-10.
Abstract
Background Patients with Parkinson's disease (PD) may develop freezing of gait (FOG) with chronic deep brain stimulation (DBS) of the subthalamic nucleus (STN) at the commonly used frequency of 130 Hz and FOG can be ameliorated by 60 Hz stimulation in some patients. It is not clear whether the development of FOG is due to the disease progression or the chronic stimulation at this 130 Hz frequency. Aims To investigate the effect of stimulation frequency on immediate FOG in newly activated STN DBS patient with PD and determine if stimulation frequency alone could affect the FOG. Methods Two cases of PD who developed FOG immediately upon activation of the newly placed STN DBS were studied for the effect of stimulation frequency on FOG in both `off' and `on' medication status. Results Both patients developed severe FOG with the commonly used 130 Hz stimulation. Switching the frequency to 60 Hz immediately alleviated the FOG, without change in contacts, voltages and pulse widths. This frequency effect on FOG was present in both `off' and `on' statuses and remained effective during the 10-month follow-up period. Conclusion These two cases demonstrate that lower frequency stimulation of 60 Hz could improve FOG, while the commonly used 130 Hz stimulation could cause FOG or make it worse. In addition, the beneficial effect of low frequency DBS was additive to dopaminergic medication effect and included other axial symptoms.
Url:
DOI: 10.1136/jnnp-2011-302091
Affiliations:
Links toward previous steps (curation, corpus...)
Le document en format XML
<record><TEI wicri:istexFullTextTei="biblStruct"><teiHeader><fileDesc><titleStmt><title>Effect of stimulation frequency on immediate freezing of gait in newly activated STN DBS in Parkinson's disease</title>
<author><name sortKey="Xie, Tao" sort="Xie, Tao" uniqKey="Xie T" first="Tao" last="Xie">Tao Xie</name>
</author>
<author><name sortKey="Kang, Un Jung" sort="Kang, Un Jung" uniqKey="Kang U" first="Un Jung" last="Kang">Un Jung Kang</name>
</author>
<author><name sortKey="Warnke, Peter" sort="Warnke, Peter" uniqKey="Warnke P" first="Peter" last="Warnke">Peter Warnke</name>
</author>
</titleStmt>
<publicationStmt><idno type="wicri:source">ISTEX</idno>
<idno type="RBID">ISTEX:DB803897F3B3535C220C39AD1C9EA513232DB602</idno>
<date when="2012" year="2012">2012</date>
<idno type="doi">10.1136/jnnp-2011-302091</idno>
<idno type="url">https://api.istex.fr/document/DB803897F3B3535C220C39AD1C9EA513232DB602/fulltext/pdf</idno>
<idno type="wicri:Area/Main/Corpus">002362</idno>
<idno type="wicri:Area/Main/Curation">002040</idno>
<idno type="wicri:Area/Main/Exploration">000043</idno>
</publicationStmt>
<sourceDesc><biblStruct><analytic><title level="a">Effect of stimulation frequency on immediate freezing of gait in newly activated STN DBS in Parkinson's disease</title>
<author><name sortKey="Xie, Tao" sort="Xie, Tao" uniqKey="Xie T" first="Tao" last="Xie">Tao Xie</name>
<affiliation wicri:level="2"><country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Neurology, University of Chicago Medical Center, Chicago, Illinois</wicri:regionArea>
<placeName><region type="state">Illinois</region>
</placeName>
</affiliation>
<affiliation wicri:level="1"><country wicri:rule="url">États-Unis</country>
</affiliation>
</author>
<author><name sortKey="Kang, Un Jung" sort="Kang, Un Jung" uniqKey="Kang U" first="Un Jung" last="Kang">Un Jung Kang</name>
<affiliation wicri:level="2"><country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Neurology, University of Chicago Medical Center, Chicago, Illinois</wicri:regionArea>
<placeName><region type="state">Illinois</region>
</placeName>
</affiliation>
</author>
<author><name sortKey="Warnke, Peter" sort="Warnke, Peter" uniqKey="Warnke P" first="Peter" last="Warnke">Peter Warnke</name>
<affiliation wicri:level="2"><country xml:lang="fr">États-Unis</country>
<wicri:regionArea>Department of Neurosurgery, University of Chicago Medical Center, Chicago, Illinois</wicri:regionArea>
