Serveur d'exploration sur les pandémies grippales

Attention, ce site est en cours de développement !
Attention, site généré par des moyens informatiques à partir de corpus bruts.
Les informations ne sont donc pas validées.

Fit Assessment of N95 Filtering-Facepiece Respirators in the U.S. Centers for Disease Control and Prevention Strategic National Stockpile

Identifieur interne : 000894 ( Pmc/Corpus ); précédent : 000893; suivant : 000895

Fit Assessment of N95 Filtering-Facepiece Respirators in the U.S. Centers for Disease Control and Prevention Strategic National Stockpile

Auteurs : Michael Bergman ; Ziqing Zhuang ; Elizabeth Brochu ; Andrew Palmiero

Source :

RBID : PMC:4752193

Abstract

National Institute for Occupational Safety and Health (NIOSH)-approved N95 filtering-facepiece respirators (FFR) are currently stockpiled by the U.S. Centers for Disease Control and Prevention (CDC) for emergency deployment to healthcare facilities in the event of a widespread emergency such as an influenza pandemic. This study assessed the fit of N95 FFRs purchased for the CDC Strategic National Stockpile. The study addresses the question of whether the fit achieved by specific respirator sizes relates to facial size categories as defined by two NIOSH fit test panels. Fit test data were analyzed from 229 test subjects who performed a nine-donning fit test on seven N95 FFR models using a quantitative fit test protocol. An initial respirator model selection process was used to determine if the subject could achieve an adequate fit on a particular model; subjects then tested the adequately fitting model for the nine-donning fit test. Only data for models which provided an adequate initial fit (through the model selection process) for a subject were analyzed for this study. For the nine-donning fit test, six of the seven respirator models accommodated the fit of subjects (as indicated by geometric mean fit factor > 100) for not only the intended NIOSH bivariate and PCA panel sizes corresponding to the respirator size, but also for other panel sizes which were tested for each model. The model which showed poor performance may not be accurately represented because only two subjects passed the initial selection criteria to use this model. Findings are supportive of the current selection of facial dimensions for the new NIOSH panels. The various FFR models selected for the CDC Strategic National Stockpile provide a range of sizing options to fit a variety of facial sizes.


Url:
PubMed: 26877587
PubMed Central: 4752193

Links to Exploration step

PMC:4752193

Le document en format XML

<record>
<TEI>
<teiHeader>
<fileDesc>
<titleStmt>
<title xml:lang="en">Fit Assessment of N95 Filtering-Facepiece Respirators in the U.S. Centers for Disease Control and Prevention Strategic National Stockpile</title>
<author>
<name sortKey="Bergman, Michael" sort="Bergman, Michael" uniqKey="Bergman M" first="Michael" last="Bergman">Michael Bergman</name>
</author>
<author>
<name sortKey="Zhuang, Ziqing" sort="Zhuang, Ziqing" uniqKey="Zhuang Z" first="Ziqing" last="Zhuang">Ziqing Zhuang</name>
</author>
<author>
<name sortKey="Brochu, Elizabeth" sort="Brochu, Elizabeth" uniqKey="Brochu E" first="Elizabeth" last="Brochu">Elizabeth Brochu</name>
</author>
<author>
<name sortKey="Palmiero, Andrew" sort="Palmiero, Andrew" uniqKey="Palmiero A" first="Andrew" last="Palmiero">Andrew Palmiero</name>
</author>
</titleStmt>
<publicationStmt>
<idno type="wicri:source">PMC</idno>
<idno type="pmid">26877587</idno>
<idno type="pmc">4752193</idno>
<idno type="url">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4752193</idno>
<idno type="RBID">PMC:4752193</idno>
<date when="2015">2015</date>
<idno type="wicri:Area/Pmc/Corpus">000894</idno>
<idno type="wicri:explorRef" wicri:stream="Pmc" wicri:step="Corpus" wicri:corpus="PMC">000894</idno>
</publicationStmt>
<sourceDesc>
<biblStruct>
<analytic>
<title xml:lang="en" level="a" type="main">Fit Assessment of N95 Filtering-Facepiece Respirators in the U.S. Centers for Disease Control and Prevention Strategic National Stockpile</title>
<author>
<name sortKey="Bergman, Michael" sort="Bergman, Michael" uniqKey="Bergman M" first="Michael" last="Bergman">Michael Bergman</name>
</author>
<author>
<name sortKey="Zhuang, Ziqing" sort="Zhuang, Ziqing" uniqKey="Zhuang Z" first="Ziqing" last="Zhuang">Ziqing Zhuang</name>
</author>
<author>
<name sortKey="Brochu, Elizabeth" sort="Brochu, Elizabeth" uniqKey="Brochu E" first="Elizabeth" last="Brochu">Elizabeth Brochu</name>
</author>
<author>
<name sortKey="Palmiero, Andrew" sort="Palmiero, Andrew" uniqKey="Palmiero A" first="Andrew" last="Palmiero">Andrew Palmiero</name>
</author>
</analytic>
<series>
<title level="j">Journal of the International Society for Respiratory Protection</title>
<idno type="ISSN">0892-6298</idno>
<imprint>
<date when="2015">2015</date>
</imprint>
</series>
</biblStruct>
</sourceDesc>
</fileDesc>
<profileDesc>
<textClass></textClass>
</profileDesc>
</teiHeader>
<front>
<div type="abstract" xml:lang="en">
<p id="P1">National Institute for Occupational Safety and Health (NIOSH)-approved N95 filtering-facepiece respirators (FFR) are currently stockpiled by the U.S. Centers for Disease Control and Prevention (CDC) for emergency deployment to healthcare facilities in the event of a widespread emergency such as an influenza pandemic. This study assessed the fit of N95 FFRs purchased for the CDC Strategic National Stockpile. The study addresses the question of whether the fit achieved by specific respirator sizes relates to facial size categories as defined by two NIOSH fit test panels. Fit test data were analyzed from 229 test subjects who performed a nine-donning fit test on seven N95 FFR models using a quantitative fit test protocol. An initial respirator model selection process was used to determine if the subject could achieve an adequate fit on a particular model; subjects then tested the adequately fitting model for the nine-donning fit test. Only data for models which provided an adequate initial fit (through the model selection process) for a subject were analyzed for this study. For the nine-donning fit test, six of the seven respirator models accommodated the fit of subjects (as indicated by geometric mean fit factor > 100) for not only the intended NIOSH bivariate and PCA panel sizes corresponding to the respirator size, but also for other panel sizes which were tested for each model. The model which showed poor performance may not be accurately represented because only two subjects passed the initial selection criteria to use this model. Findings are supportive of the current selection of facial dimensions for the new NIOSH panels. The various FFR models selected for the CDC Strategic National Stockpile provide a range of sizing options to fit a variety of facial sizes.</p>
</div>
</front>
</TEI>
<pmc article-type="research-article">
<pmc-comment>The publisher of this article does not allow downloading of the full text in XML form.</pmc-comment>
<pmc-dir>properties manuscript</pmc-dir>
<front>
<journal-meta>
<journal-id journal-id-type="nlm-journal-id">9514024</journal-id>
<journal-id journal-id-type="pubmed-jr-id">44431</journal-id>
<journal-id journal-id-type="nlm-ta">J Int Soc Respir Prot</journal-id>
<journal-id journal-id-type="iso-abbrev">J Int Soc Respir Prot</journal-id>
<journal-title-group>
<journal-title>Journal of the International Society for Respiratory Protection</journal-title>
</journal-title-group>
<issn pub-type="ppub">0892-6298</issn>
</journal-meta>
<article-meta>
<article-id pub-id-type="pmid">26877587</article-id>
<article-id pub-id-type="pmc">4752193</article-id>
<article-id pub-id-type="manuscript">HHSPA757673</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Fit Assessment of N95 Filtering-Facepiece Respirators in the U.S. Centers for Disease Control and Prevention Strategic National Stockpile</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Bergman</surname>
<given-names>Michael</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Zhuang</surname>
<given-names>Ziqing</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Brochu</surname>
<given-names>Elizabeth</given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Palmiero</surname>
<given-names>Andrew</given-names>
</name>
</contrib>
<aff id="A1">National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, PA</aff>
</contrib-group>
<author-notes>
<corresp id="CR1">Corresponding author
<email>vzb3@cdc.gov</email>
</corresp>
</author-notes>
<pub-date pub-type="nihms-submitted">
<day>6</day>
<month>2</month>
<year>2016</year>
</pub-date>
<pub-date pub-type="ppub">
<year>2015</year>
</pub-date>
<pub-date pub-type="pmc-release">
<day>12</day>
<month>2</month>
<year>2016</year>
</pub-date>
<volume>32</volume>
<issue>2</issue>
<fpage>50</fpage>
<lpage>64</lpage>
<abstract>
<p id="P1">National Institute for Occupational Safety and Health (NIOSH)-approved N95 filtering-facepiece respirators (FFR) are currently stockpiled by the U.S. Centers for Disease Control and Prevention (CDC) for emergency deployment to healthcare facilities in the event of a widespread emergency such as an influenza pandemic. This study assessed the fit of N95 FFRs purchased for the CDC Strategic National Stockpile. The study addresses the question of whether the fit achieved by specific respirator sizes relates to facial size categories as defined by two NIOSH fit test panels. Fit test data were analyzed from 229 test subjects who performed a nine-donning fit test on seven N95 FFR models using a quantitative fit test protocol. An initial respirator model selection process was used to determine if the subject could achieve an adequate fit on a particular model; subjects then tested the adequately fitting model for the nine-donning fit test. Only data for models which provided an adequate initial fit (through the model selection process) for a subject were analyzed for this study. For the nine-donning fit test, six of the seven respirator models accommodated the fit of subjects (as indicated by geometric mean fit factor > 100) for not only the intended NIOSH bivariate and PCA panel sizes corresponding to the respirator size, but also for other panel sizes which were tested for each model. The model which showed poor performance may not be accurately represented because only two subjects passed the initial selection criteria to use this model. Findings are supportive of the current selection of facial dimensions for the new NIOSH panels. The various FFR models selected for the CDC Strategic National Stockpile provide a range of sizing options to fit a variety of facial sizes.</p>
</abstract>
<kwd-group>
<kwd>Respirator Fit</kwd>
<kwd>N95 Filtering Facepiece Respirators</kwd>
<kwd>Strategic National Stockpile</kwd>
<kwd>Respirator Fit Test Panel</kwd>
</kwd-group>
</article-meta>
</front>
</pmc>
</record>