<placeName><region type="state">Illinois</region>
</placeName>
</affiliation>
</author>
</analytic>
<monogr></monogr>
<series><title level="j">Journal of Neurology, Neurosurgery & Psychiatry</title>
<title level="j" type="abbrev">J Neurol Neurosurg Psychiatry</title>
<idno type="ISSN">0022-3050</idno>
<idno type="eISSN">1468-330X</idno>
<imprint><publisher>BMJ Publishing Group Ltd</publisher>
<date type="published" when="2012-10">2012-10</date>
<biblScope unit="volume">83</biblScope>
<biblScope unit="issue">10</biblScope>
<biblScope unit="page" from="1015">1015</biblScope>
</imprint>
<idno type="ISSN">0022-3050</idno>
</series>
<idno type="istex">DB803897F3B3535C220C39AD1C9EA513232DB602</idno>
<idno type="DOI">10.1136/jnnp-2011-302091</idno>
<idno type="href">jnnp-83-1015.pdf</idno>
<idno type="ArticleID">jnnp-2011-302091</idno>
<idno type="PMID">22696586</idno>
<idno type="local">jnnp;83/10/1015</idno>
</biblStruct>
</sourceDesc>
<seriesStmt><idno type="ISSN">0022-3050</idno>
</seriesStmt>
</fileDesc>
<profileDesc><textClass></textClass>
<langUsage><language ident="en">en</language>
</langUsage>
</profileDesc>
</teiHeader>
<front><div type="abstract">Background Patients with Parkinson's disease (PD) may develop freezing of gait (FOG) with chronic deep brain stimulation (DBS) of the subthalamic nucleus (STN) at the commonly used frequency of 130 Hz and FOG can be ameliorated by 60 Hz stimulation in some patients. It is not clear whether the development of FOG is due to the disease progression or the chronic stimulation at this 130 Hz frequency. Aims To investigate the effect of stimulation frequency on immediate FOG in newly activated STN DBS patient with PD and determine if stimulation frequency alone could affect the FOG. Methods Two cases of PD who developed FOG immediately upon activation of the newly placed STN DBS were studied for the effect of stimulation frequency on FOG in both `off' and `on' medication status. Results Both patients developed severe FOG with the commonly used 130 Hz stimulation. Switching the frequency to 60 Hz immediately alleviated the FOG, without change in contacts, voltages and pulse widths. This frequency effect on FOG was present in both `off' and `on' statuses and remained effective during the 10-month follow-up period. Conclusion These two cases demonstrate that lower frequency stimulation of 60 Hz could improve FOG, while the commonly used 130 Hz stimulation could cause FOG or make it worse. In addition, the beneficial effect of low frequency DBS was additive to dopaminergic medication effect and included other axial symptoms.</div>
</front>
</TEI>
<affiliations><list><country><li>États-Unis</li>
</country>
<region><li>Illinois</li>
</region>
</list>
<tree><country name="États-Unis"><region name="Illinois"><name sortKey="Xie, Tao" sort="Xie, Tao" uniqKey="Xie T" first="Tao" last="Xie">Tao Xie</name>
</region>
<name sortKey="Kang, Un Jung" sort="Kang, Un Jung" uniqKey="Kang U" first="Un Jung" last="Kang">Un Jung Kang</name>
<name sortKey="Warnke, Peter" sort="Warnke, Peter" uniqKey="Warnke P" first="Peter" last="Warnke">Peter Warnke</name>
<name sortKey="Xie, Tao" sort="Xie, Tao" uniqKey="Xie T" first="Tao" last="Xie">Tao Xie</name>
</country>
</tree>
</affiliations>
</record>
Pour manipuler ce document sous Unix (Dilib)
EXPLOR_STEP=$WICRI_ROOT/Wicri/Sante/explor/ParkinsonV1/Data/Main/Exploration
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000043 | SxmlIndent | more
Ou
HfdSelect -h $EXPLOR_AREA/Data/Main/Exploration/biblio.hfd -nk 000043 | SxmlIndent | more
Pour mettre un lien sur cette page dans le réseau Wicri
{{Explor lien |wiki= Wicri/Sante |area= ParkinsonV1 |flux= Main |étape= Exploration |type= RBID |clé= ISTEX:DB803897F3B3535C220C39AD1C9EA513232DB602 |texte= Effect of stimulation frequency on immediate freezing of gait in newly activated STN DBS in Parkinson's disease }}
This area was generated with Dilib version V0.6.23. |