Pour manipuler ce document sous Unix (Dilib)

EXPLOR_STEP=$WICRI_ROOT/Sante/explor/PandemieGrippaleV1/Data/Pmc/Corpus
HfdSelect -h $EXPLOR_STEP/biblio.hfd -nk 000894 | SxmlIndent | more

Ou

HfdSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd -nk 000894 | SxmlIndent | more

Pour mettre un lien sur cette page dans le réseau Wicri

{{Explor lien
   |wiki=    Sante
   |area=    PandemieGrippaleV1
   |flux=    Pmc
   |étape=   Corpus
   |type=    RBID
   |clé=     PMC:4752193
   |texte=   Fit Assessment of N95 Filtering-Facepiece Respirators in the U.S. Centers for Disease Control and Prevention Strategic National Stockpile
}}

Pour générer des pages wiki

HfdIndexSelect -h $EXPLOR_AREA/Data/Pmc/Corpus/RBID.i   -Sk "pubmed:26877587" \
       | HfdSelect -Kh $EXPLOR_AREA/Data/Pmc/Corpus/biblio.hfd   \
       | NlmPubMed2Wicri -a PandemieGrippaleV1 

Wicri

This area was generated with Dilib version V0.6.34.
Data generation: Wed Jun 10 11:04:28 2020. Site generation: Sun Mar 28 09:10:28 2021